Home | Products | Comparison of Ti Series for Electrical/Mechanical
|
|
|
|
|
|
|
|
|
|
|
 |
| | |  | | |  |  | | | Fluke Ti100 Series Thermal Imagers
| |
 |
 |
 |
| |
Ti100 |
Ti110 |
Ti125 |
ResolutionThe higher, the better |
160 x 120 |
160 x 120 |
160 x 120 |
Temp. measurement range |
-4 °F to +482 °F (-20 °C to +250 °C ) |
-4 °F to +482 °F (-20 °C to +250 °C ) |
-4 °F to +662 °F (-20 °C to +350 °C ) |
Thermal sensitivity (NETD) The lower, the better |
= 0.10 °C at 30 °C target temp (100 mK) |
= 0.10 °C at 30 °C target temp (100 mK) |
= 0.10 °C at 30 °C target temp (100 mK) |
IR-Fusion® viewing mode |
IR only |
Full IR, picture-in-picture |
Full IR, picture-in-picture , AutoBlend™ |
Emissivity correction |
- |
On-board |
On-board |
Voice annotation |
- |
Yes |
Yes |
Optional lenses |
- |
- |
- |
Battery |
Field replaceable, rechargeable (1) |
Field replaceable, rechargeable (1) |
Field replaceable, rechargeable (2) |
Fluke P3 Series Thermal Imagers for Electrical / Mechanical
| |
 |
 |
 |
| |
Ti27 |
Ti29 |
Ti32 |
ResolutionThe higher, the better |
240 x 180 |
280 x 210 |
320 x 240 |
Temp. measurement range |
-4 °F to +1112 °F |
-4 °F to +1112 °F |
-4 °F to +1112 °F |
Thermal sensitivity (NETD) The lower, the better |
= 0.05 °C (50 mK) |
= 0.05 °C (50 mK) |
= 0.045 °C (45 mK) |
IR-Fusion® viewing mode |
Full IR, picture-in-picture, blending |
Full IR, picture-in-picture, blending |
Full IR, picture-in-picture, blending |
Emissivity correction |
On-board |
On-board |
On-board |
Voice annotation |
Yes |
Yes |
Yes |
Optional lenses |
Yes |
Yes |
Yes |
Battery |
Replaceable (2) |
Replaceable (2) |
Replaceable (2) |
Fluke Ti Series Thermal Imagers for Electrical / Mechanical
Product Comparison
This comparison table highlights the key differences between the models. Use our Product Selection Tool to view a complete spec-by-spec comparison.
| |
|
 |
 |
| |
Ti9
| Ti10 |
Ti25 |
ResolutionThe higher, the better |
160 x 120 |
160 x 120 |
160 x 120 |
Temp. measurement range |
-4°F to +482°F |
-4°F to +482°F |
-4°F to +662°F |
Thermal sensitivity (NETD) The lower, the better |
=0.2 °C (200mk) |
=0.2 °C (200mk) |
=0.1 °C (100mk) |
IR-Fusion® viewing mode |
IR Only |
Full IR, picture-in-picture |
Full IR, picture-in-picture, blending |
Emissivity correction |
In-software only |
In-software only |
On-board |
Voice annotation |
- |
- |
Yes |
Optional lenses |
- |
- |
- |
Battery |
Internal |
Internal |
Internal |