| | |  | | |  |  | | | Fluke Ti100 Series Thermal Imagers
| |
|
 |
 |
| |
Ti100 |
TiR110 |
TiR125 |
ResolutionThe higher, the better |
160 x 120 |
160 x 120 |
160 x 120 |
Temp. measurement range |
-20 °C to +250 °C (-4 °F to +482 °F) |
-20 °C to +150 °C (-4 °F to +302 °F) |
-20 °C to +150 °C (-4 °F to +302 °F) |
Thermal sensitivity (NETD)The lower, the better |
= 0.10 °C at 30 °C target temp (100 mK) |
= 0.08 °C at 30 °C target temp (80 mK) |
= 0.08 °C at 30 °C target temp (80 mK) |
IR-Fusion® viewing modes |
IR only |
Full IR, picture-in-picture |
Full IR, picture-in-picture, AutoBlend™ |
Color palettes |
4 |
11 |
16 |
Voice annotation |
- |
Yes |
Yes |
Level and span |
Manual and auto |
Manual and auto |
Manual and auto |
Dew point alarm |
Yes |
- |
Yes |
Optional lenses |
- |
- |
- |
Battery |
Field replaceable, rechargeable (1) |
Field replaceable, rechargeable (1) |
Field replaceable, rechargeable (2) |
Fluke P3 Series Thermal Imagers for Buildings Comparison
| |
|
 |
 |
| |
TiR27 |
TiR29 |
TiR32 |
ResolutionThe higher, the better |
240 x 180 |
280 x 210 |
320 x 240 |
Temp. measurement range |
-4 °F to +302 °F |
-4 °F to +302 °F |
-4 °F to +302 °F |
Thermal sensitivity (NETD)The lower, the better |
= 0.045 °C (45 mK) |
= 0.045 °C (45 mK) |
= 0.04 °C (40 mK) |
IR-Fusion® viewing modes |
Full IR, picture-in-picture, blending |
Full IR, picture-in-picture, blending |
Full IR, picture-in-picture, blending |
Emissivity correction |
On-board |
On-board |
On-board |
Voice annotation |
Yes |
Yes |
Yes |
Optional lenses |
Yes |
Yes |
Yes |
Battery |
Replaceable (2) |
Replaceable (2) |
Replaceable (2) |
Fluke Ti Series Thermal Imagers for Buildings Comparison
Product Comparison
This comparison table highlights the key differences between the models. Use our Product Selection Tool to view a complete spec-by-spec comparison.
| |
|
 |
 |
| |
TiS |
TiR |
TiR1 |
ResolutionThe higher, the better |
120 x 120 |
160 x 120 |
160 x 120 |
Temp. measurement range |
-4°F to +212°F |
-4°F to +212°F |
-4°F to +212°F |
Thermal sensitivity (NETD)The lower, the better |
=0.1 °C (100mk) |
=0.1 °C (100mk) |
=0.07 °C (70mk) |
IR-Fusion® viewing modes |
IR Only |
Full IR, picture-in-picture |
Full IR, picture-in-picture, blending |
Color palettes |
3 |
4 |
6 |
Voice annotation |
- |
- |
Yes |
Level and span |
Auto and lock only |
Auto/manual |
Auto/manual |
Dew point alarm |
- |
- |
- |
Optional lenses |
- |
- |
- |
Battery |
Internal |
Internal |
Internal |
« Return to Thermal Imagers for Buildings | |
|
|
|
|
|
|
|
|
|
|
|