The most trusted tools in the world
Home  |  Products  |  Process Calibration Tools  |  mA Loop Calibrators  |  

Fluke 709H Precision Loop Calibrator with HART Communications / Diagnostics

Fluke 709H Precision HART Loop Calibrator
Fluke 709H Precision HART Loop Calibrator
Fluke 709H Precision HART Loop Calibrator
Fluke 709H Precision HART Loop Calibrator
The Fluke 709H mA loop calibrator is designed to save time and produce high-quality results. The 709H offers HART communication and supports a select set of the HART universal and common practice commands. This makes the 709H unique as both an affordable, compact loop calibrator and powerful HART communication tool.
The Fluke 709H calibrator is built around a user friendly interface with a Quick-Set rotary encoder knob. This tool reduces the time it takes to measure, or source, voltage or current and power up a loop. The protective holster easily fits into a technician’s hand and the large backlit display is easy to read, even in dark, cramped worked areas.  The 709H offers:

  • Best-in-class accuracy at 0.01% reading
  • Small rugged design operates on (6) standard AAA batteries
  • Intuitive user interface with Quick-Set knob for fast setup, easy use
  • Built in selectable 250 Ω resistor for HART communication
  • 24 V DC loop power with mA Measure Mode (-25% to 125%)
  • Resolution of 1 µA on mA ranges and 1 mV on voltages ranges
  • Simple two wire connection for all measurements
  • Auto Shutdown to conserve battery life (adjustable up to 30 minutes)
  • Variable step & ramp time in seconds
  • Adjustable span selection (0 to 20 mA or 4 to 20 mA)
  • Valve Test (simulate defined mA values with % keys)
HART specific capabilities include:
  • Fast transfer of calibration data.  The 709H/Track software/cable documents the parameters of all the HART transmitters in your plant, in either (.csv) or (.txt) format.
  • Data logging or recording data on a particular transmitter for troubleshooting.  The data log tool offers selectable capture interval from 1 to 60 seconds and a logging capacity of 9800 records or 99 individual sessions. Each data sample contains the 709H measurement, all four process variables, and the standard status conditions.
Fluke 709H Precision HART Loop Calibrator with built-in 250 ohm resistor 

In the communicator mode the user will be able to read basic device information, perform diagnostic tests, and trim the calibration on most HART enabled transmitters. In the past, this could only be done with a dedicated communicator, a high-end multifunction calibrator, or a laptop computer with HART modem. Fluke 709H will allow virtually any technician to service and support HART devices.

Detailed Specifications
Functions mA source, mA simulate, mA read, mA read/loop power, and volts read.
Ranges mA (0 to 24mA) and Volts (0 to 30VDC)
Resolution 1 µA on mA ranges and 1 mV on voltage range
Accuracy 0.01% +/- 2 counts, all ranges (@23° +/- 5°C)
Operating Temperature Range -10 °C to 55 °C  (14 °F to 131°F)
Humidity Range 10 to 95% non-condensing
Stability 20 ppm of F.S. /°C from -10°C to 18°C and 28°C to 55°C
Display 128 x 64 pixels, LCD Graphic w/backlight, .34 high digits
Power 6 AAA alkaline
Battery Life 40 hours typical
Loop Compliance Voltage 24VDC @ 20mA
Over-Voltage Protection 240 VAC
Overload Current Protection 28 mA DC
EMC EN61326 Annex A (Portable Instruments)
Dimensions (L x W x D) 15 cm x 9 cm x 3 cm  (6 x 3.6 x 1.3)
Weight 0.3 kg  (9.5 ounces)
Included Accessories NIST traceable calibration certificate with data, batteries, test leads, and manual
Warranty Three year
Model NameDescriptionBuy it
Fluke 709H

Fluke 709H Precision Current Loop Calibrator with HART Communications/Diagnostics including:

  • 754-8016 Alligator Clip Set
  • 75X-8014 Stackable Lead Set
  • TP220-4201 Test Probes
  • AC280-5001 SureGrip Hook Clips
  • Soft Case
  • Six AAA batteries (installed)
  • Product Manual CD-ROM
  • Quick Reference Guide
  • Safety Information
 

HART communication

The Fluke 709H offers a built-in HART modem for communication capability to perform the following commands:
  • Read Message
  • Read Tag, Descriptor, Cal Date
  • Read Sensor PV Info
  • Read PV Output Info
  • Read Long Tag
  • Write PV Ranges (Upper and Lower)
  • Enter/Exit Fixed Current Mode
  • Set Zero Offset
  • Trim DAC Zero
  • Trim DAC Gain

The Fluke 709H also offers ability to store up to twenty HART device configuration files for uploading via 709H/Track software. Configurations can be stored as .csv or .txt files. This allows the end user to document the entire plant for HART devices without spending thousands of dollars for plant asset management software.


CarePlansBuy it
G3P-Group2
  • GOLD CarePlan.
  • Models covered: 50 Series II (51 II, 52 II, 53 II, 54 II), 190 Series II (190-062/AM, 190-062/AM/S, 190-102/AM, 190-102/AM/S, 190-104/AM, 190-104/AM/S, 190-202/AM, 190-202/AM/S, 190-204/AM, 190-204/AM/S, 190-502/AM, 190-502/AM/S), 381, 705, 707, 709, 709H, 712, 714, 715, 717, 718, 719, 754, 787, 789, 810, 1550C, 1577, and 1587.
  • Extends warranty from three to five years and includes five annual NIST traceable calibrations with data.
 
S3P-Group2
  • SILVER CarePlan.
  • Models covered: 50 Series II (51 II, 52 II, 53 II, 54 II), 190 Series II (190-062/AM, 190-062/AM/S, 190-102/AM, 190-102/AM/S, 190-104/AM, 190-104/AM/S, 190-202/AM, 190-202/AM/S, 190-204/AM, 190-204/AM/S, 190-502/AM, 190-502/AM/S), 381, 705, 707, 709, 709H, 712, 714, 715, 717, 718, 719, 754, 787, 789, 810, 1550C, 1577, and 1587.
  • Extends warranty from three to five years.

ClipsBuy it
AC220AC220 SureGrip™ Alligator Clips
AC280AC280 SureGrip™ Hook Clips
AC283AC283 SureGrip™ Pincer Clips
AC285AC285 SureGrip™ Alligator Clips
AC87AC87 Heavy Duty Bus Bar Clip Set
AC89AC89 Heavy Duty Insulation Piercing Test Clip

Test ProbesBuy it
TP38TP 38 Slim Reach Test Probe Set
TP1TP1 Slim Reach Test Probes
TP2TP2 Slim Reach Test Probes
TP220TP220 SureGrip™ Industrial Test Probes
TP4TP4 Slim Reach Test Probes
TP74TP74 Lantern Tip Test Probes
TP80TP80 Electronic Test Probes

SoftwareBuy it
Fluke 709H/TrackFluke 709H/Track HART Communications Software
  • Fluke 709H/Track Software
  • Lemo/USB Communications Cable
  •   

    Cases and HolstersBuy it
    C100C100 Universal Carrying Case
    C12AC12A Meter Case
    C195C195 Case
    C25Large Soft Case for DMMs
    C800C800 Meter and Accessory Case

    Test Leads, Probes and ClipsBuy it
    TL80ATL80A Basic Electronic Test Lead Kit

    PressureBuy it
    PV350PV350 Pressure Vacuum Module

    TemperatureBuy it
    80T-150UA80T-150UA Universal Temperature Probe
    80TK80TK Thermocouple Module

    Test LeadsBuy it
    TL220TL220 SureGrip™ Industrial Test Lead Set
    TL221TL221 SureGrip™ Test Lead Extension Set
    TL223TL223 SureGrip™ Electrical Test Lead Set
    TL224TL224 SureGrip™ Insulated Test Leads
    TL238TL238 SureGrip™ Test Lead Set for High Energy Environments
    TL26ATL26A 60 in. 5-Way Test Lead Set
    TL27TL27 Heavy Duty Test Lead Set
    TL28ATL28A Automotive Test Lead Set
    TL71TL71 Premium Test Lead Set
    TL75TL75 Hard Point™ Test Lead Set
    TL76TL76 2mm/4mm Test Lead Set
    TL81ATL81A Deluxe Electronic Test Lead Kit
            
    Related Products

    5 reviews
     
     Fluke 754 Documenting Process Calibrator-HART  »
    Home   |   Site Map   |   Fluke Corporation   |   Safety Notices  |   Terms and Conditions   |   Privacy Statement   |   Disclaimer © 1995 - 2013 Fluke Corporation