The Fluke 705 Loop Calibrator is a cost-effective, integrated solution for calibration, repair and maintenance of current loops. It features:
- mA sourcing, simulation and measurement
- 0.02% accuracy and 0.001 mA resolution
- Simultaneous mA and % of span display
- Selectable step or ramp outputs
- 24 V Loop supply with mA measure
- 0-28 VDC measurement to check Loop Voltage
- Easy battery exchange without opening the case
- Compact case with separate protective holster
- Three year warranty
|
|
Low cost calibrator muscle.
For a powerful loop calibrator at a very affordable price, choose the new Fluke 705 Loop Calibrator. This feature-rich solution to loop calibration, maintenance and repair offers:
- A large display and simple, pushbutton interface for ease of use.
- Simultaneous mA and % readout for quick, easy interpretation of readings.
- mA accuracy of 0.02%
- Push button 25% steps for fast, easy linearity checks. Save time over traditional knob type controls.
- "Span Check" for fast confirmation of zero and span.
- Selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.
- 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
- Single 9V battery that is easily changed.
- 0 - 20 mA or 4 - 20 mA default start up modes.
|
Safety conformance
CSA C22.2 No. 1010.1:1992
|
| Specifications |
| Current Measurement |
| Range: |
0 to 24 mA |
| Resolution: |
0.001 mA |
| Accuracy: |
0.02% Rdg + 2 LSD |
| | Current Sourcing |
| Range: |
0 to 20 mA or 4 to 20 mA |
| Accuracy: |
0.025% Rdg + 2 LSD |
| Drive Capability: |
1000 Ω @ 24 mA |
| | Current Simulation |
| Range: |
0 to 20 mA or 4 to 20 mA |
| Accuracy: |
0.025% Rdg + 2 LSD |
| Ext. loop voltage requirement: |
12-30 V |
| | Loop Power | | | Voltage measurement |
| Range: |
0 to 28 V DC |
| Resolution: |
1 mV |
| Accuracy: |
0.025% Rdg + 2 LSD |
|
| Environmental Specifications |
| Operating Temperature | | | Storage Temperature | | | Humidity (Without Condensation) |
|
0 to 90% (0 ºC to 35 ºC); 0 to 70% (35 ºC to 55 ºC) |
| | Temperature Coefficient |
|
-10 ºC to 18 ºC, 28 ºC to 55 ºC, ±.005% of range per ºC |
|
| Safety Specifications |
| Safety |
|
CSA C22.2 No. 1010.1:1992 |
| | EMC |
|
EN50082-1:1992 and EN55022:1994 Class B |
| | Maximum voltage | |
| Mechanical & General Specifications |
| Size | | | Weight | | | Batteries | | | Warranty | | | Shock & Vibration |
|
per MIL-T-28800 for a Class 2 Instrument |
| | Display current and % of span | | | Auto step, auto ramp | | | Span Check | |
|
| Model Name | Description | Price List | Buy it | | Fluke 705 |
Loop Calibrator including:
- AC70A Alligator Clips
- C10 protective yellow holster with Flex-Stand™
- Instruction sheet
- TL75 safety-designed test lead set
- NIST- traceable calibration report and data
|
|  | |
| CarePlans | Buy it | | G3P-Group2 |
- GOLD CarePlan.
- Models covered: 50 Series II (51 II, 52 II, 53 II, 54 II), 190 Series II (190-062/AM, 190-062/AM/S, 190-102/AM, 190-102/AM/S, 190-104/AM, 190-104/AM/S, 190-202/AM, 190-202/AM/S, 190-204/AM, 190-204/AM/S, 190-502/AM, 190-502/AM/S), 381, 705, 707, 709, 709H, 712, 714, 715, 717, 718, 719, 754, 787, 789, 810, 1550C, 1577, and 1587.
- Extends warranty from three to five years and includes five annual NIST traceable calibrations with data.
| |  | | S3P-Group2 |
- SILVER CarePlan.
- Models covered: 50 Series II (51 II, 52 II, 53 II, 54 II), 190 Series II (190-062/AM, 190-062/AM/S, 190-102/AM, 190-102/AM/S, 190-104/AM, 190-104/AM/S, 190-202/AM, 190-202/AM/S, 190-204/AM, 190-204/AM/S, 190-502/AM, 190-502/AM/S), 381, 705, 707, 709, 709H, 712, 714, 715, 717, 718, 719, 754, 787, 789, 810, 1550C, 1577, and 1587.
- Extends warranty from three to five years.
|  |  |
| Cases and Holsters | Buy it | | C10 | C10 Meter Holster |  |  |
| Clips | Buy it | | AC220 | AC220 SureGrip™ Alligator Clips |  |  | | AC280 | AC280 SureGrip™ Hook Clips |  |  | | AC283 | AC283 SureGrip™ Pincer Clips |  |  | | AC285 | AC285 SureGrip™ Alligator Clips |  |  | | AC87 | AC87 Heavy Duty Bus Bar Clip Set |  |  | | AC89 | AC89 Heavy Duty Insulation Piercing Test Clip |  |  |
| Test Probes | Buy it | | TP38 | TP 38 Slim Reach Test Probe Set |  |  | | TP1 | TP1 Slim Reach Test Probes |  |  | | TP2 | TP2 Slim Reach Test Probes |  |  | | TP220 | TP220 SureGrip™ Industrial Test Probes |  |  | | TP4 | TP4 Slim Reach Test Probes |  |  | | TP74 | TP74 Lantern Tip Test Probes |  |  | | TP80 | TP80 Electronic Test Probes |  |  |
| Cases and Holsters | Buy it | | C100 | C100 Universal Carrying Case |  |  | | C12A | C12A Meter Case |  |  | | C195 | C195 Case |  |  | | C25 | Large Soft Case for DMMs |  |  | | C800 | C800 Meter and
Accessory Case
|  |  |
| Test Leads, Probes and Clips | Buy it | | TL80A | TL80A Basic Electronic Test Lead Kit |  |  |
| Pressure | Buy it | | PV350 | PV350 Pressure Vacuum Module |  |  |
| Temperature | Buy it | | 80T-150UA | 80T-150UA Universal Temperature Probe |  |  | | 80TK | 80TK Thermocouple Module |  |  |
| Test Leads | Buy it | | TL220 | TL220 SureGrip™ Industrial Test Lead Set |  |  | | TL221 | TL221 SureGrip™ Test Lead Extension Set |  |  | | TL223 | TL223 SureGrip™ Electrical Test Lead Set |  |  | | TL224 | TL224 SureGrip™ Insulated Test Leads |  |  | | TL238 | TL238 SureGrip™ Test Lead Set for High Energy Environments |  |  | | TL26A | TL26A 60 in. 5-Way Test Lead Set |  |  | | TL27 | TL27 Heavy Duty Test Lead Set |  |  | | TL28A | TL28A Automotive Test Lead Set |  |  | | TL71 | TL71 Premium Test Lead Set |  |  | | TL75 | TL75 Hard Point™ Test Lead Set |  |  | | TL76 | TL76 2mm/4mm Test Lead Set |  |  | | TL81A | TL81A Deluxe Electronic Test Lead Kit |  |  |
|
|
|
|
|
|
|
|
|
|
|
|
| | |