Take a new look at current measurement
With the striking design of the Fluke 330 Series, we've taken a new look at the way you make current measurements. At how you use your tools, and how to get the results you need, faster and more conveniently. The result is a new, ergonomic concept, shaped to fit your hand and to access tight spots easily. The series feature a large display that is backlit -on most models- so readings can be taken in virtually any lighting situation. Auto-shut-off maximizes battery life so the meter works when you need it. A choice of five models gives you the right functions for your measurements.
|
Clamp meters that fit the way you work
- Three year warranty
- Small body and jaws fit perfectly in your hand and into tight places
- Handy 'Display Hold' button keeps measurements on the display
- Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch)
- Large, backlit display is easy-to-see in less than ideal conditions
- In-rush current function (on most models) for measuring starting current for motors, lighting, etc.
- Auto shut-off maximizes battery life so the meter works when you need it
- Improved low current measurement accuracy from new microprocessor technology
- Five different models to meet your exact needs
|
Models
- Fluke 333 - Rugged reliability at a basic price, measures ac amps, ac/dc volts and ohms
- Fluke 334 - Large display with backlight, measures ac amps, ac/dc volts, ohms and motor start-up current
- Fluke 335 - A True-rms clamp meter, large backlit display, measures ac amps, ac/dc volts, ohms and motor start-up current
- Fluke 336 - A True-rms clamp meter that measures ac/dc current and voltage, ohms, motor start-up current with large display and backlight
- Fluke 337 - The top-of the-line True-rms clamp meter, large jaw measures ac/dc current and voltage, ohm, motor start-up current (in-rush), frequency, MIN/MAX capability and a large backlit display
|
Safety conformance
IEC 1010-2-032, 600V CAT III
|
| Specifications |
| Voltage DC |
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts |
| | Voltage AC |
| Fluke 333/334 |
|
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts (50/60 Hz) |
| AC Response: |
Averaging |
| Fluke 335 |
|
| |
|
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts (50/60 Hz) |
| AC Response: |
True-rms |
| |
|
| Fluke 336/337 |
|
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts (20-100 Hz), 6% ± 5 counts (100-400 Hz) |
| AC Response: |
True-rms |
| | Current DC |
| Fluke 336 |
|
| Range: |
0 - 600.0 A |
| Accuracy: |
2% ± 5 counts |
|
|
| Fluke 337 |
|
| Range: |
0 - 999.9 A |
| Accuracy: |
2% ± 5 counts |
| | Current AC |
| Fluke 333 |
|
| Range: |
0 - 400.0 A |
| Accuracy: |
2% ± 5 counts (50/60 Hz) |
| AC Response: |
Averaging |
|
|
| Fluke 334 |
|
| Range: |
0 - 600.0 A |
| Accuracy: |
2% ± 5 counts (50/60 Hz) |
| AC Response |
Averaging |
|
|
| Fluke 335 |
|
| Range: |
0 - 600.0 A |
| Accuracy: |
2% ± 5 counts (50/60 Hz) |
| Crest Factor(50/60 Hz): |
2.4 @ 500A, 2.0 @ 600A, add 2% for CF>2 |
| AC Response: |
True-rms |
|
|
| Fluke 336 |
|
| Range: |
0 - 600.0 A |
| Accuracy: |
2% ± 5 counts (10-100 Hz), 6% ± 5 counts (100 - 400 Hz) |
| Crest Factor(50/60 Hz): |
3 @ 500A, 2.5 @ 600A, add 2% for CF>2 |
| AC Response: |
True-rms |
|
|
| Fluke 337 |
|
| Range: |
0 - 999.9 A |
| Accuracy: |
2% ± 5 counts (10-100 Hz), 6% ± 5 counts (100 - 400 Hz) |
| Crest Factor(50/60 Hz): |
3 @ 500A, 2.5 @ 600A, 1.42@1000 A, add 2% for CF>2 |
| AC Response: |
True-rms |
| | Resistance |
| Fluke 333 |
|
| Range: |
0 - 600.0 Ω |
| Accuracy: |
1.5% ± 5 counts |
|
|
| Fluke 334/335/336/337 |
|
| Range: |
0 - 600.0 Ω, 600 - 6000 Ω |
| Accuracy: |
1.5% ± 5 counts |
| | Frequency |
| Fluke 337 |
|
| Range: |
5 - 400Hz |
| Accuracy: |
0.5% ± 5 counts |
| Trigger Level: |
10-100 Hz >= 5A, 5-10 Hz, 100-400 Hz >=10A |
| | Inrush Current |
| Fluke 334/335/336/337 |
|
| Integration Time: |
100 ms |
| | Continuity | | | MIN/MAX | |
| Environmental Specifications |
| Operating Temperature |
|
-10 °C to +50 °C, -14 °F to 122 °F |
| | Storage Temperature |
|
-40ºC to +60ºC, -22 °F to 140 °F |
| | Operating Altitude |
|
2,500 meters max, 6,500 ft max |
| | Temperature De-rating |
|
Add 0.1 x specified accuracy for each ºC above 28ºC or below 18ºC (above 82.4°F or below 64.4°F) |
|
| Safety Specifications |
| Safety Rating |
|
IEC 1010-2-032, 600V CAT III |
|
| Mechanical & General Specifications |
| Size |
| Fluke 333/334/335 |
|
|
240mm x 80mm x 40mm (9.375" x 3.125" x 1.625") |
|
- |
| Fluke 336/337 |
|
|
250mm x 80mm x 40mm (9.875" x 3.125" x 1.625") |
| | Weight | | | Warranty | | | Battery Life |
|
Alkaline approximately 150 hours continuous |
|
Automatic low battery indicator |
| | Backlight | | | Display Hold | |
|
|
|
|