The market’s best multimeters just got better
The 280 Series: designed for those who need the best
The Fluke 287/289 true-RMS digital multimeters were designed for those of you at the top of your field. The instruments replace our popular 180 Series, with all the same features, plus more.
The two multimeters perform advanced unattended data logging, and show trend data on screen without having to download to a PC. TrendCapture helps engineers and technicians track down problems faster during (for example) preventive and predictive maintenance.
An extra-large screen shows results graphically, backed by an enhanced user interface with on-board help (i-info key) available in seven languages, and soft-key interface. Both meters can log multiple sessions unattended in the field, with logged readings being reviewed without a PC. Both come with a lifetime warranty.
Key features of the Fluke 287/289:
- 0.025% DC accuracy, 100 kHz
- AC bandwidth
- Large 50,000 count, 1/4 VGA dot matrix display
- Data logging function with expanded memory
- TrendCapture allows you to graphically review logged readings right on the meter, without needing a PC. Store, up to 15,000 readings over time
- Advanced Min/Max/Average – all the data on one screen, with start and elapsed time
- "i" button – provides on-board function help
- Lifetime warranty
|
In addition, the Fluke 289 features:
- Two terminal 50 Ω range with 1 mΩ resolution, 10 mA
- Low Pass filter for accurate voltage and frequency measurements on adjustable speed motor drives
- LoZ Volts. Low impedance voltage function for eliminating ghost voltages
|
Click here for more detailed features of both the Fluke 287 and Fluke 289
The two Fluke instruments feature a large 50,000-count, 3-1/2 inch quarter-VGA dot matrix display that can show multiple measurement sets. The screen also features a white backlight with 2 positions, and displays context-sensitive on-board help screens. The instrument setup is customizable to save time and increase productivity. Multiple save options and automatic time stamping allow convenient recall of field measurements, while a PC interface ensures easy data transfer. Optional FlukeView® Forms PC software enables users to document, store and analyze readings, and then convert them into professional-looking reports.
Measure true-rms voltage and current
Fluke’s meters store up to 15,000 readings. For accurate measurement on non-linear signals, they can measure true-rms voltage and current. They have a 50 mF capacitance range, and measure up to 10 A (or 20 A for 30 seconds). Peak capture can record transients as fast as 250 microseconds. A relative mode removes test lead resistance from low ohms or capacitance measurements. Both meters have a battery life of 200 hours.
The Fluke 287/289 has an ac bandwidth of 100 kHz, and a 0.025% basic dc accuracy. It includes a temperature function.
Fluke multimeters are known for their ruggedness, life time warranty, safety ratings, product life time and low total cost of ownership.
The Fluke 287/289 meters withstand hazardous 8,000 V spikes caused by load switching and faults on industrial circuits, and complies with second edition IEC and ANSI electrical safety standards. It diagnoses problems in electronics, plant automation, power distribution and electromechanical equipment.
FlukeView® Forms Combo Kits
Both Fluke 287 and Fluke 289 come in a special FlukeView® Forms Combo Kit. These kits contain software with cable and several accessories.
Fluke 287/FVF Kit Fluke 289/FVF Kit
|
|
Key Features Include:
- Large 50,000 count, ¼ VGA display with white backlight. Multiple sets of measurement information can simultaneously be displayed at the same time.
- Logging function with TrendCapture is an essential tool for documenting the performance of your designs, processes or systems, or unattended monitoring while you work on other projects. It plots measurements as a single line to help detect signal anomalies over time, storing up to 10,000 readings. Using on-board TrendCapture, you can graphically view logged readings without a PC. (Software and interface cable optional).
- Log multiple sessions or log data continuously for over 200 hours.
- i-info button. On board help screens for measurement functions. Unsure about a function? Go to that function and Press the “i” button.
- Now, name your saved measurements and also recall measurements made in the field
- Real Time Clock – for automatic time stamping of saved readings
- Field upgradeable and expandable meter lets you stay current as new capabilities are added
- Multi-lingual interface
- Min/Max/Average with Time Stamp to record signal fluctuations
- Soft keys, scroll buttons and easy navigation control access to secondary functions.
- 0.025% Basic DC accuracy
- 100 kHz ac bandwidth
- True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads.
- Measure up to 10A (20 A for 30 seconds; 10A continuous)
- 100 mF capacitance range
- Temperature function
- Relative mode to remove test lead resistance from low ohms or capacitance measurements
- Peak capture to record transients as fast as 250 μs
- Premium test leads and alligator clips included
- Optional FlukeView forms enables you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents
- Optional magnetic hanger allows you to hang the meter for easy viewing while freeing your hands to focus on the job.
- Limited lifetime warranty
- CAT III 1000 V / CAT IV 600 V safety rated
|
In addition, the Fluke 289 features:
- LoZ Volts. Low impedance voltage function prevents false readings due to “ghost voltage.” It is also the recommended mode when testing for absence or presence of live power.
- Low Pass Filter for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment.
- 50 ohm range – useful for measuring and comparing differences in motor winding resistance, low ohm measurements, or other contact resistance. Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current.
- Saved measurements allow you to name and recall measurements made in the field
- Optical USB PC communication interface allows for easy PC download to document logged data with FVF software (not included).
|
|
|
| Specifications |
| Voltage DC |
| Accuracy |
0.025 % |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
| | Voltage AC |
| Accuracy |
0.4 %(true-rms) |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
| | Current DC |
| Accuracy |
0.06 % |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| | Current AC |
| Accuracy |
0.61 %(true-rms) |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| | Temperature (excluding probe) |
| Accuracy |
1.0 % |
| Range and Resolution |
-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) |
| | Resistance |
| Accuracy |
0.05 % |
| Range and Resolution |
500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
| | Resistance 10 50 Ω (2 wire connection) |
| Accuracy |
0.15 % + 20 |
| Range and resolution |
50.000 Ω |
| | Capacitance |
| Accuracy |
1.0 % |
| Range and Resolution |
1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF,
100.00 mF Ω |
| | Frequency |
| Accuracy |
0.005% + 5 |
| Range and Resolution |
99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
| | Additional functions/features |
| Multiple on-screen displays |
Yes |
| True-rms AC bandwidth |
100 kHz |
| DBV/dBm |
Yes |
| DC mV resolution |
1 μV |
| Megohm range |
Up to 500 M |
| Conductance |
50.00nS |
| Continuity beeper |
Yes |
| Battery/Fuse access |
Battery / Fuse |
| Peak |
250 μS |
| Elapse time clock |
Yes |
| Time of day clock |
Yes |
| Min-Max-Avg |
Yes |
| Frequency |
Yes |
| Duty Cycle |
0.01 % to 99.99 % |
| Pulse Width |
0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms |
| Hold |
Yes |
| Isolated Optical Interface |
Yes |
| Auto/Touch Hold |
Yes |
| Reading memory |
Yes |
| Log to PC |
Yes |
| Interval/Event Logging |
Yes |
| Logging Memory |
Up to 10,000 readings |
| Resistance Low Ohm |
0.001 Ω to 50.000 Ω 10 mA source |
| LoZ |
Yes |
| Low Pass Filter |
Yes |
|
| Environmental Specifications |
| Operating Temperature | | | Storage Temperature | | | Relative Humidity |
|
0% to 90% (0 °C - 37 °C) |
|
0% to 65% (37 °C - 45 °C), |
|
0 to 45 % (45 °C - 55 °C |
| | Electromagnetic Compatability | | | Vibration |
|
Random vibration per MIL-PRF-28800f Class 2 |
| | Shock |
|
1 meter drop per IEC/EN 61010-1 2nd edition |
|
| Safety Specifications |
| Overvoltage category |
|
CAT III 1000 V / CAT IV 600 V safety rated |
| | Agency Approvals | |
| Mechanical & General Specifications |
| Maximum voltage between any terminal and earth ground | | | Size |
|
(HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in) |
| | Weight | | | Battery Life |
|
100 minimum, 200 hours in logging mode |
| | Battery type |
|
6 AA alkaline batteries, NEDA 15A IEC LR6 |
|
|
| |