United States [Change Country]  |  Fluke [Change Company]
fluke
Home  |  Products  |  Digital Multimeters  |  
Contact usRefer this page

Rugged Multimeters: Fluke 27 II/28 II Industrial Multimeters


 Fluke 27 II/28 II
The NEW standard for rugged

The NEW Fluke 27 II and 28 II digital multimeters define a new standard for operating in harsh conditions with the features and accuracy to troubleshoot most electrical problems. Both meters have IP 67 (waterproof and dustproof) rating, MSHA approvals, extended operating temperature range of -15 °C to +55 °C (5 °F to 131 °F, -40 °C for up to 20 minutes) and 95 % humidity, and have been designed and tested to withstand a 3 m (10 ft) drop. The new Fluke 20 Series Multimeters are built to work in the toughest environments.

  • Measure up to 1000 V ac and dc
  • Measure up to 10 A (20 A for 30 seconds)
  • 10,000 μF capacitance range
  • Frequency to 200 kHz
  • Extended ac voltage bandwidth– 15 Hz to 20 kHz (28 II), 40 Hz to 30 kHz (27 II)
  • Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (28 II)
  • Resistance, continuity and diode test
  • Min/Max and average recording to capture variations automatically
  • Peak min-max (28 II)
  • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (28 II)

Features:

  • New – IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments
  • Designed to withstand 3 meter drop (with holster)
  • Hi resolution 20,000 count display mode (28 II)
  • True-rms ac voltage and current for accurate measurements on non linear signals (28 II)
  • Average responding voltage and current for measurements (27 II)
  • New – Backlit keypad buttons allow for easy visibility in lowlit areas
  • Large display digits and 2 level bright white backlight for increased visibility
  • Reversible holster for added protection when not in use
  • Withstands hazardous 8,000 volt spikes caused by load switching and faults on industrial circuits and complies with second edition IEC and ANSI electrical safety standards
  • Long battery life (800 hours)
  • Relative mode to remove test lead resistance from low ohms measurements
  • Auto and manual ranging for maximum flexibility
  • Optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks
  • MSHA approval
Accuracy specifications
DC voltage
Range  0.1 mV to 1000 V
Accuracy  27-II:0.1 % +1
28-II:0.05 % + 1
AC voltage
Range  0.1 mV to 1000 V
Accuracy  27-II: 0.5 % +3
28-II: 0.7 % +4
DC current
Range  0.1 μA to 10 A
Accuracy  27-II: 0.2 % + 4
28-II: 0.2 % + 4
AC current
Range  0.1 μA to 10 A
Accuracy  27-II: 1.5 % + 2
28-II: 1.0 % + 2
Resistance
Range  0.1 Ω to 50 MΩ
Display counts
27-II  6000
28-II  6000/19,999
Capacitance
 1 nF to 9999 μF
Frequency
 0.5 Hz to 199.99 kHz
Temperature
 27-II: N/A
28-II: -200 °C to +1090 °C
Low pass filter (Measurement on VSD’s)
 27-II: N/A
28-II: Yes
Compliance
 CAT IV 600 V , CAT III 1000V
IP rating
27-II:  IP 67
28-II:  IP 67
Power
 Three AA batteries
Battery life
 800 hours

 

General specifications
Display
Bar graph/backlight  Yes/Yes
Data storage
Peak transient capture  250 μS (28 II)
Min/Max/Avg  Yes
Reading hold  Yes
Other features
Relative readings (zero)  Yes
Battery type  Three AA batteries
Warranty and protection
Safety rating  CAT IV 600 V/CAT III 1000 V
Mine Safety  MSHA Approved
External protection  Rubber holster
Drop test  10 feet drop test
Dustproof/waterproof  Yes, IP 67 rated
Warranty  Limited lifetime
Size (HxWxL) with holster  6.35 cm x 10.0 cm x 19.81 cm (2.5 in x 3.93 in x 7.8 in)
Weight with holster  698.5 g (1.54 lb)
Model NameDescriptionBuy it
FLUKE 27-IIIndustrial Multimeter  
FLUKE 28-IIIndustrial Multimeter  

Cases-HolstersBuy it
C100C100 Universal Carrying Case
C101C101 Hard Case
C125C125 Meter Case
C550C550 Tool Bag
CXT80CXT80 Extreme Case

Test Leads Probes and ClipsBuy it
AC285AC285 SureGrip™ Alligator Clips
TL220TL220 SureGrip™ Industrial Test Lead Set
TL71TL71 Premium Test Lead Set
TLK225TLK-225 SureGrip™ Master Accessory Set

Current ClampsBuy it
i1010i1010 AC/DC Current Clamp
i200i200 AC Current Clamp
i2000 flexi2000 flex AC Current Clamp
i3000si3000s AC Current Clamp
i400i400 AC Current Clamp
i410i410 AC/DC Current Clamp

TemperatureBuy it
80AK-A80AK-A Thermocouple Adapter
80PK-180PK-1 Bead Probe
80PK-2780PK-27 SureGrip™ Industrial Surface Temperature Probe
80PK-3A80PK-3A Surface Probe
80PK-880PK-8 Pipe Clamp Temperature Probe
80PK-980PK-9 General Purpose Probe
80PK-EXT80PK-EXT Extension Wire Kit
80T-150UA80T-150UA Universal Temperature Probe
80TK80TK Thermocouple Module

High-Voltage-ProbesBuy it
80k-1580K-15 High Voltage Probe
80K-4080K-40 High Voltage Probe
80K-680K-6 High Voltage Probe

Fiber-OpticsBuy it
FOMFOM Fiber Optic Meter

LightsBuy it
L206L206 Deluxe LED Hat Light
L210L210 Probe Light Kit
L215L215 SureGrip™ Kit with Probe Light and Probe Extender
LVD2LVD2 Volt Light

PressureBuy it
PV350PV350 Pressure Vacuum Module

Test LeadsBuy it
TL223TL223 SureGrip™ Electrical Test Lead Set
Made in the USA      

Digital Multimeter | True RMS Multimeter | HVAC Multimeter | Rugged Multimeter
Automotive Multimeter | Industrial Multimeter | Electrician’s Multimeter

Search Fluke
ResourcesProducts
Find Resources
You need Flash player 8+ and JavaScript enabled to view this video.
Learn More »

Follow us        Home  |  Site Map  |  Fluke Corporation  |  Safety Notices  |  Terms and Conditions  |  Privacy Statement  |  Disclaimer© 1995 - 2012 Fluke Corporation