The essential laboratory measurement standard
The HP 3458/HFL digital multimeter complements Fluke's line of multi-product and multifunction calibrators by combining 8½ digit standards lab measurement precision with extraordinary linearity, low internal noise, and excellent short term stability. Fluke's HP 3458/HFL has been customized for standards lab applications. Exclusive features include an ultra-high stability dc voltage reference providing one-year uncertainties as low as ±3 ppm, and a low TC resistance reference. Front panel function keys have been programmed for commonly used standards lab functions, such as math, statistics and scaling.
The linearity of the HP 3458/HFL's Multislope A to D converter has been characterized with state-of-the-art precision. Using Josephsen Junction Array intrinsic standards, linearity has been measured within ±0.05 ppm of 10V. The HP 3458/HFL's transfer accuracy for 10V dc is 0.1 ppm over 1 hour ±0.5ºC. Internal noise has been reduced to less than 0.01 ppm rms yielding 8½ digits of usable resolution
The right choice for your calibration standard dmm is the HP 3458/HFL. And it's only available from your local Fluke representative.
|
|
Performance highlights
Superb transfer measurements
- 8.5 digits resolution
- 0.1 ppm dc volts linearity
- 0.1 ppm dc volts transfer capability
- 0.01 ppm rms internal noise
|
Extraordinary uncertainty
- 0.6 ppm for 24 hours in dc volts
- 2.2 ppm for 24 hours in Ohms
- 100 ppm mid-band ac volts
- 3 ppm per year voltage reference stability
|
DC voltage stability
The long term accuracy of the HP 3458/HFL is a remarkable ±3 ppm per year - more accurate than many system dmms are after only a day.
Reduced-error resistance
The HP 3458/HFL offers superior performance in other functions as well. You can measure resistance from 10 mW to 1 GW with midrange accuracy of ±7.5 ppm.
The HP 3458/HFL offers offset-compensated Ohms on the 10Ω to 100 kΩ ranges to eliminate the errors introduced by small series voltage offsets. Usable for both two-and four-wire ohms, the HP 3458/HFL supplies a current through the unknown resistance, measures the voltage drop, sets the current to zero, and measures the voltage drop again. The result is reduced error for resistance measurements.
Precision ac voltage
The HP 3458/HFL introduces new heights of true rms ac volts performance with a choice of traditional analog or a new sampling technique for higher accuracy. For calibration sources and periodic waveforms from 1 Hz to 10 MHz, the HP 3458/HFL's precision sampling technique offers extraordinary accuracy. With ±100 ppm absolute accuracy for 45 Hz to 1 kHz or ±170 ppm absolute accuracy to 20 kHz, the HP 3458/HFL will enhance your measurement capabilities. Accuracy is maintained for up to two years with only a single 10 volt dc precision standard. No ac standards are necessary. For higher speed and less accuracy, the analog true rms ac technique has a midband absolute measurement accuracy of ±300 ppm using the same simple calibration procedure. With a bandwidth of 10 Hz to 2 MHz and reading rates to 50/second, the analog technique is an excellent choice for high throughput computer-aided testing.
Fluke-Customized Model Offers Standards Lab Convenience
To make the HP 3458/HFL even easier to use in the the standards lab, Fluke has programmed the meter's front panel so that frequently-used functions such as math, statistics, and scaling can be called with just a push of a button. A customized front panel template shows how to gain access to each function.
Easy calibration
The HP 3458/HFL gives you low cost of ownership with a simple, two-source artifact calibration. With its superior linearity, the HP 3458/HFL is fully calibrated, including ac, from a precision 10V dc source and a precision 10 kΩ resistor. All ranges and functions are automotically calibrated using precise internal ratio transfer measurements relative to these external standards. In addition, the HP 3458/HFL's internal voltage standard and resistance standard are calibrated. Now you can perform a self-verifying, self- or auto-calibration relative to the HP 3458/HFL's low drift internal standards at any time with the ACAL command. So, if your dmm's environment changes, auto-calibration optimizes your measurement accuracy.
Calibration security
Unlike other dmms, the HP 3458/HFL goes to great lengths to assure calibration security. First, a password security code "locks" calibration values and the self-calibration function. Next, you can easily store and recall a secured message for noting items, such as calibration data and due date. Plus, the HP 3458/HFL automatically increments a calibration counter each time you "unlock" the dmm - another safeguard against calibration tampering. If you have a unique situation or desire ultimate security, use the internal dmm hardwired switch to force removal of the instrument covers to perform calibration.
|
| Technical Specifications |
| Voltage DC | | | Resistance |
| Range: |
0 to 1.2 GΩ |
| Best 1 Year Specification: |
±7.5 ppm of reading |
| | Current DC |
| Range: |
0 to ±1.05A
|
| Best 1 Year Specification: |
±20 ppm of reading |
| | Voltage AC |
| Range: |
1 mV to 700V |
|
1 Hz to 10 MHz, Sine |
| Best 1 Year Specification: |
±0.007% of reading |
| | Current AC |
| Range: |
1 mV to 700V |
|
1 Hz to 10 MHz, Sine |
| Best 1 Year Specification: |
±0.007% of reading |
|
| General Math Function Specifications |
| Null |
| X-OFFSET |
|
| Minimum Execution Time = |
180 µs |
| | PERC |
| 100 x (X-PERC)/PERC |
|
| Minimum Execution Time = |
600 µs |
| | dB |
| 20 x Log (X/REF) |
|
| Minimum Execution time = |
3.9 ms |
| | RMS |
| 1-pole digital filter |
|
| Computed rms of inputs
|
|
| Minimum Execution Time = |
2.7 ms |
| | STAT |
| MEAN, SDEV computer for sample population (N-1)
|
|
| Minimum Execution Time = |
900 µs |
| | CTHRM2K (FTHRM2K) |
| ºC (ºF) temperature conversion for 2.2 kW thermistor
|
(HP 40653A)
|
| Minimum Execution Time = |
160 µs |
| | CRTD85 (FRTD85) |
| ºC (ºF) temperature conversion for RTD of 100W,
|
|
| Alpha = |
0.00385
|
| Minimum Execution Time = |
160 µs |
| | SCALE |
| (X-OFFSET)/SCALE |
|
| Minimum Execution Time = |
500 µs |
| | PFAIL |
| Based on MIN, MAX registers |
3.9 ms |
| Minimum Execution Time = |
|
| | dBm |
| 10 x Log [(X2/RES)/1 mW]
|
|
| Minimum Execution Time = |
3.9 ms |
| | FILTER |
| 1-pole digital filter
|
|
| Weighted Average of inputs
|
|
| Minimum Execution Time = |
750 µs |
| | CTHRM (FTHRM) |
| ºC (ºF) temperature conversion for 5 kW thermistor (HP40653B) |
|
| Minimum Execution Time = |
160 µs |
| | CTHRM10K (FTHRM10K) |
| ºC (ºF) temperature conversion for 10 KW thermistor
|
(HP406536) |
| Minimum Execution Time = |
160 µs |
| | CRTD92 (FRTD92) |
| ºC (ºF) temperature conversion for RTD of 100W, |
|
| Alpha = |
0.003916
|
| Minimum Execution Time = |
160 µs |
|
| Front Panel Functions |
| Null | | | Stat | | | Math Off |
|
Turns off all math functions |
| | Mean |
|
Displays the average of a number of readings within Statistics |
| | S Dev |
|
Displays the standard deviation for a range of readings within Statistics |
| | Upper/Lower |
|
Displays the highest or lowest of a range of readings within Statistics |
| | Scale |
|
Scales the reading up to 1 |
| | Synch ACV |
|
Turns on the most accurate acv mode |
| | Filter On/Off
(LF OFF) |
|
Set to Off for synch ac > 50 kHz |
|
| General Specifications |
| Operating Temperature | | | Operating Humidity Range | | | Physical Characteristics |
| Dimensions: |
88.9 mm H x 425.5 mm W x 502.9 mm D
(3.5 in. H x 16.75 in. W x 19.8 in. D) |
| Net Weight: |
12 kg (26.5 lbs)
|
| Shipping Weight: |
14.8 kg (32.5 lbs) |
| | IEEE-488 Interface |
| Complies with the following: |
IEEE-488.1 Interface Standard |
|
IEEE-728 Codes/Formats Standard |
|
HPML (HP Multimeter Language) |
| | Storage Temperature | | | Warm up Time |
|
4 hours to published specifications |
| | Power Requirements |
|
100/120V, 220/240V ±10%
|
|
48-66 Hz, 360-420 Hz automatically sensed
<30W, <80 VA (peak)
|
| Fused: |
1.5 @ 115V or 0.5A @ 230V |
| | Designed in Accordance with |
| Safety: |
IEC 348, UL1244, CSA |
| EMI: |
FTZ 1046, FCC part 15-J
|
| Classification: |
Classified under MIL-T-28800D as Type III, Class 5, Style E, and Color R |
| | Warranty | | | Input Terminals |
|
Gold-plated Tellurium Copper |
|
|
|
|
|