The most trusted tools in the world
Home  |  Products  |  Digital Multimeters  |  
This product is discontinued or reclassifiedFluke suggests:
Fluke 116 HVAC Multimeter with Temperature and Microamps

Fluke 16 General Purpose Meter for HVAC

 Fluke 16
Measures temperature and microamps

The Fluke 16 measures temperature quickly and accurately. Standard equipment includes an 80BK integrated DMM temperature probe. A microamp function is included for flame sensor measurements down to 0.1 microamps. Use the Fluke to test motor start and run capacitors up to 10,000 microfarads. Rely on the Fluke 16 to make your everyday measurements - up to 600 volts ac or dc, 40 megohms, diode test and exceptionally fast continuity.

Fluke 16 General Purpose Meter for HVAC 5 5 1 1
Very good for daily use I am an consumer electronics repair engineer and use this meter for checking anything from smd transistors, high power circuits to checking battery voltages. It's excelent as you can leave it in diode test and go messure a supply rail and it will switch to dc/ac volts automaticaly. It will put some load on it as well that way witch is good for battery testing. Even drains capacitors safely that way. The only drawback for me is having no 10 amp range for current but then I very rarely use that. September 6, 2012
1-1 of 1
  • Accurate temperature measurement from -40 to 400°C
  • Confidently test flame sensor circuits with microamp measurement down to 0.1 microamps
  • Capacitance up to 10,000 microfarads
  • 0.9% basic DC accuracy
  • 4000 count digital display
  • Min/Max recording with relative time stamp records the highest and lowest voltage readings during a 100-hour period
  • Automatic or manual ranging
  • High resistance ranges to 40 megohms
  • Millivolt range for compatibility with other accessories
  • V-Check™ mode is designed for safety
  • When measuring ohms, continuity, or diode test modes, the meter automatically switches to measuring ac or dc volts if more than 4.5V is present
  • Continuity Capture™ locates intermittent opens as brief as 250 microseconds and identifies them in a symbolic display as short-to-open or open-to-short
  • Sleep mode preserves battery life
Specifications
Voltage DC
Maximum:  600 V
Accuracy:  (0.9% + 1)
Maximum Resolution:  1 mV
Voltage AC
Maximum:  600 V
Accuracy:  (1.9% + 2)
Maximum Resolution:  1 mV
Bandwith:  50 to 400 Hz
Current DC
Maximum:  200 µA
Accuracy:  1% + 2
Maximum Resolution:  0.1 µA
Current AC
Maximum:  200 µA
Accuracy:  2% + 3
Maximum Resolution:  0.1 µA
Bandwith:  50 to 400 Hz
Resistance
Maximum:  40 MΩ
Accuracy:  0.9% + 1
Maximum Resolution:  0.1 Ω
Capacitance
Maximum:  10.000 µF
Accuracy:  1.9% + 2
Maximum Resolution:  0.001 µF
Diode
Maximum:  2.000 V
Accuracy:  (1.9% + 2)
Resolution:  1 mV
Temperature
Range:  -10 to 400 °C
Accuracy:  (1% + 0.8 °C) (typical )
Maximum Resolution:  0.1 °C
Continuity
Beeper on  <25 Ohm
Beeper off  >250 Ohm

Environmental Specifications
Operating Temperature
 -10 °C to 50 °C
Storage Temperature
 -30 °C to 60 °C indefinitely
  (to -40 °C for 100 hrs)
Humidity (Without Condensation)
 0% to 90% (-10 °C to 35 °C)
 0% to 70% (35 °C to 50 °C)
Temperature Coefficient
 (0.1 x specified accuracy)/°C (<18 °C or > 28 °C)

Safety Specifications
Overvoltage category
 EN 61010-1 to 600V CAT III

Mechanical & General Specifications
Size
 (H x W x L):3.46 cm x 7.05 cm x 14.23 cm
 (1.35 in x 2.75 in x 5.55 in)
Weight
 286 g
Warranty
 3 years
Battery Life
Alkaline:  ~ 650 hours typical
Model NameDescriptionBuy it
Fluke 16 Included accessories:
  • 80BK integrated DMM temperature probe
  • C10 Holster
  • Test Leads
  • Users manual
 

ClipsBuy it
AC220AC220 SureGrip™ Alligator Clips
AC280AC280 SureGrip™ Hook Clips
AC285AC285 SureGrip™ Alligator Clips

Test ProbesBuy it
TP220TP220 SureGrip™ Industrial Test Probes

Cases and HolstersBuy it
C100C100 Universal Carrying Case
C101C101 Hard Case
C12AC12A Meter Case
C1600C1600 Gear Box for Meter and Accessories
C550C550 Tool Bag
Fluke MeterCleaner WipesFluke MeterCleaner Wipes 

Current ClampsBuy it
i1010i1010 AC/DC Current Clamp
i200si200s AC Current Clamp
i410i410 AC/DC Current Clamp

LightsBuy it
L205L205 Mini Hat Light 
L210L210 Probe Light Kit
LVD1LVD1 Volt Light

PressureBuy it
PV350PV350 Pressure Vacuum Module

TemperatureBuy it
80AK-A80AK-A Thermocouple Adapter
80PK-2280PK-22 SureGrip™ Immersion Temperature Probe
80PK-2480PK-24 SureGrip™ Air Temperature Probe
80PK-2680PK-26 SureGrip™ Tapered Temperature Probe
80PK-2780PK-27 SureGrip™ Industrial Surface Temperature Probe
80PK-3A80PK-3A Surface Probe
80PK-880PK-8 Pipe Clamp Temperature Probe
80PK-980PK-9 General Purpose Probe
80PK-EXT80PK-EXT Extension Wire Kit

Test LeadsBuy it
TL220TL220 SureGrip™ Industrial Test Lead Set
TL221TL221 SureGrip™ Test Lead Extension Set
TL223TL223 SureGrip™ Electrical Test Lead Set
TL224TL224 SureGrip™ Insulated Test Leads
TL238TL238 SureGrip™ Test Lead Set for High Energy Environments
TL71TL71 Premium Test Lead Set
TL75TL75 Hard Point™ Test Lead Set
        
Home   |   Site Map   |   Fluke Corporation   |   Safety Notices  |   Terms and Conditions   |   Privacy Statement   |   Disclaimer © 1995 - 2013 Fluke Corporation