|
|
|
Designed by electricians. Engineered by Fluke.
The Fluke 116 digital multimeter delivers the capabilities professionals demand to troubleshoot and repair HVAC (heating, ventilation and air conditioning) systems. It has everything you need in an HVAC meter, including temperature and microamp measurements to help you quickly troubleshoot problems with HVAC equipment and flame sensors.
The Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min/Max/Average readings with elapsed time to record signal fluctuations.
Fluke 116 multimeters are independently tested for safe use in CAT III 600V environments.
And check out other members of the Fluke 110 family: the Fluke 113 Utility Multimeter, the Fluke 114 Electrical Multimeter, the Fluke 115 Multimeter and the Fluke 117 Commercial Electrician’s Multimeter.
|
Fluke 116 HVAC Multimeter with Temperature and Microamps
4.8
5
4
4
Overall, a solid product
I have owned and used this meter regularly for a little over a year now. I purchased the industrial leads and large aligator clips (pricey $) along with the magnetic hanger ( a must ) I wasn't sure of the cost to performance ratio at first, but this meter has consistantly held up to my having never dropped it ( lie ) and functioned well beyond my other Fieldpiece meter/ clampon. I however would like to see a green backlight as the white light under some circumstances makes the meter reading difficult for myself. Again, acessories are pricey, but the meter is a solid product
June 15, 2012
awesome meter
Fluke DMM's are the most consistent/trustworthy tool in my bag... i've tried the lesser DMM's in the past and will never buy anything other than Fluke. Save yourself alot of trouble and buy a fluke the first time... you won't be dissapointed!!!
June 10, 2012
Great meter
A small compact meter the does just about everything an HVAC tech needs.
June 7, 2012
Does what it's designed to do.
I've used this meter for 5 years for work, bought one for myself for side work. The magnet is great. It's perfect for HVAC, makes it easy to test for everything from 24VAC to 480 3 phase. The temp probe works great for subcooling and superheat. Have never had a problem. Wish the alligator clips were a little more beefy tho.
June 7, 2012
|
|
- Built-in thermometer for HVAC applications
- Microamps to test flame sensors
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™)
- CAT III 600 V safety rated
|
|
|
| Specifications |
| Maximum voltage between any terminal and earth ground | | | Surge protection |
|
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
| | Display |
| Digital: |
6,000 counts, updates 4 per second |
| | Bar graph |
|
33 segments, updates 32 per second |
| | Operating Temperature | | | Storage Temperature | | | Battery type |
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
| | Battery Life |
|
400 hours typical, without backlight |
|
| Accuracy Specifications |
| DC millivolts |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
| | DC volts |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.00 V / 0.1 V |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
| | Auto volts |
| Range: |
600.0 V |
| Resolution: |
0.1 V |
| Accuracy: |
2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
| | AC millivolts1 true-rms |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| | AC volts1 true-rms |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.0 V / 0.1 V |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| | Continuity |
| Range: |
600 Ω |
| Resolution: |
1 Ω |
| Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
| | Ohms |
| Range/Resolution: |
600.0 Ω / 0.1 Ω |
| Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
| Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
| Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
| Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
| Accuracy: |
0.9 % + 1 |
| Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
| Accuracy: |
1.5 % + 2 |
| | Diode Test |
| Range/Resolution: |
2.000 V / 0.001 V |
| Accuracy: |
0.9% + 2 |
| | Capacitance |
| Range/Resolution: |
1000 nF / 1 nF |
| Range/Resolution: |
10.00 μF / 0.01 μF |
| Range/Resolution: |
100.0 μF / 0.1 μF |
| Range/Resolution: |
9999 μF / 1 μF |
| Range/Resolution: |
100 μF to 1000 μF |
| Accuracy: |
1.9% + 2 |
| Range/Resolution: |
> 1000 μF |
| Accuracy: |
5% + 20% |
| | LoZ capacitance |
| Range: |
1 nF to 500 μF |
| Accuracy: |
10% + 2 typical |
| | Temperature2 (Type-K thermocouple) |
| Range/Resolution: |
-40 °C to 400 °C / 0.1 °C |
| Accuracy: |
1% + 102 |
| Range/Resolution: |
-40 °F to 752 °F / 0.2 °F |
| Accuracy: |
1% + 182 |
| | AC μamps true-rms (45 Hz to 500 Hz) |
| Range/Resolution: |
600.0 μA / 0.1 μA |
| Accuracy: |
1.0% + 2 |
| | DC μamps |
| Range/Resolution: |
600.0 μA / 0.1 μA |
| Accuracy: |
1.0% + 2 |
| | Hz (V or A input)2 |
| Range/Resolution: |
99.99 Hz / 0.01 Hz |
| Range/Resolution: |
999.99 Hz / 0.1 Hz |
| Range/Resolution: |
9.999 Hz / 0.001 Hz |
| Range/Resolution: |
50.00 Hz / 0.01 Hz |
| Accuracy: |
0.1% + 2 |
|
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
| Mechanical & General Specifications |
| Size |
|
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
| | Weight | | | Warranty | |
|
| Model Name | Description | Price List | Buy it | | Fluke 116 |
HVAC Multimeter
Model includes the following:
- 4 mm silicone test lead set
- 80BK Integrated Temperature probe
- Holster
- Installed 9 V battery
- User manual
|
|  | |
| Clips | Buy it | | AC285 | AC285 SureGrip™ Alligator Clips |  |  | | AC87 | AC87 Heavy Duty Bus Bar Clip Set |  |  |
| Cases and Holsters | Buy it | | C115 | C115 Soft Carrying Case |  |  | | C50 | C50 Meter Case |  |  | | C90 | C90 Soft Case for DMMs |  |  | | CXT170 | CXT170 Extreme Case |  |  | | Fluke MeterCleaner Wipes | Fluke MeterCleaner Wipes | |  | | TPAK | ToolPak™ |  |  |
| Lights | Buy it | | L206 | L206 Deluxe LED Hat Light |  |  | | LVD1 | LVD1 Volt Light |  |  |
| Options | Buy it | | Fluke MeterCleaner Wipes | Fluke MeterCleaner™ Wipes | |  |
| Temperature | Buy it | | 80PK-9 | 80PK-9 General Purpose Probe |  |  | | 80TK | 80TK Thermocouple Module |  |  |
| Test Leads | Buy it | | TL220 | TL220 SureGrip™ Industrial Test Lead Set |  |  | | TL223 | TL223 SureGrip™ Electrical Test Lead Set |  |  | | TL71 | TL71 Premium Test Lead Set |  |  |
|
|
|
|
|
|
|
|
|
|
|
|
|
|