Find Little Problems Before They Become Big Ones.
The industrial meter for demanding users.
New diagnostic functionality for maximizing productivity in the plant. The new 289 is the next generation high performance industrial logging multimeter designed to solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment. With the ability to log data and review it graphically on-screen, you can solve problems faster and help minimize downtime. Let the new 289 be your watchdog for systems or processes while you are off solving other problems.
Be sure to also check out the Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture designed for electronics professionals.
Maximize productivity with the combined Fluke 289 and FlukeView forms combo kit. With built-in data logger and TrendCapture capability, the 289 helps you track down elusive, intermittent problems, monitoring equipment with any of its functions while you do other jobs. Overlay your logged data from six meters or six time periods to find cause and effect relationships or for condition monitoring applications in FVF software. Turn your data into meaningful graphs and tables for a professional report. The 289/FVF combo kit gives you a practical & affordable approach to predictive maintenance.
|
Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture
4.6
5
7
7
There can be no other than Fluke in my company
I am a long time Fluke customer, and have had a long line of Fluke products that I still use every day. I am in the generator sales/service industry. I will not allow any of my employees to have less than a Fluke 187. My 189 is a back-up, but I never have to use it unless I need two at a time. Nothing silences a noisy customer better than a nice looking print-out of what his generator will, and won't, do. I enjoy it when discussing problems with a factory and they question my numbers, and I tell them that they are from a Fluke 289, they move on to another subject.
Fluke. There can be no other.
October 8, 2012
Most Useful Tool in My Bag
I'm an A/V system integrator and live audio veteran and am absolutely in love with this meter. Being able to have voltage measurements displayed in dBm and dBV is an absolutely indespensible tool in the field or at a show. The dBm range correlates perfectly to dBu when set to mimic a 600-ohm impedance. If I have a problem with a system input or output, in little more than the time it takes to connect the leads, I have all the info I need to point me in the right direction. With the AC mV function displaying dBm, I can actually directly measure microphone outputs (and make quick use of the readings), which is something I've pined for in a meter for quite a while. It's saved me countless head-scratching sessions.
The Crest Factor function is also great for quickly checking whether an audio test signal is being distorted somewhere up-stream.
I've also had it on the bench verifying performance on countless products. Trend Capture is awesome for predicting how much a setting will drift after an A/V system has been commissioned. It's nice knowing these things before a service call is ever made.
I also use the 50-Ohm range in the field to check speaker systems for proper impedance loading. It's nice having that extra bit of accuracy when you're dealing with systems that have numerous loudspeakers.
Adjustable display contrast on-the-fly makes for easy readings in any environment.
All in all, it's an absolutely wonderful tool for what I do.
I would LOVE to see a real-time graph implemented sometime in the future if it's possible. I don't like having to stop a recording and restart it to check progress.
My only real complaint is that I don't have two of them! Not to say my 87V doesn't get its fair share of attention. ;)
September 12, 2012
excellent meter
In 2004 or so Fluke came out with the 189 and I bought one. I liked the accuracy and came back in 2007/2008 and bought FOUR 289's. I use them constantly. They have paid for themselves in the recording capability which helps troubleshooting to a very high degree. Being able to capture faults in an operating system is kind of like having a storage scope but for far less cost. The accuracy is top notch and the Fluke durability is key if you need to use your meters on a daily basis for your occupation. I suggest putting lithium batteries in them, these meters are power hungry little devils, they eat up alkaline batteries like no tomorrow and the best way to combat that is to use lithium batteries. In all other regards, I recommend this meter without reservation.
July 10, 2012
This meter has the versatility for any job.
As a technician at a R&D facility I work on a variety of different projects. I not only build prototypes, but visit operational sites to troubleshoot and repair in service units. With the 289 I am able to record transients; to test not only for continuity, but to reverse continuity check; to measure frequency; to measure microamps; to test components, including the value of capacitors. Since I travel all over the world, having to carry only one meter is a real plus for me.
June 19, 2012
Good but.......
I bought this meter when it first came out, actually ordered it before it was released from my distributor. It has served well the past couple years but recently I have had to send it in for repair twice for the same problem. That doesn't sit well with me. I haven't had any problems with my other fluke products but I don't feel I can trust my 289 when it keeps getting sent back for repair.
June 16, 2012
Fits my needs, and then some
As the diagnostician in a diesel and automotive repair shop, I was in need of a meter that would allow me to perform just about any test my job would require. My choice of the 289 was obvious, as the trend-plot feature is a life saver when diagnosing intermittent issues. The large VGA screen helps readability when working over an operating engine. When working on the interior or undercarriage, the backlight is a necessity. I have also found the 50 ohm function very useful for testing the serial data wiring in modern systems as they are very sensitive to corrosion and other resistance inducing conditions. The only major issue I have with the 289's features is the lack of real time graphing and a min, max, and average display for the recording. All told, I believe I have made the right choice in purchasing this product and expect many years of use from it.
June 15, 2012
Amazing Meter
Have had the 289 for close to a year now and really like it. I had the previous version 189 since 2001 I think, this is the third fluke meter I have owned a fluke meter since 1996 and had some minor problems, of which were not a fluke problem. The first meter 87 had water damage, using it during a rain storm, the board had failed. I decided to purchase the 189 instead of getting a new board. I am in heating and air conditioning field and loved that it could read capacidence which the first version 87 did not. The 189 have had for 11 years and it was the best meter I have owned had no issues with it at all, except it fell out of my tool bag and dropped 12 feet and busted the screen. The company that I work for has a tool replacement program so I looked into the 289. I love that you can log voltage, amps and temperature 189 did that but needed a computer to review recordings. The 289 can do it at the meter which is a faster process. You will love this meter a lot. I have trusted fluke meters and amp clamps since the first day I had bought one. Will not use any other, very dependable.
June 9, 2012
|
|
Key Features Include:
- NEW – Large 50,000 count, ¼ VGA display with white backlight. Multiple sets of measurement information can simultaneously displayed at the same time.
- NEW - Logging function with TrendCapture is an essential tool for documenting the performance of your designs, processes or systems, monitoring unattended while you work on other projects. It plots measurements as a single line to help detect signal anomalies over time, storing up to 10,000 readings. Using on-board TrendCapture, you can graphically view logged readings without a PC. (Software and interface cable optional).
- NEW – Log multiple sessions or log data continuously for over 200 hours. This is useful for characterizing the performance of a design or for unattended monitoring.
- NEW - i-info button on board help screens for measurement functions. Unsure about a function? Go to that function and Press the “i button.
- NEW – LoZ Volts. Low impedance voltage function prevents false readings due to “ghost voltage. It is also the recommended mode when testing for absence or presence of live power.
- New – Low Pass Filter for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment.
- 50 ohm range – useful for measuring and comparing differences in motor winding resistance, low ohm measurements, or other contact resistance. Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current.
- NEW – Saved measurements allow you to name and recall measurements made in the field
- Real Time Clock – for automatic time stamping of saved readings
- NEW - Field upgradeable and expandable meter lets you stsay current as new capabilities are added
- NEW - Multi-lingual interface
- Min/Max/Average with Time Stamp to record signal fluctuations
- Soft keys, scroll buttons and easy navigation control access to secondary functions. Create custom displays too.
- 0.025% Basic DC accuracy
- 100 kHz ac bandwidth
- True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads.
- Measure up to 10A (20 A for 30 seconds; 10A continuous)
- 100 mF capacitance range
- Temperature function
- Relative mode to remove test lead resistance from low ohms or capacitance measurements
- Peak capture to record transients as fast as 250 μs
- Premium test leads and alligator clips included
- Optical USB PC communication interface allows for easy PC download to document logged data with FVF software (not included).
- Optional FlukeView forms enables you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents
- Optional magnetic hanger allows you to hang the meter for easy viewing while freeing your hands to focus on the job.
- Limited lifetime warranty
- CAT III 1000 V / CAT IV 600 V safety rated
|
|
|
| Specifications |
| Voltage DC |
| Accuracy |
0.025 % |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
| | Voltage AC |
| Accuracy |
0.4 %(true-rms) |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
| | Current DC |
| Accuracy |
0.06 % |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| | Current AC |
| Accuracy |
0.61 %(true-rms) |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| | Temperature (excluding probe) |
| Accuracy |
1.0 % |
| Range and Resolution |
-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) |
| | Resistance |
| Accuracy |
0.05 % |
| Range and Resolution |
500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
| | Resistance 10 50 Ω (2 wire connection) |
| Accuracy |
0.15 % + 20 |
| Range and resolution |
50.000 Ω |
| | Capacitance |
| Accuracy |
1.0 % |
| Range and Resolution |
1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF,
100.00 mF Ω |
| | Frequency |
| Accuracy |
0.005% + 5 |
| Range and Resolution |
99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
| | Additional functions/features |
| Multiple on-screen displays |
Yes |
| True-rms AC bandwidth |
100 kHz |
| DBV/dBm |
Yes |
| DC mV resolution |
1 μV |
| Megohm range |
Up to 500 M |
| Conductance |
50.00nS |
| Continuity beeper |
Yes |
| Battery/Fuse access |
Battery / Fuse |
| Peak |
250 μS |
| Elapse time clock |
Yes |
| Time of day clock |
Yes |
| Min-Max-Avg |
Yes |
| Frequency |
Yes |
| Duty Cycle |
0.01 % to 99.99 % |
| Pulse Width |
0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms |
| Hold |
Yes |
| Isolated Optical Interface |
Yes |
| Auto/Touch Hold |
Yes |
| Reading memory |
Yes |
| Log to PC |
Yes |
| Interval/Event Logging |
Yes |
| Logging Memory |
Up to 10,000 readings |
| Resistance Low Ohm |
0.001 Ω to 50.000 Ω 10 mA source |
| LoZ |
Yes |
| Low Pass Filter |
Yes |
|
| Environmental Specifications |
| Operating Temperature | | | Storage Temperature | | | Relative Humidity |
|
0% to 90% (0 °C - 37 °C) |
|
0% to 65% (37 °C - 45 °C), |
|
0 to 45 % (45 °C - 55 °C |
| | Electromagnetic Compatability | | | Vibration |
|
Random vibration per MIL-PRF-28800f Class 2 |
| | Shock |
|
1 meter drop per IEC/EN 61010-1 2nd edition |
|
| Safety Specifications |
| Overvoltage category |
|
CAT III 1000 V / CAT IV 600 V safety rated |
| | Agency Approvals | |
| Mechanical & General Specifications |
| Maximum voltage between any terminal and earth ground | | | Size |
|
(HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in) |
| | Weight | | | Battery Life |
|
100 minimum, 200 hours in logging mode |
| | Battery type |
|
6 AA alkaline batteries, NEDA 15A IEC LR6 |
|
|
| Model Name | Description | Price List | Buy it | | Fluke 289 | True-rms Industrial Logging Multimeter with TrendCapture |  | |
| CarePlans | Buy it | | G3P-Group6 |
- GOLD CarePlan.
- Models covered: 287, 289, 28II, 83-5.
- Adds "lifetime" NIST traceable factory calibration with data (Seven full calibrations).
| |  |
| Clips | Buy it | | AC220 | AC220 SureGrip™ Alligator Clips |  |  | | AC280 | AC280 SureGrip™ Hook Clips |  |  | | AC283 | AC283 SureGrip™ Pincer Clips |  |  | | AC285 | AC285 SureGrip™ Alligator Clips |  |  | | AC87 | AC87 Heavy Duty Bus Bar Clip Set |  |  | | AC89 | AC89 Heavy Duty Insulation Piercing Test Clip |  |  | | TLK225 | TLK-225 SureGrip™ Master Accessory Set |  |  |
| Test Probes | Buy it | | TL910 | TL910 Electronic Test Probes |  |  | | TP38 | TP 38 Slim Reach Test Probe Set |  |  | | TP2 | TP2 Slim Reach Test Probes |  |  | | TP220 | TP220 SureGrip™ Industrial Test Probes |  |  | | TP4 | TP4 Slim Reach Test Probes |  |  | | TP74 | TP74 Lantern Tip Test Probes | |  | | TP80 | TP80 Electronic Test Probes |  |  | | TP912 | TP912 Replacement Tips for TL910 |  |  | | TP920 | TP920 Test Probe Adapter Set |  |  |
| Accessory Kits | Buy it | | TLK-220 US | TLK-220 US SureGrip™ Industrial Test Lead |  |  |
| Batteries, Chargers and Adapters | Buy it | | IR189USB | IR189USB USB Cable adapter |  | |
| | |