The most trusted tools in the world
Home  |  Products  |  Clamp Meters  |  

Fluke 771 Milliamp Process Clamp Meter

Milliamp process clamp meters can measure mA signals without breaking the loop. The popular Fluke 771 mA Clamp Meter saves time by making fast, accurate measurements on 4-20 mA signal loops without breaking the circuit.

Contact Me
Request A Demo
Fluke 771 Milliamp Process Clamp Meter
Fluke 771 Milliamp Process Clamp Meter
Fluke 771 Milliamp Process Clamp Meter
Fluke 771 Milliamp Process Clamp Meter
Fluke 771 Milliamp Process Clamp Meter

 

Need more hours in your day?

Save time by NOT breaking the loop on 4-20 mA signal measurements.

Are you spending time:

  • Taking mA measurements by removing a wire and breaking the loop
  • Calling the control room to isolate a loop
  • Testing analog input/output on a console
  • Troubleshooting devices with mA inputs and outputs
  • Repairing intermittent or erratic 4-20 mA loops
  • Going back to the shop to get extra tools

If you need more time in your busy day take a good look at the Fluke 771 mA Clamp Meters. It’s designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.

Here are some specific ways the Fluke 771 Clamp Meters will help you:

Milliamp Clamp Features

Application

How it saves time and money

Measure mA signals for PLC and control system analog I/O without breaking the loop.

Measures low level dc current

Correlate process indication with real physical value

Measure output signals from transmitters without breaking the loop

Maintain and troubleshoot process and automation equipment without breaking the loop

No disruption to the process

Detachable clamp with extension cable

Measurements in tight locations

Enables measurements in difficult situations

Measurement Spotlight

Illuminates hard to see wires in dark enclosures

Measurement process is easier and quicker

Measure up to 99.9 mA range non-contact

Wide range of measurements

Measures 10 to 50 mA signals in older control systems

Automatic power off

After 15 minutes and 2 minute automatic off for backlight and spotlight

Saves battery life

Fluke 771 Milliamp Process Clamp Meter 3.5 5 2 2
Basic ammeter...Easily broken Basic clamp-on ammeter for low voltage applications. Barely even used and a co-worker accidently dropped it from a very short distance causing the plastic hinge piece on the clamp to break...now it is useless until I buy a new clamp. Design is definitely not rugged so handle it with care! December 4, 2012
Ease of use Great product to quick milliamp checks on control loops without disrupting the process. June 1, 2012
1-2 of 2

The 771 mA Clamp Meter features:

  • Best in class 0.2 % accuracy
  • 0.01 mA resolution and sensitivity
  • Measure 4 to 20 mA signals without ”breaking the loop”
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements


What’s the difference between the 77X models?

.

Fluke-771

Fluke-772

Fluke-773

.

Non-contact mA loop measurement

Integrated mA loop troubleshooting

Advanced process troubleshooting

mA measure, jaw
mA measure, in circuit . 
Loop power  .
mA source .
DCV measure . .
DCV source . .
mA scaled output . .
mA in / out . .

Specifications

Diameter of measurable conductor 0.177” or 4.5 mm max
Operating temperature -10 to 50 ºC
Storage Temperature -25 to 60ºC
Operating Humidity < 90% @ <30 ºC, < 75% @ 30 to 55ºC
Operating Altitude 0 to 2000 m
IP Rating IP 40
Size 59 x 38 x 212 mm, (2.32 x 1.5 x 8.35 in.)
Weight 260G, (9.1 oz.)
Vibration Random 2 g, 5 to 500 Hz
Shock 1 meter drop test (except the jaw)
EMI/RFI Meets EN61326-1
Note: For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
Temperature Coefficient 0.01% ºC
(<18? or > 28?)
Power, battery life (2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical
Warranty Three years for electronics
one year for cable and clamp assembly
mA measurement (Measured by clamp) Resolution and Range:      0 to 20.99 mA
Accuracy:                         0.2% +2 counts
Resolution and Range:      21.0 mA to 100.0 mA
Accuracy:                         1% + 5 counts
Model NameDescriptionBuy it
Fluke 771 Milliamp Process Clamp Meter

Included accessories:

  • Soft Carrying Case
  • Users Manual
 

CarePlansBuy it
G3P-Group1
  • GOLD CarePlan.
  • Models covered: 353, 355, 771, 772, and 773.
  • Extends warranty from three to five years and includes five annual NIST traceable calibrations with data.
 
S3P-Group1
  • SILVER CarePlan.
  • Models covered: 353, 355, 771, 772, and 773.
  • Extends warranty from three to five years.