High safety AC current clamp with BNC output
- Companion to your scope or power quality meter to measure up to 400 A AC.
- Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating.
- Specially designed to offer maximum utility in a compact shape.
- Take accurate current readings without breaking the circuit.
- Soft non-slippery overmold handle.
- Optional PM9081/001 BNC/Banana adapter for DMM's.
- Two ranges: 40 A & 400 A, 10 & 1 mV/Amp output.
- Max. conductor Ø 32 mm.
|
|
| Specifications |
| Nominal current range: |
| 40 A Range |
0.5 A to 40 A |
| 400 A Range |
5 A to 400 A |
| | Basic accuracy: |
| 40 A Range |
2% + 0.015 A (45-400 Hz) |
| 400 A Range |
2% + 0.04 A (45-400 Hz) |
| | Phase Shift: |
| 40 A Range |
|
| 0.5 to 1 A |
Unspecified |
| 1 A to 5 A |
4° |
| 5 A to 10 A |
3° |
| 10 A to 20 A |
3° |
| 20 A to 40 A |
2° |
| 40 A to 400 A |
NA |
| 400 A Range |
|
| 0.5 to 1 A |
NA |
| 1 A to 5 A |
NA |
| 5 A to 10 A |
Unspecified |
| 10 A to 20 A |
2° |
| 20 A to 40 A |
2° |
| 40 A to 400 A |
1.5° |
| | Typical Bandwidth: |
| 40 A Range |
5 Hz - 10 kHz |
| 400 A Range |
5 Hz - 10 kHz |
| | Output level(s): |
| 40 A Range |
10 mV/A |
| 400 A Range |
1 mV/A |
| | Crest Factor: |
| 40 A Range |
≤ 3 |
| 400 A Range |
≤ 3 to 300 A |
|
≤ 2.5 to 400 A |
|
| Safety Specifications |
| Safety |
|
CAT IV 600 V, CAT III, 1000 V |
| | Maximum Non-Destructive Current | |
| Mechanical & General Specifications |
| Warranty | | | Maximum conductor size | | | Output cable length | | | BNC Adapter | | | Dimensions | | | Weight | |
|
| Model Name | Description | Buy it | | i400s | i400s AC Current Clamp |  |  |
|
|
|
|