The most trusted tools in the world
Home  |  Products  |  Accessories  |  Current Clamps  |  

Fluke i30s AC/DC Current Clamp

 i30s

The i30s current clamp is based on Hall Effect technology for use in measurement of both DC and AC current. The i30s may be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive current measurement.

Electrical specifications
Specified current range
 30 mA to 30A dc, 30 mA to 20 A ac rms
Usable current range
 5 mA to 30 A dc, 30 mA to 20 A ac rms
Crest Factor
 1.4"
Output sensitivity
 100 mV/A
Accuracy (at +25 °C)
 ± 1 % of reading ± 2 mA
Resolution
 ± 1 mA
Load impedance
 > 100 kΩ
Conductor position sensitivity
 ± 1 % relative to center reading
Frequency range
 DC to 100 kHz (- 0.5 dB)
Phase shift below 1 kHz
 < 2 degrees
Temperature coefficient
 ± 0.01 % of reading/°C
Power supply
 9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Working voltage (see Safety Standards section)
 300 V ac rms or dc

General specifications
Maximum conductor size
 19 mm diameter
Output connection
 Safety BNC connector, supplied with safety 4 mm adapter
Output zero
 Manual adjust via thumbwheel
Cable length
 2 meters
Operating temperature range
 0 °C to +50 °C
Storage temperature range (with battery removed)
 -20 °C to +85 °C
Operating humidity
 15 % to 85 % (non-condensing)
Weight
 250 g
Safety standards
 BS EN 61010-1: 2001
 BS EN 61010-2-032: 2002
 BS EN 61010-031: 2002
 300 Vrms, Category III, Pollution Degree 2
 Use of the probe on uninsulated conductors is limited to 300 V acrms or dc and frequencies below 1 kHz.
EMC Standards
 EN 61326: 1998 +A1, A2, & A3
Model NameDescriptionBuy it
i30sFluke i30s AC/DC Current Clamp
        