The most trusted tools in the world
Home  |  Products  |  Accessories  |  Clamp Meter Accessories  |  

i2500-18 iFlex™ Flexible Current Probes

Unprecedented measurement flexibility

The iFlex flexible current probe (included) expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access.
i2500-18
i2500-18
i2500-18
i2500-18
i2500-18
Be ready for anything.

The Fluke iFlex flexible current probes expand the measurement range of the select Fluke meters to 2500 A ac while providing the ultimate measurement flexibility. The iFlex probes connect directly to the meter, displaying current measurements without error prone scaling factors. The 1.8 m (6 ft) cord allows separation between the measurement location and the clamp meter making it easier to view the display. The large loop size and thin cross section allow measurement of awkward sized conductors and improved wire access in crowded spaces. Available in 25 cm (10 in) and 45 cm (18 in) sizes.

Safety Conformance
IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV

Features and benefits

  • Expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access
  • CAT IV 600 V, CAT III 1000 V
  • 7.5 mm coil diameter allows measurement in tight spaces
  • Ergonomic design allows easy operation with one hand
  • 1.8 m (6 ft) cable
  • Three-year warranty

How-to open the i2500-18 and i2500-10 iFlex flexible current probes:
Twist to unlock Pull to open

Safety Conformance
IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV

Specifications

i2500-18 and i2500-10

Range

Resolution

Accuracy

AC Current*

2500 A

0.1 A

3% ± 5 digits**

Frequency*

500 Hz

0.1 Hz

0.5% ± 5 digits

External magnetic
field rejection

(with cable >10 cm from the coupling)

40 dB

Inrush*

 •

Safety rating

CAT III 1000 V, CAT IV 600 V

*When used with compatible Fluke meter. Accuracy stated includes probe and meter accuracy.
** For position accuracy at non-optimum positions, see Position sensitivity specifications table “A

Position sensitivity specifications

Distance from optimum

i2500-10

i2500-18

Additional iFlex error

A

0.5 in (12.7 mm)

1.4 in (35.6 mm)

± 0.5%

B

0.8 in (20.3 mm)

2.0 in (50.8 mm)

± 1.0%

C

1.4 in (35.6 mm)

2.5 in (63.5 mm)

± 2.0%


Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature.
Model NameDescriptionBuy it
i2500-18i2500-18 iFlex™ Flexible Current Probes  
        
Related Products

3 reviews
 
 Fluke 374 True-rms AC/DC Clamp Meter »

3 reviews
 
 Fluke 375 True-rms AC/DC Clamp Meter »

8 reviews
 
 Fluke 376 True-rms AC/DC Clamp Meter with iFlex™  »

Clamp Meter Videos

Fluke 381 with Remote Display (.swf) »
iFlex™ Flexible Current Probe (.swf) »
iFlex™ and Tight Spaces (.swf) »
iFlex™ and Large Conductors (.swf) »
iFlex™ and High Current (.swf) »
Home   |   Site Map   |   Fluke Corporation   |   Safety Notices  |   Terms and Conditions   |   Privacy Statement   |   Disclaimer © 1995 - 2013 Fluke Corporation