Reliable, highly accurate measurements for the test and development of power electronics
The compact Fluke Norma Series Power Analyzers provide the latest measurement technology to assist engineers with the development and testing of motors, inverters, lighting, power supplies, transformers and automotive components.
Based on a patented, high-bandwidth architecture, the instruments deliver high-precision measurements of single or three-phase current and voltage, harmonics analysis, Fast Fourier Transformation (FFT) analysis, as well as calculations of power and other derived values.
The Series consists of the Fluke Norma 4000 Three-Phase Power Analyzer and the Fluke Norma 5000 Six-Phase Power Analyzer. These rugged, high-precision analyzers provide unmatched price performance for easy and reliable use in the field, or as a bench unit in laboratories and on test benches.
Applications
- Electric motors and inverter drive systems – Through detailed spectrum analysis and dynamic torque calculation capabilities, switching losses caused by the inverter are accurately measured, and a thorough evaluation is made of torque transients and harmonics at higher frequencies.
- Inverter drive system – Simultaneous measurement of all electrical and mechanical power parameters in the same time window enables users to observe the influence one component has on another, or on the whole system.
- Lighting systems – A wide bandwidth of up to 10 MHz and a high sampling rate up to 1 MHz provide detailed signal analysis at ballast outputs. A unique shunt technique enables power measurements at very high frequencies. Simultaneous measurement of input and output power provides instant calculation of ballast losses.
- Transformers – Synchronous six-phase power measurements enable highly accurate efficiency and loss calculations of large power transformers even at very low power factors. Synchronous multiphase resistance measurements of transformer coils are also possible.
- Automotive – Synchronous electrical input and mechanical output measurements provide complete data on the efficiency and losses of individual components as well as the whole drive system.
|
|
Fluke Norma 4000: Ideal for field testing, the Fluke Norma 4000 Three-Phase Power Analyzer offers easy and straight-forward operation with unmatched price performance. Features include: 1 to 3 power phases, 5.7” / 144 mm color display, harmonic analysis, scope mode, vector diagram display, recorder function, Fluke NormaView PC software and expandable 4 MB RAM data memory.
Fluke Norma 5000: Providing the highest bandwidth on the market, the Fluke Norma 5000 Six-Phase Power Analyzer is the ideal test and analysis tool for the development of frequency converters and lighting equipment. Features include: 3 to 6 power phases, optional internal printer, and all of the Fluke Norma 4000 features and functionality described above.
- Compact design makes it easy to carry and saves working space.
- Simple user interface ensures easy, intuitive operation.
- A variety of standard configurations allows users to choose the exact functionality required for their unique application.
- Simultaneous parallel acquisition of all phases allows accurate viewing of dynamic events on all phases at exactly the same point in time.
- All inputs are galvanically isolated to avoid short circuits in all applications.
- Voltage, current and power harmonics measured up to the 40th harmonic for complete analysis.
- FFT analysis, vector diagram, and Digital Oscilloscope (DSO) mode included in the base unit for complete analysis capability.
- User-selectable average time – from 15ms up to 3600s – for dynamic measurements.
- 4 MB on-board memory (expandable to 128 MB) for storage of measured values.
- Fast and easy connection to a PC – RS232 and USB included as standard; optional IEEE488, Ethernet, or USB2.0.
- PI1 process interface to measure torque and speed with external sensors, plus four analog outputs for easy use on motor and drive applications.
- 341kHz or 1 MHz sample rates for detailed signal analysis.
- Bandwidth from dc to 3 MHz / 10 MHz for reliable measurement precision.
- Fluke NormaView PC software for data download, analysis & report writing.
|
|
|
| General Specifications |
| Number of Phases |
| Fluke Norma 4000: |
1 to 3 |
| Fluke Norma 5000: |
3, 4 or 6 |
|
| Weight |
| Fluke Norma 4000: |
Approx. 5 kg (11 lb.) |
| Fluke Norma 5000: |
Approx. 7 kg (15 lb.) |
|
| Size |
| Fluke Norma 4000: |
150 mm x 237 mm x 315 mm
(5.9 in x 9.3 in x 12.4 in) |
| Fluke Norma 5000: |
150 mm x 447 mm x 315 mm
(5.9 in x 17.6 in x 12.4 in) |
|
| On-board Printer |
| Fluke Norma 4000: |
No |
| Fluke Norma 5000: |
Yes (optional) |
|
| Display |
|
Color, 5.7“ / 144 mm - 320 x 240 pixel |
|
User-selectable background lighting and contrast. |
|
| Bandwidth |
|
dc to 3MHz or dc to 10MHz depending on input module |
|
| Basic Accuracy |
|
0.2%, 0.1% or 0.03% depending on input modules |
|
| Sampling Rate |
|
0.33 MHz or 1 MHz depending on input modules |
|
| Voltage Input Range |
|
| Current Input Range (direct, not via shunt) |
|
0.03 mA to 20 A depending on input module |
|
| Memory for Configurations |
|
| Memory for Settings |
|
| Fast Fourier Transformation (FFT) |
|
| RS232/USB Interface |
|
| PI1 Process interface (8 analog/impulse inputs and 4 analog outputs) |
|
| IEEE 488.2/GPIB interface (1 MBit/s Ethernet / 10 MBit/s or 100 MBit/s) |
|
| Fluke NormaView PC software (for data download, analysis & report writing) |
|
| Basic Functions |
| Fast Fourier Transformation (FFT) |
|
Calculation of harmonics with graphical representation. Up to 3 bar graphs are displayed at the same time. |
|
Measured values: U, I, P per phase |
|
Order: 1st to 40th harmonics, maximum half sample frequency |
|
| Digital Oscilloscope (DSO) |
|
Simultaneous display of up to 3 measured values on sample level. Quick view of curve form and distortion. |
|
| Integration function (energy) |
|
Simultaneous display of up to 6 configurable numeric values. Start/Stop conditions and positive negative direction available. |
|
| Vector Display |
|
Vector display of HO1 up to 6 signals. For easy testing of the right connection of the instrument and quick overview of the phase angle of each signal. |
|
| Recorder |
|
Display of average values over time for trend determination. |
|
| RAM data memory |
|
Storing of sample and average values; setting of start and stop conditions. |
|
From the RAM approximately 4 MB are available for the storage of measured values. |
|
| Configuration |
|
Set up the analyzer to measure and display data in the format required. |
|
| Ambient Conditions |
| Working Temperature Range |
|
5 °C to 35 °C (41 °F to 95 °F) |
|
| Storage Temperature Range |
|
-20 °C to 50 °C (-4 °F to 122 °F) |
|
| Housing Material |
|
Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements. |
|
| Climatic Class |
|
KYG DIN 40040, max. 85 % relative humidity, non-condensing. |
|
| Power supply |
|
85 V ac to 264 V ac, 50 Hz to 60 Hz, dc 100 to 260 V, ca. 40 VA European plug with switch. Binding post for current available on some models. |
|
| Measuring Inputs |
|
Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket. |
|
| Operation |
|
Membrane keyboard with cursor – function keys and direct functions. |
|
| Connections |
|
Rear panel of the 3-phase Analyzer |
|
| Measured Values |
| |
|
Non-gapping calculation of averaged values for each phase. In three phase system additionally calculation of total power and averaging of V and I of the three phases. The fundamental H01 will be calculated in synchronous mode also for these values. |
|
Urms effective value, Urm rectified mean, Um mean value |
|
Up-, Up+, Upp peak values |
|
Ucf crest factor Ucf, Uff form factor |
|
Ufc fundamental content |
|
Uthd distortion factor DIN, IEC |
|
Irms effective value, Irm rectified mean, Im mean value |
|
Ip-, Ip+, Ipp peak values |
|
Icf crest factor Icf, Iff form factor |
|
Ifc fundamental content |
|
Ithd distortion factor DIN, IEC |
|
P active power [W] |
|
Q reactive power [Var] |
|
S apparent power [VA] |
|
ë, cos. phase angular |
|
Integral function for active power P, reactive power Q, apparent power S, voltage (Um) and current (Im), |
|
Number of digits 4 or 5 dependent on measured value. |
|
| Frequency and Synchronization |
| Range |
|
DC and 0.2 Hz to sample rate |
|
| Accuracy |
|
±0.01 % of measured value (reading) |
|
| |
| • |
Channels which can be selected: all U/I or external input. |
| • |
One of three low pass filter with different frequencies can be switched into the signal. |
| • |
The frequency is always visible on the top of the screen. |
| • |
The BNC synchronization socket on backside of the instrument can be used either as input or output. |
| • |
The input signals can be measured up to the sample rate of the power phase. The maximum level must not be higher then 50V. |
| • |
The output signal is a pulsed 5Volts TTL signal (frequency depends on the measured synch frequency). |
|
| Configuration Memory |
| |
|
Up to 15 user configurations can be saved into a permanent memory and reloaded later on. Changes that were not saved are lost after switching off the instrument. |
|
| Interface |
| |
|
RS232 interface for upload of firmware and data exchange with the PC. A printer can be connected over an external converter. |
|
| Options |
|
IEEE 488.2 / 1 MBit/s |
|
Ethernet / 10 MBit/s or 100 Mbit/s |
|
| Standards and Safety |
| Electrical Safety |
|
EN 61010-1 / 2nd Edition 1000 V CAT II (600V CAT III) |
|
Degree of pollution 2, safety Class I |
|
EN 61558 for transformer |
|
EN 61010-2-031/032 for accessories |
|
| Maximum inputs |
|
For voltage inputs Measurement range 1000 Veff, 2 kVpeak |
|
For current inputs Measurement range 10 Aeff, 20 Apeak |
|
| Test voltage |
| Net input |
case (protective conductor): 1.5 KV AC |
| Net connection |
Measurement input: 5.4 kV AC |
| Measurement inputs |
Case: 3.3 kV AC |
| Measurement input |
input: 5.4 kV |
|
| Electromagnetic susceptibility |
| Emission: |
IEC 61326-1, EN 50081-1, EN 55011 Class B |
| Immunity: |
IEC 61326-1 / Annex A (industrial sector), EN 50082-1 |
|
Power Phases
The Fluke Norma 4000 Power Analyzer can be equipped with up to three power phases and the Fluke Norma 5000 Power Analyzer can be equipped with up to six power phases. Users can select the power phase best suited for their application. Specifications vary depending on the model of the power phase.
Each modular plug-in power phase consists of a voltage and a current measurement channel. Each measuring channel is available for each basic unit, however only one kind of channel can be used per unit. Check standard configurations.
Power Phase Overview
| Power Phase Channels |
| PP42 |
| Accuracy: |
0.2% (0.1% rd + 0.1 % rg) |
| Current range: |
20 A |
| Sampling rate: |
341 kHz |
| Bandwidth: |
3 MHz |
|
| PP50 |
| Accuracy: |
0.1% (0.05% rd + 0.05 % rg) |
| Current range: |
10 A |
| Sampling rate: |
1 MHz |
| Bandwidth: |
10 MHz |
|
| PP54 |
| Accuracy: |
0.1% (0.05% rd + 0.05 % rg) |
| Current range: |
10 A |
| Sampling rate: |
341 kHz |
| Bandwidth: |
3 MHz |
|
| PP64 |
| Accuracy: |
0.03% (0.02% rg + 0.01% rg) |
| Current range: |
10 A |
| Sampling rate: |
341 kHz |
| Bandwidth: |
3 MHz |
|
|
| Model Name | Description | Price List | Buy it | | Fluke Norma 4000 |
High Precision Power Analyzer
Includes:
- Power supply cable
- 5.7“ / 144 mm color display
- RS232/USB interface for data download
- Space for three power-phases and options
- Fluke NormaView PC software
- User’s manual
- Test certificate
- Calibration values
|
|  | | | Fluke Norma 5000 |
High Precision Power Analyzer
Includes:
- Power supply cable
- 5.7“ / 144 mm color display
- Internal printer
- RS232/USB interface for data download
- Space for six power-phases and options
- Fluke NormaView PC software
- User’s manual
- Test certificate
- Calibration values
|
|  | |
|
Standard Configurations
| Short Description | Description |
| Fluke-N4K 1PP42 |
|
Fluke-Norma 4000, single phase with PP42 power phase input module |
| | Fluke-N4K 3PP42 |
|
Fluke-Norma 4000, three phase with 3xPP42 power phase input modules |
| | Fluke-N4K 3PP42I |
|
Fluke-Norma 4000, three phase with 3xPP42 power phase input modules with IEEE488 / Ethernet interface |
| | Fluke-N4K 3PP42IP |
|
Fluke-Norma 4000, three phase with 3xPP42 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels |
| | Fluke-N4K 3PP42B |
|
Fluke-Norma 4000, three phase with 3xPP42 power phase input modules with current binding post |
| | Fluke-N4K 3PP42IB |
|
Fluke-Norma 4000, three phase with 3xPP42 power phase input modules with current binding post with IEEE488 / Ethernet interface |
| | Fluke-N4K 3PP42IPB |
|
Fluke-Norma 4000, three phase with 3xPP42 power phase input modules with current binding post with IEEE488 / Ethernet interface and analog / digital output channels |
| | Fluke-N4K 3PP50 |
|
Fluke-Norma 4000, three phase with 3xPP50 power phase input modules |
| | Fluke-N4K 3PP50I |
|
Fluke-Norma 4000, three phase with 3xPP50 power phase input modules with IEEE488 / Ethernet interface |
| | Fluke-N4K 3PP50IP |
|
Fluke-Norma 4000, three phase with 3xPP50 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels |
| | Fluke-N4K 3PP52IB |
|
Fluke-Norma 4000, three phase with 3xPP52 power phase input modules with current binding post with IEEE488 / Ethernet interface |
| | Fluke-N4K 3PP54I |
|
Fluke-Norma 4000, three phase with 3xPP54 power phase input modules with IEEE488 / Ethernet interface |
| | Fluke-N4K 3PP54IP |
|
Fluke-Norma 4000, three phase with 3xPP54 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels |
| | Fluke-N5K 3PP50 |
|
Fluke-Norma 5000, three phase with 3xPP50 power phase input modules |
| | Fluke-N5K 3PP50I |
|
Fluke-Norma 5000, three phase with 3xPP50 power phase input modules with IEEE488 / Ethernet interface |
| | Fluke-N5K 3PP50IP |
|
Fluke-Norma 5000, three phase with 3xPP50 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels |
| | Fluke-N5K 3PP54 |
|
Fluke-Norma 5000, three phase with 3xPP54 power phase input modules |
| | Fluke-N5K 3PP54I |
|
Fluke-Norma 5000, three phase with 3xPP54 power phase input modules with IEEE488 / Ethernet interface |
| | Fluke-N5K 3PP54R |
|
Fluke-Norma 5000, three phase with 3xPP54 power phase input modules and printer |
| | Fluke-N5K 3PP54IP |
|
Fluke-Norma 5000, three phase with 3xPP54 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels |
| | Fluke-N5K 3PP54IR |
|
Fluke-Norma 5000, three phase with 3xPP54 power phase input modules with IEEE488 / Ethernet interface and printer |
| | Fluke-N5K 3PP64 |
|
Fluke-Norma 5000, three phase with 3xPP64 power phase input modules |
| | Fluke-N5K 3PP64I |
|
Fluke-Norma 5000, three phase with 3xPP64 power phase input modules with IEEE488 / Ethernet interface |
| | Fluke-N5K 3PP64IP |
|
Fluke-Norma 5000, three phase with 3xPP64 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels |
| | Fluke-N5K 3PP64R |
|
Fluke-Norma 5000, three phase with 3xPP64 power phase input modules and printer |
| | Fluke-N5K 3PP64IR |
|
Fluke-Norma 5000, three phase with 3xPP64 power phase input modules with IEEE488 / Ethernet interface and printer |
| | Fluke-N5K 3PP64IPR |
|
Fluke-Norma 5000, three phase with 3xPP64 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels and printer |
| | Fluke-N5K 4PP54 |
|
Fluke-Norma 5000, three phase with 4xPP54 power phase input modules |
| | Fluke-N5K 4PP54IP |
|
Fluke-Norma 5000, three phase with 4xPP54 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels |
| | Fluke-N5K 6PP42IB |
|
Fluke-Norma 5000, three phase with 6xPP42 power phase input modules with current binding post with IEEE488 / Ethernet interface |
| | Fluke-N5K 6PP42IBR |
|
Fluke-Norma 5000, three phase with 6xPP42 power phase input modules with current binding post with IEEE488 / Ethernet interface and printer |
| | Fluke-N5K 6PP50IP |
|
Fluke-Norma 5000, three phase with 6xPP50 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels |
| | Fluke-N5K 6PP50IR |
|
Fluke-Norma 5000, three phase with 6xPP50 power phase input modules with IEEE488 / Ethernet interface and printer |
| | Fluke-N5K 6PP50IPR |
|
Fluke-Norma 5000, three phase with 6xPP50 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels and printer |
| | Fluke-N5K 6PP50I |
|
Fluke-Norma 5000, three phase with 6xPP50 power phase input modules with IEEE488 / Ethernet interface |
| | Fluke-N5K 6PP54I |
|
Fluke-Norma 5000, three phase with 6xPP54 power phase input modules with IEEE488 / Ethernet interface |
| | Fluke-N5K 6PP54IP |
|
Fluke-Norma 5000, three phase with 6xPP54 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels |
| | Fluke-N5K 6PP54IR |
|
Fluke-Norma 5000, three phase with 6xPP54 power phase input modules with IEEE488 / Ethernet interface and printer |
| | Fluke-N5K 6PP54IPR |
|
Fluke-Norma 5000, three phase with 6xPP54 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels and printer |
| | Fluke-N5K 6PP64I |
|
Fluke-Norma 5000, three phase with 6xPP64 power phase input modules with IEEE488 / Ethernet interface |
| | Fluke-N5K 6PP64IP |
|
Fluke-Norma 5000, three phase with 6xPP64 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels |
| | Fluke-N5K 6PP64IR |
|
Fluke-Norma 5000, three phase with 6xPP64 power phase input modules with IEEE488 / Ethernet interface and printer |
| | Fluke-N5K 6PP64IPR |
|
Fluke-Norma 5000, three phase with 6xPP64 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels and printer |
|
|
| CarePlans | Buy it | | G2P-Group5 |
- GOLD CarePlan.
- Models covered: N4K Series (FLUKE-N4K 1PP42, FLUKE-N4K 3PP42, FLUKE-N4K 3PP50, FLUKE-N4K 3PP54I, FLUKE-N4K 3PP54IP), N5K Series (FLUKE-N5K 3PP50IP, FLUKE-N5K 3PP64).
- Extends warranty from two to four years and includes four annual NIST traceable calibrations with data.
| |  | | S2P-Group5 |
- SILVER CarePlan.
- Models covered: N4K Series (FLUKE-N4K 1PP42, FLUKE-N4K 3PP42, FLUKE-N4K 3PP50, FLUKE-N4K 3PP54I, FLUKE-N4K 3PP54IP), N5K Series (FLUKE-N5K 3PP50IP, FLUKE-N5K 3PP64).
- Extends warranty from two to four years.
| |  |
| Batteries, Chargers and Adapters | Buy it | | WYE Adaptor | Fluke Norma WYE Adaptor (external accessory box) | | |
| Cables and Hardware | Buy it | | Measurement Cable Set | Measurement Cable Set (for one power phase) | | |
| Options | Buy it | | 10 A Traxial Shunt | 10 A Traxial Shunt | | | | 100 A Shunt | 100 A Shunt with Cables (0.001 Ω, 0 to 0.5 MHz) | | | | 150 A Shunt | 150 A Shunt with Cables (0.5 mΩ, 0 to 0.5 MHz) | | | | 30 A Traxial Shunt | 30 A Traxial Shunt | | | | 300 A Shunt | 300 A Shunt with Cables (0.1 mΩ, 0 to 1 MHz) | | | | 32 A Planar Shunt | 32 A Planar Shunt | | | | 500 A Shunt | 500 A Shunt with Cables (0.1 mΩ, 0 to 0.2 MHz) | | | | Cables for 32 A Planar Shunt | Cables for 32 A Planar Shunt | | | | LG Shunt Cables | LG Shunt Cables for High Current Shunts | | |
|
|
|
|
|
|
|
|
|