Keeping your world up and running.
Home  |  Products  |  Clamp Meters  |  

Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex®

The Fluke 376 FC Wireless True-rms AC/DC Clamp Meter offers logging capabilities, includes the iFlex™ Flexible Current Probe, and measures up to 1000 V and 1000 A, ac or dc.
Fluke 376 FC transmits data wirelessly to your smartphone
Fluke 376 FC transmits data wirelessly to your smartphone
Fluke 376 FC with included iFlex® Current Probe
Fluke 376 FC transmits data wirelessly to your smartphone
Fluke 376 FC with inclusions

The Fluke 376 FC is part of the Fluke Connect family of wireless test tools.  Now you can:

  • Log and trend measurements to pinpoint intermittent faults
  • Transmit results wirelessly via Fluke Connect® Measurements app
  • Create and send reports right from the field
  • Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices

The Fluke 376 FC is the direct replacement for the Fluke 376 Clamp Meter.

  • Connect your meter to your smartphone with Fluke Connect Measurements
  • Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
  • Record results directly to your phone and the Cloud
  • Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
  • Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
  • iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
  • TPAK magnetic hanging strap (included)
  • Integrated VFD low pass filter for accurate motor drive measurements
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • CAT IV 600 V, CAT III 1000 V safety rating
  • Three-year warranty
  • Soft carrying case

Measurement Capability

  • 1000 A ac and dc current measurement
  • 2500 A ac current measurement with iFlex flexible current probe
  • 1000 V ac and dc voltage measurement
  • True-rms voltage and current for accurate measurements on non-linear signals
  • Frequency measurement to 500 Hz with body jaw and iFlex
  • Resistance measurement to 60 kΩ with continuity detection
  • Min, max, average, and inrush recording to capture variations automatically
  • 500 mV dc measurement range to interface with other accessories
  • 1000 μF capacitance measurement

General Specifications
AC Current via Jaw
Range 999.9 A
Resolution  0.1 A
Accuracy  2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz) 3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Flexible current probe
  i2500-10 Flex i2500-18 Flex
A    
Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm)
Error ±0.5 % ±0.5 %
B    
Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm)
Error ±1.0 % ±1.0 %
C    
Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm)
Error ±2.0 % ±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 1000 A
Resolution 0.1 A
Accuracy 2% ±5 digits
AC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1.5% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ±5 digits
Frequency via Jaw
Range 5.0 Hz to 500.0 Hz
Resolution  0.1 Hz
Accuracy  0.5% ±5 digits
Trigger level  5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 5.0 Hz to 500.0 Hz
Resolution  0.1 Hz
Accuracy  0.5% ±5 digits
Trigger level  5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy 1% ±5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground 1000 V
Batteries 2 AA, NEDA 15A, IEC LR6
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity -
non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude 3000 m
Storage altitude 12,000 m
Size (L x W x H) 249 x 85 x 45 mm
Weight 395 g
Jaw opening 34 mm
Flexible current probe diameter 7.5 mm
Flexible current probe cable length
(head to electronics connector)
1.8 m
Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
IP rating IEC 60529: IP30, non-operating
Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Model NameDescriptionPrice List
Fluke 376 FC

Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex®
Includes:

  • 18-inch iFlex® Flexible Current Probe
  • TPAK magnetic hanging strap
  • Soft carrying case
  • TL75 test leads
  • Two AA Alkaline batteries
  • Coated instruction card
  • Safety information sheet
Price List

ClipsPrice List
AC220AC220 SureGrip™ Alligator Clip SetPrice List
AC87AC87 Heavy Duty Bus Bar Clip SetPrice List
AC89AC89 Heavy Duty Insulation Piercing Test ClipPrice List

Test ProbesPrice List
TP1TP1 Slim Reach Test Probe (flat blade)Price List

Cases and HolstersPrice List
C550C550 Tool BagPrice List

LightsPrice List
L206L206 Deluxe LED Hat LightPrice List
LVD1LVD1 Volt LightPrice List

Test LeadsPrice List
TL75TL75 Hard Point™ Test Lead SetPrice List

Fluke Connect® SmartView® desktop software is available in all countries but Fluke Connect system is not. Check with your local Fluke distributor.

All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4s and up running iOS 8 or higher, iPad (in an iPhone frame on iPad) and Galaxy S4, Nexus 5, HTC One running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.

Home   |   Site Map   |   Fluke Corporation   |   Safety Notices
Privacy Statement   |   Terms of Use  |   Terms and Conditions of Sale   |   Terms and Conditions of Service
© 1995 - 2018 Fluke Corporation