The Fluke FC Wireless t3000 Temperature Kit provides measurement of many common electrical parameters, and lets you correlate these with temperature readings

The Fluke 3000 FC Series Wireless Multimeter with the Fluke ConnectÂŪ app has all the essentials for convenient test and measurement troubleshooting:

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

With the Fluke t3000 FC Wireless K-Type Temperature Module you can:

  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings

āļ āļēāļžāļĢāļ§āļĄāļœāļĨāļīāļ•āļ āļąāļ“āļ‘āđŒ: Fluke t3000 FC Wireless Temperature Kit

The Fluke FC Wireless t3000 Temperature Kit is part of the Fluke Connect team of wireless test tools

Connect the t3000 FC Wireless Temperature Module to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.

You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke ConnectÂŪ modules as a system for multiple measurements.

From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the Fluke Connect remote modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.

Now you can take readings on moving machinery, with only the measurement module in harm’s way.

āļ‚āđ‰āļ­āļĄāļđāļĨāļˆāļģāđ€āļžāļēāļ°: Fluke t3000 FC Wireless Temperature Kit

Fluke 3000 FC Wireless Digital Multimeter

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ¹([% of Reading] + [Number of least significant digits]).

AC Voltage
Range 1ResolutionAccuracy 2 3 4Accuracy 2 3 4
45 Hz to 500 Hz500 Hz to 1 kHz
600.0 mV0.1 mV1.0% + 32.0% + 3
6.000 V0.001 V
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of â‰Ī 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add Âą(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
FunctionRangeResolutionAccuracy
mV600.0 mV0.1 mV0.09% + 2
V6.000 V0.001 V0.09% + 2
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V0.15% + 2
ÎĐ600 ÎĐ1 ÎĐMeter beeps at < 25 ÎĐ, beeper detects opens or shorts of 250 Ξs or longer.
ÎĐ600.0 ÎĐ0.1 ÎĐ0.5% + 2
6.000 kÎĐ0.001 kÎĐ0.5% + 1
60.00 kÎĐ0.01 kÎĐ
60.00 kÎĐ0.1 kÎĐ
600.0 kÎĐ0.001 MÎĐ
50.00 MÎĐ0.01 MÎĐ1.5% + 3
Diode test2.000 V0.001 V1% + 2
ÂĩF1000 nF1 nF1.2% + 2
10.00 ΞF0.01 ΞF
100.0 ΞF0.1 ΞF
9999 ΞF11 ΞF10% typical
1. In the 9999 ΞF range for measurements to 1000 ΞF, the measurement accuracy is 1.2% + 2.
AC and DC Current
FunctionRange 1ResolutionAccuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA0.01 mA1.5% + 3
400.0 mA 30.1 mA
mA DC 260.00 mA0.01 mA0.5% + 3
400.0 mA 30.1 mA
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
RangeResolutionAccuracy 1
99.99 Hz0.01 Hz0.1% + 1
999.9 Hz0.1 Hz
9.999 kHz0.001 kHz
99.99 kHz0.01 kHz
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
FunctionOverload
protection
Input impedance
(nominal)
Common mode rejection ratio
(1 kÎĐ unbalance)
Normal mode rejection
1100 Vrms> 10 MÎĐ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 Vrms> 10 MÎĐ < 100 pF> 60 dB, DC to 60 Hz 
1100 Vrms> 10 MÎĐ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scale voltageTypical short circuit current
To 6 MÎĐ50 MÎĐ
1100 V RMS< 2.7 VDC< 0.7 VDC< 0.9 VDC< 350 mA
1100 Vrms< 2.7 VDC2.000 VDC< 1.1 mA
mA Function
Overload ProtectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functionsThe specified accuracy of the measurement function Âą 12 counts for changes > 350 mS in duration.
AC functionsThe specified accuracy of the measurement function Âą 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 VDC or AC rms
ÎĐ fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate4/sec
Volts, amps, ohms6000 counts
Frequency10,000 counts
Capacitance1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall, or steel electrical enclosureUp to 3.5 m
TemperatureOperating-10°C to 50°C
Storage-40°C to 60°C
Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
AltitudeOperating2,000 m
Storage12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety complianceANSI/ISA 61010-1 / (82.02.01)3rd edition
CAN/CSA-C22.2 No 61010-1-123rd edition
UL 61010-13rd edition
IEC/EN 61010-12010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution degree2
Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools
 

Fluke t3000 FC Wireless K-Type Temperature Module

General Specifications
Range K-Type-200°C to 1372°C
Resolution0.1°C
Accuracy¹[0.5% + 0.5°C] counts
Input terminalsK-type mini
LCD w/backlight3 Â― digits
Log rate/interval1 sec minimum/adjustable by PC
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall or steel electrical enclosureUp to 3.5 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficient0.01% of reading +0.03°C per °C
Temperature scaleITS-90
Operating humidity90% at 35°C, 75% at 40°C, 45% at 50°C
AltitudeOperating2,000 m
Storage12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, CAT I, 3rd edition Pollution Degree 2
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Size (H x W x D)16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

āļĢāļļāđˆāļ™: Fluke t3000 FC Wireless Temperature Kit

FLK-T3000 FC Kit
Fluke t3000 FC Wireless Temperature Kit
80PK-1 K-Type Bead Thermocouple
āļ‹āļ·āđ‰āļ­āđ€āļĨāļĒ

Includes:

  • Fluke 3000 FC Series Wireless Multimeter
  • Fluke t3000 K-Type Thermocouple Thermometer
  • TL175 Test Leads
  • AC175 Alligator Clips
  • Other K-Type temperature probes also available