The most trusted tools in the world
Home  |  Products  |  Wireless Testers  |  Multimeter Kits  |  

Fluke CNX 3000 HVAC System

A complete wireless measurement system that lets you make primary measurements on your multimeter while simultaneously viewing measurements from the remote current and temperature modules.
Fluke CNX 3000 HVAC System
Fluke CNX 3000 HVAC System
Fluke CNX v3000 AC Wireless Voltage Module
Fluke CNX i3000 iFlex AC Wireless Current Module
Fluke CNX 3000 Wireless Multimeter
The CNX 3000 HVAC System is part of the Fluke team of wireless troubleshooting tools.

Connect the CNX a3000 AC Wireless Current Clamp Module to your test point, and view the results up to 20 meters away on the CNX Wireless Multimeter. Plus, you can connect the CNX t3000 K-type wireless temperature module and view remote temperature measurements. You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems. Or use as a stand-alone measurement tool or combine with other CNX modules as a system for multiple measurements. From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the CNX remote modules captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. CNX wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm’s way.

View other members of the wireless team »

The CNX 3000 HVAC System provides measurement of all common electrical and temperature parameters.


The CNX 3000 Wireless Multimeter offers:
  • True-RMS AC and DC voltage measurements to 1000V
  • True-RMS AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX Recording
  • CAT III 1000 V; CAT IV 600 V; IP54

The CNX t3000 K-Type Wireless Temperature Module offers:
  • Temperature measurements from -200 °C to 1372 °C
  • ± 0.5% accuracy
  • Memory recording up to 65,000 readings
  • Backlit LCD display; IP42 with thermocouple attached

The CNX a3000 AC Wireless Current Clamp Module provides:
  • True-RMA AC current measurements to 400 A
  • 2% accuracy to 100Hz, 2-1/2% accuracy to 500Hz
  • Memory recording up to 65,000 readings
  • iFlex current probe allows you to get into tight, awkward spaces
  • Backlit LCD display
  • CAT III 600 V; IP42
Connect to the test point and read the result up to 20 meters away.

The CNX wireless system can track up to 10 measurement modules simultaneously, with results sent to a PC for detailed analysis.

CNX 3000 Wireless Multimeter

For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC voltage
Range ¹ Resolution Accuracy ² ³
45 Hz to 500 Hz 500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function Range Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09 % + 2
V 6.000 V 0.001 V 0.09 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15 % + 2
600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
600.0 Ω 0.1 Ω 0.5 % + 2
6.000 kΩ 0.001 kΩ 0.5 % + 1
60.00 kΩ 0.01 kΩ
60.00 kΩ 0.1 kΩ
600.0 kΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 3
Diode test 2.000 V 0.001 V 1 % + 2
µF 1000 nF 1 nF 1.2 % + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF¹ 1 μF 10 % typical
¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

AC and DC Current
Function Range¹ Resolution Accuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA 0.01 mA 1.5 % + 3
400.0 mA ³ 0.1 mA
mA DC ² 60.00 mA 0.01 mA 0.5 % + 3
400.0 mA 0.1 mA
¹ All AC current ranges are specified from 5 % of range to 100 % of range.
² Input burden voltage (typical): 400 mA input 2 mV/mA.
³ 400.0 mA accuracy specified up to 600 mA overload.

Frequency
Range Resolution Accuracy ¹
99.99 Hz 0.01 Hz 0.1 % + 1
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

Input Characteristics
Function Overload
Protection
Input Impedance
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz  
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale Typical short circuit current
To 6 MΩ 50 MΩ
1100 V RMS < 2.7 V DC < 0.7 V DC < 0.9 V DC < 350 mA
1100 V RMS < 2.7 V DC 2.000 V DC < 1.1 mA

Function Overload Protection Overload
mA Fused, 44/100 A, 1000 V FAST Fuse 600 mA overload for 2 minutes maximum, 10 minutes rest minimum

MIN/MAX Recording
Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.

General Specifications
Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 300 hours minimum
Temperature Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Relative humidity 0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency 2.4 GHz ISM Band 20 meter range
Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)
Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL:UL 61010-1: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006.
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP54

Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.


Fluke CNX t3000 K-Type Wireless Temperature Module


Specifications

Range

K-Type: -200 °C to 1372 °C

Resolution

0.1 °C

Accuracy

± [0.5 % + 0.3 °C] counts

Input terminals

K-Type mini

LCD w/backlight

3 digits 

Log rate/interval

1 sec minimum/adjustable by PC

Battery type

2 AA, NEDA 15 A, IEC LR6

Battery life

400 hours

Memory

Record up to 65,000 readings

RF communications

2.4 GHZ ISM Band

RF communication range

20 Meters

Operating temperature

-10 °C to +50 °C

Storage temperature

-40 °C to +60 °C

Operating humidity

90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C

EMC

EN 61326-1:2006

Safety compliance

CAT 1 per IEC/EN 61010-1:2010
EN/IEC 61010-2-030:2010

Pollution degree

2

Temperature coefficient

0.01 % of reading +0.03 °C per °C

Certifications

CSA, FCC T68-FWCS IC:6627A-FWCS

Ingress Protection (IP) rating

IP42 with thermocouple attached

Size (HxWxD)

16.5 cm x 6.35 cm x 3.56 cm
(6.5 in x 2.5 in x 1.4 in)

Weight

.22 kg (8 oz)

Fluke CNX a3000 AC Wireless Current Clamp Module


Specifications

Range

400.0 A

Resolution

0.1 A

Accuracy

400.0 A:2 % ± 5 digits (10 Hz to 100 Hz)
2.5 % ± 5 digits (100 Hz to 500 Hz)

Inrush

Max displayed reading: 999.9A

Crest factor (50 Hz/60 Hz)

3.0 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2 %

Display

3-1/2 digits,  LCD w/backlight

Log rate/interval

1 sec minimum/adjustable by PC

Battery type

2 AA, NEDA 15 A, IEC LR6

Battery life

400 hours

Memory

Record up to 65,000 readings

RF communications

2.4 GHZ ISM Band

RF communication range

20 Meters

Operating temperature

-10 °C to +50 °C

Storage temperature

-40 °C to +60 °C

Operating humidity

90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C

EMC

EN 61326-1:2006

Safety compliance

EN/IEC 61010-1-30:2010 to 600 V Measurement Category (CAT) III
EN/IEC 61010-2-030:2010
EN/IEC 61010-2-032:2002

Pollution degree

2

Temperature coefficient

Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)

Safety rating

CAT III 600 V

Certifications

CSA, FCC T68-FWCS IC:6627A-FWCS

Ingress Protection (IP) rating

IP42

Size (HxWxD)

20.3 cm x 7.49 cm x 3.56 cm
(8 in x 2.95 in x 1.4 in)

Weight

.22 kg (8 oz)

Jaw opening

34 mm (1.33 in)

Model NameDescription
CNX 3000 HVACFluke CNX 3000 HVAC System
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX a3000 AC Wireless Current Clamp Module
  • Fluke CNX t3000 K-Type Wireless Temperature Module
  • Fluke CNX pc3000 Wireless PC Adapter and Software
  • TL175 Test Leads
  • AC175 Alligator Clips
  • 80PK-1 K-Type Bead Thermocouple
  • Magnetic Hanging Strap
  • Soft Carrying Case
  • CNX 3000 GMFluke CNX 3000 General Maintenance System
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX v3000 AC Wireless Voltage Module
  • Fluke CNX i3000 iFlex AC Wireless Current Module
  • iFlex i2500-10 Flexible Current Probe
  • Fluke CNX pc3000 Wireless PC Adapter and Software
  • TL224 Test Leads
  • TL175 Test Leads
  • AC175 Alligator Clips
  • AC285 Alligator Clips
  • Two (2) Magnetic Hanging Straps
  • Soft Carrying Case
  • CNX 3000 INDFluke CNX 3000 Industrial System
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX v3000 AC Wireless Voltage Module
  • Three (3) Fluke CNX i3000 iFlex AC Wireless Current Modules
  • Three (3) iFlex i2500-10 Flexible Current Probes
  • Fluke CNX pc3000 Wireless PC Adapter and Software
  • TL224 Test Leads
  • TL175 Test Leads
  • AC175 Alligator Clips
  • AC285 Alligator Clips
  • Four (4) Magnetic Hanging Straps
  • CNX 3000Fluke CNX 3000 Wireless Multimeter
  • True-RMS Wireless Multimeter
  • TL175 Test Leads
  • AC175 Alligator Clips
  • CNX v3000Fluke CNX v3000 AC Wireless Voltage Module
  • True-RMS AC Voltage Module
  • TL224 Test Leads
  • AC285 Alligator Clips
  • Magnetic Hanging Strap
  • CNX i3000Fluke CNX i3000 iFlex AC Wireless Current Module
  • True-RMS Flexible Current Meter
  • iFlex i2500-10 Flexible Current Probe
  • TL175 Test Leads
  • AC175 Alligator Clips
  • Magnetic Hanging Strap
  • CNX a3000Fluke CNX a3000 AC Wireless Current Clamp Module
  • True-RMS AC Clamp Meter
  • CNX t3000Fluke CNX t3000 K-Type Wireless Temperature Module
  • K-Type Thermocouple Thermometer
  • 80PK-1 K-Type Bead Thermocouple
  • Magnetic Hanging Strap
  • CNX i3000 KitFluke CNX i3000 iFlex AC Current Measurement Kit
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX i3000 iFlex AC Wireless Current Module
  • iFlex i2500-10 Flexible Current Probe
  • TL175 Test Leads
  • AC175 Alligator Clips
  • Magnetic Hanging Strap
  • Soft Carrying Case
  • CNX v3000 Kit

    Fluke CNX v3000 AC Voltage Kit

  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX v3000 AC Wireless Voltage Module
  • TL224 Test Leads
  • TL175 Test Leads
  • AC175 Alligator Clips
  • AC285 Alligator Clips
  • Magnetic Hanging Strap
  • Soft Carrying Case
  • CNX a3000 KitFluke CNX a3000 AC Current Clamp Kit
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX a3000 AC Wireless Current Clamp Module
  • TL175 Test Leads
  • AC175 Alligator Clips
  • Soft Carrying Case
  • CNX t3000 KitFluke CNX t3000 Temperature Measurement Kit
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX t3000 K-Type Wireless Temperature Module
  • TL175 Test Leads
  • AC175 Alligator Clips
  • 80PK-1 K-Type Bead Thermocouple
  • Magnetic Hanging Strap
  • Soft Carrying Case

  • Cases and Holsters
    CNX C3001CNX small modular Case C3001
    Compatible with wireless modules Fluke CNX
    CNX C3002CNX C3002 Modular DMM 2-Compartment Soft Case
  • Compatible with Fluke CNX Wireless Multimeter
  • Inner pocket and carrying handle
  • CNX C3003CNX C3003 Modular 3-Compartment Soft Case
  • Compatible with Fluke CNX wireless modules and meters
  • Three adjustable compartments, inner pocket, and carrying handle

  • PC Adapter and Software
    CNX pc3000Fluke CNX pc3000 PC Adapter
    CNX PC Adapter Software

    Temperature
    80PK-180PK-1 Bead Probe (Type K)

    Test Leads
    TL175TL175 TwistGuard™ Test Leads
    Related Products
     
     Fluke CNX 3000 Industrial System »
     
     Fluke CNX i3000 iFlex AC Wireless Current Module »
    Home   |   Site Map   |   Fluke Corporation   |   Safety Notices  |   Terms and Conditions   |   Privacy Statement   |   Disclaimer© 1995 - 2013 Fluke Corporation