The CNX v3000 Wireless Voltage Module is part of the Fluke team of wireless troubleshooting tools.
Connect the CNX v3000 AC Wireless Voltage Module to your test point, and view the results up to 20 meters away on the CNX 3000 Wireless Multimeter. You’ll save time, with less run-around collecting multiple measurements. Plus, no more writing down data as the CNX 3000 captures up to 65,000 sets of time stamped min/max/avg readings. CNX wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm’s way.
View other members of the wireless team »
|
The CNX v3000 AC Wireless Voltage Module provides:
- True-RMS AC voltage measurements to 1000V
- ±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz
- Memory recording up to 65,000 readings
- Backlit LCD display
- CAT IV 600 V, CAT III 1000 V; IP42
The CNX wireless system can track up to 10 measurement modules simultaneously, with results sent to a PC for detailed analysis.
|
 |
|
|
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
| AC Voltage |
| Range ¹ |
Resolution |
Accuracy ² ³ |
| 45 Hz to 500 Hz |
500 Hz to 1 kHz |
| 6.000 V |
0.001 V |
1.0 % + 3 |
2.0 % + 3 |
| 60.00 V |
0.01 V |
| 600.0 V |
0.1 V |
| 1000 V |
1 V |
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
² Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. |
| General Specifications |
|
LCD w/backlight
|
3½ digits, 6000 counts, updates 4/sec
|
|
Battery type
|
2 AA, NEDA 15 A, IEC LR6
|
|
Battery life
|
400 Hours
|
|
Memory
|
Record up to 65,000 readings
|
|
Unbound listen interval
|
5 seconds
|
|
RF communications
|
2.4 GHZ ISM Band
|
|
RF communication range
|
20 Meters
|
|
Operating temperature
|
-10 °C to +50 °C
|
|
Storage temperature
|
-40 °C to +60 °C
|
|
Operating humidity
|
90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C
|
|
EMC
|
EN 61326-1:2006
|
|
Safety compliance
|
EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
EN/IEC 61010-031:2002+A1:2008
|
|
Pollution degree
|
2
|
|
Temperature coefficient
|
0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
|
|
Safety rating
|
CAT IV 600 V, CAT III 1000 V
|
|
Certifications
|
CSA, FCC T68-FWCS IC:6627A-FWCS
|
|
Ingress Protection (IP) rating
|
IP42
|
|
Size (HxWxD)
|
16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
|
|
Weight
|
.22 kg (8 oz)
|
|
| Model Name | Description | Price List | | CNX v3000 | Fluke CNX v3000 AC Wireless Voltage Module
True-RMS AC Voltage Module
TL224 Test Leads
AC285 Alligator Clips
Magnetic Hanging Strap
| | CNX 3000 | Fluke CNX 3000 Wireless Multimeter
True-RMS Wireless Multimeter
TL175 Test Leads
AC175 Alligator Clips
| | CNX i3000 | Fluke CNX i3000 iFlex AC Wireless Current Module
True-RMS Flexible Current Meter
iFlex i2500-10 Flexible Current Probe
TL175 Test Leads
AC175 Alligator Clips
Magnetic Hanging Strap
| | CNX a3000 | Fluke CNX a3000 AC Wireless Current Clamp Module
True-RMS AC Clamp Meter
| | CNX t3000 | Fluke CNX t3000 K-Type Wireless Temperature Module
K-Type Thermocouple Thermometer
80PK-1 K-Type Bead Thermocouple
Magnetic Hanging Strap
| | CNX v3000 Kit |
Fluke CNX v3000 AC Voltage Kit
Fluke CNX 3000 Wireless Multimeter
Fluke CNX v3000 AC Wireless Voltage Module
TL224 Test Leads
TL175 Test Leads
AC175 Alligator Clips
AC285 Alligator Clips
Magnetic Hanging Strap
Soft Carrying Case
| | CNX a3000 Kit | Fluke CNX a3000 AC Current Clamp Kit
Fluke CNX 3000 Wireless Multimeter
Fluke CNX a3000 AC Wireless Current Clamp Module
TL175 Test Leads
AC175 Alligator Clips
Soft Carrying Case
| | CNX i3000 Kit | Fluke CNX i3000 iFlex AC Current Measurement Kit
Fluke CNX 3000 Wireless Multimeter
Fluke CNX i3000 iFlex AC Wireless Current Module
iFlex i2500-10 Flexible Current Probe
TL175 Test Leads
AC175 Alligator Clips
Magnetic Hanging Strap
Soft Carrying Case
| | CNX t3000 Kit | Fluke CNX t3000 Temperature Measurement Kit
Fluke CNX 3000 Wireless Multimeter
Fluke CNX t3000 K-Type Wireless Temperature Module
TL175 Test Leads
AC175 Alligator Clips
80PK-1 K-Type Bead Thermocouple
Magnetic Hanging Strap
Soft Carrying Case
| | CNX 3000 GM | Fluke CNX 3000 General Maintenance System
Fluke CNX 3000 Wireless Multimeter
Fluke CNX v3000 AC Wireless Voltage Module
Fluke CNX i3000 iFlex AC Wireless Current Module
iFlex i2500-10 Flexible Current Probe
Fluke CNX pc3000 Wireless PC Adapter and Software
TL224 Test Leads
TL175 Test Leads
AC175 Alligator Clips
AC285 Alligator Clips
Two (2) Magnetic Hanging Straps
Soft Carrying Case
| | CNX 3000 IND | Fluke CNX 3000 Industrial System
Fluke CNX 3000 Wireless Multimeter
Fluke CNX v3000 AC Wireless Voltage Module
Three (3) Fluke CNX i3000 iFlex AC Wireless Current Modules
Three (3) iFlex i2500-10 Flexible Current Probes
Fluke CNX pc3000 Wireless PC Adapter and Software
TL224 Test Leads
TL175 Test Leads
AC175 Alligator Clips
AC285 Alligator Clips
Four (4) Magnetic Hanging Straps
| | CNX 3000 HVAC | Fluke CNX 3000 HVAC System
Fluke CNX 3000 Wireless Multimeter
Fluke CNX a3000 AC Wireless Current Clamp Module
Fluke CNX t3000 K-Type Wireless Temperature Module
Fluke CNX pc3000 Wireless PC Adapter and Software
TL175 Test Leads
AC175 Alligator Clips
80PK-1 K-Type Bead Thermocouple
Magnetic Hanging Strap
Soft Carrying Case
|
| Clips | | AC285 | AC285 SureGrip™ Alligator Clip Set |
| Cases and Holsters | | CNX C3001 | CNX small modular Case C3001
Compatible with wireless modules Fluke CNX | | CNX C3002 | CNX C3002 Modular DMM 2-Compartment Soft Case
Compatible with Fluke CNX Wireless Multimeter
Inner pocket and carrying handle | | CNX C3003 | CNX C3003 Modular 3-Compartment Soft Case
Compatible with Fluke CNX wireless modules and meters
Three adjustable compartments, inner pocket, and carrying handle |
| PC Adapter and Software | | CNX pc3000 | Fluke CNX pc3000 PC Adapter CNX PC Adapter Software |
| Test Leads | | TL224 | TL224 SureGrip™ Silicone Test Lead Set |
|
|
|
|
|
|
|
|
|