The most trusted tools in the world
Home  |  Products  |  Digital Multimeters  |  

Fluke 116 HVAC Multimeter with Temperature and Microamps

  • Measures temperature, microamps and more
  • LoZ function prevents false readings due to ghost voltage
  • Built-in thermometer for HVAC applications
  • Engineered by Fluke, with a three-year warranty
 Fluke 116

Designed by electricians. Engineered by Fluke.

Compact true-rms meter for HVAC (heating ventilation air conditioning) troubleshooting. The Fluke 116 was specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors.

Also check out the Fluke 114 Electrical Multimeter, the Fluke 115 Multimeter, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.

Fluke 116

  • Built-in thermometer for HVAC applications
  • Microamps to test flame sensors
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™)
  • CAT III 600 V safety rated

Specifications
Maximum voltage between any terminal and earth ground
 600 V
Surge protection
 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
 33 segments, updates 32 per second
Operating Temperature
 -10 °C to + 50 °C
Storage Temperature
 -40 °C to + 60 °C
Battery type
 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
 400 hours typical, without backlight

Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:  600.0 V
Resolution:  0.1 V
Accuracy:  2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  1.5 % + 2
Diode Test
Range/Resolution:  2.000 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 μF / 0.01 μF
Range/Resolution:  100.0 μF / 0.1 μF
Range/Resolution:  9999 μF / 1 μF
Range/Resolution:  100 μF to 1000 μF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 μF
Accuracy:  5% + 20%
LoZ capacitance
Range:  1 nF to 500 μF
Accuracy:  10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution:  -40 °C to 400 °C / 0.1 °C
Accuracy:  1% + 102
Range/Resolution:  -40 °F to 752 °F / 0.2 °F
Accuracy:  1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution:  600.0 μA / 0.1 μA
Accuracy:  1.0% + 2
DC μamps
Range/Resolution:  600.0 μA / 0.1 μA
Accuracy:  1.0% + 2
Hz (V or A input)2
Range/Resolution:  99.99 Hz / 0.01 Hz
Range/Resolution:  999.99 Hz / 0.1 Hz
Range/Resolution:  9.999 Hz / 0.001 Hz
Range/Resolution:  50.00 Hz / 0.01 Hz
Accuracy:  0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

Mechanical & General Specifications
Size
 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight
 550 g
Warranty
 3 years
Model NameDescription
Fluke 116 HVAC Multimeter Model includes the following:
  • 4 mm silicone test lead set
  • 80BK Integrated Temperature probe
  • Holster
  • Installed 9 V battery
  • User manual

Clips
AC285AC285 SureGrip™ Alligator Clip Set
AC87AC87 Heavy Duty Bus Bar Clip Set

Cases and Holsters
C115C115 Soft Carrying Case
C50C50 Soft Meter Case
C90C90 Soft Meter Case
CXT170CXT170 Extreme Case
TPAKTPAK ToolPak, Meter Hanging Kit

Lights
L206L206 Deluxe LED Hat Light
LVD1LVD1 Volt Light

Options
Fluke MeterCleaner WipesMC6 Fluke MeterCleaner™ Wipes

Temperature
80PK-980PK-9 General Purpose Probe (Type K)
80TK80TK Thermocouple Module (Type K)

Test Leads
TL220TL220 SureGrip™ Industrial Test Lead Kit
TL223TL223 SureGrip™ Electrical Test Lead Kit
TL71TL71 Test Lead Set
Related Products
 
 TL175 TwistGuard™ Test Leads »
 
 TPAK ToolPak, Meter Hanging Kit »
Home   |   Site Map   |   Fluke Corporation   |   Safety Notices  |   Terms and Conditions   |   Privacy Statement   |   Disclaimer© 1995 - 2013 Fluke Corporation