This kit is a direct replacement for the obsolete 16/322 HVAC combo kit.

For the complete solution to HVAC troubleshooting the extra value-packed HVAC Multimeter and Clamp Meter Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.
|
|
Fluke116 Digital Multimeter. Designed by Electricians. Engineered by Fluke.
- Fluke 116 HVAC Multimeter with Temperature and Microamps.
- TL175 Hard Point Test Lead Set.
- TPak ToolPak Magnetic Meter Hanging Strap.
- Flexible Cuff Pipe Clamp Thermocouple.
- 80BK Integrated Temperature Probe.
- 80AK-A Thermocouple Adapter.
- C115 Deluxe Soft Carrying Case with Shoulder Strap.
Fluke 323 True-rms Clamp Meter. Rugged. Reliable. Precise.
- 400 A ac current measurement.
- 600 V ac and dc voltage measurement.
- True-rms ac voltage and current for accurate measurements on non-linear signals.
- Resistance measurement up to 40 kΩ with continuity detection.
- Slim, ergonomic design.
- CAT IV 300V/CAT III 600 V safety rating.
|
Fluke 116 HVAC Multimeter with Temperature and Microamps
| Specifications |
| Maximum voltage between any terminal and earth ground |
600 V |
| Surge protection |
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
| Display |
6,000 counts, updates 4 per second |
| Bar graph |
33 segments, updates 32 per second |
| Operating Temperature |
-10 °C to + 50 °C |
| Storage Temperature |
-40 °C to + 60 °C |
| Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
| Battery Life |
400 hours typical, without backlight |
| Accuracy Specifications |
| DC millivolts |
Range |
600.0 mV |
| Resolution |
0.1 mV |
| Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
| DC volts |
Range/Resolution |
6.000 V / 0.001 V |
| Range/Resolution |
60.00 V / 0.01 V |
| Range/Resolution |
600.00 V / 0.1 V |
| Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
| Auto volts |
Range |
600.0 V |
| Resolution |
0.1 V |
| Accuracy |
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
| AC millivolts1 true-rms |
Range |
600.0 mV |
| Resolution |
0.1 mV |
| Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
| AC volts1 true-rms |
Range/Resolution |
6.000 V / 0.001 V |
| Range/Resolution |
60.00 V / 0.01 V |
| Range/Resolution |
600.0 V / 0.1 V |
| Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
| Continuity |
Range |
600 Ω |
| Resolution |
1 Ω |
| Accuracy |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
| Ohms |
Range/Resolution |
600.0 Ω / 0.1 Ω |
| Range/Resolution |
6.000 kΩ / 0.001 kΩ |
| Range/Resolution |
60.00 kΩ / 0.01 kΩ |
| Range/Resolution |
600.0 kΩ / 0.1 kΩ |
| Range/Resolution |
6.000 MΩ / 0.001 MΩ |
| Accuracy |
0.9 % + 1 |
| Range/Resolution |
40.00 MΩ / 0.01 MΩ |
| Accuracy |
1.5 % + 2 |
| Diode Test |
Range/Resolution |
2.000 V / 0.001 V |
| Accuracy |
0.9% + 2 |
| Capacitance |
Range/Resolution |
1000 nF / 1 nF |
| Range/Resolution |
10.00 μF / 0.01 μF |
| Range/Resolution |
100.0 μF / 0.1 μF |
| Range/Resolution |
9999 μF / 1 μF |
| Range/Resolution |
100 μF to 1000 μF |
| Accuracy |
1.9% + 2 |
| Range/Resolution |
> 1000 μF |
| Accuracy |
5% + 20% |
| LoZ capacitance |
Range |
1 nF to 500 μF |
| Accuracy |
10% + 2 typical |
| Temperature2 (Type-K thermocouple) |
Range/Resolution |
-40 °C to 400 °C / 0.1 °C |
| Accuracy |
1% + 102 |
| Range/Resolution |
-40 °F to 752 °F / 0.2 °F |
| Accuracy |
1% + 182 |
| AC μamps true-rms (45 Hz to 500 Hz) |
Range/Resolution |
600.0 μA / 0.1 μA |
| Accuracy |
1.0% + 2 |
| DC μamps |
Range/Resolution |
600.0 μA / 0.1 μA |
| Accuracy |
1.0% + 2 |
| Hz (V or A input)2 |
Range/Resolution |
99.99 Hz / 0.01 Hz |
| Range/Resolution |
999.99 Hz / 0.1 Hz |
| Range/Resolution |
9.999 Hz / 0.001 Hz |
| Range/Resolution |
50.00 Hz / 0.01 Hz |
| Accuracy |
0.1% + 2 |
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
| Mechanical & General Specifications |
| Size |
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
| Weight |
550 g |
| Warranty |
3 years |
Fluke 323 True-rms Clamp Meter
| Specifications |
| AC current |
Range 400.0 A |
|
| Accuracy |
2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz) |
| AC voltage |
Range |
600.0 V |
| Accuracy |
1.5 % ± 5 digits |
| DC voltage |
Range |
600.0 V |
| Accuracy |
1.0 % ± 5 digits |
| Resistance |
Range |
400.0 Ω/ 4000 Ω |
| Accuracy |
1.0 % ± 5 digits |
| Continuity |
≤ 70 Ω |
| AC response |
True-rms |
| Data hold |
Yes |
| Size |
H x W x D (mm) |
207 x 75 x 34 |
| Max wire diameter |
30 mm (600 MCM) |
| Weight |
265 g |
| Category rating |
CAT III 600 V
CAT IV 300 V |
| Warranty |
Two-year |
|
| Model Name | Description | Price List | | Fluke 116/323 Kit | Includes:
Fluke 116 HVAC Multimeter with Temperature and Microamps
Fluke 323 True-rms Clamp Meter |
| Test Leads | | TL225 | TL225 SureGrip™ Stray Voltage Adapter Test Lead Kit |
|
|
|
|