The most trusted tools in the world
Home  |  Products  |  Digital Multimeters  |  

Fluke 114 Electrical Multimeter

  • Compact multimeter for electrical troubleshooting
  • Easy one-hand operation with automatic AC/DC selection
  • Engineered by Fluke, with a three-year warranty
 Fluke 114

Designed by electricians. Engineered by Fluke.

Compact true-rms meter for electrical troubleshooting. The Fluke 114 is the troubleshooting tool for “go/no-go” testing. It includes a feature to prevent false readings caused by ghost voltage.

Also check out the Fluke 115 Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.

Fluke 114

  • AutoVolt: automatic ac/dc voltage selection
  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated

Safety conformance

All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.

Specifications
Maximum voltage between any terminal and earth ground
 600 V
Surge protection
 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
 33 segments, updates 32 per second
Operating Temperature
 -10 °C to + 50 °C
Storage Temperature
 -40 °C to + 60 °C
Battery type
 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
 400 hours typical, without backlight

Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:  600.0 V
Resolution:  0.1 V
Accuracy:  2.0 % + 3 (dc, 45 Hz to 500 Hz)4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  5 % + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

Mechanical & General Specifications
Size
 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight
 550 g
Warranty
 3 years
Model NameDescription
Fluke 114 Electrical Multimeter

Model includes the following:
  • Holster
  • Installed 9 V battery
  • Test leads
  • User manual


Clips
AC285AC285 SureGrip™ Alligator Clip Set
AC87AC87 Heavy Duty Bus Bar Clip Set

Cases and Holsters
C50C50 Soft Meter Case
C90C90 Soft Meter Case
CXT170CXT170 Extreme Case
TPAKTPAK ToolPak, Meter Hanging Kit

Current clamps
i400si400s AC Current Clamp

Lights
L206L206 Deluxe LED Hat Light
LVD1LVD1 Volt Light

Options
Fluke MeterCleaner WipesMC6 Fluke MeterCleaner™ Wipes

Temperature
80PK-980PK-9 General Purpose Probe (Type K)
80TK80TK Thermocouple Module (Type K)

Test Leads
TL220TL220 SureGrip™ Industrial Test Lead Kit
TL223TL223 SureGrip™ Electrical Test Lead Kit
TL71TL71 Test Lead Set
Related Products
 
 TL175 TwistGuard™ Test Leads »
 
 TPAK ToolPak, Meter Hanging Kit »
Home   |   Site Map   |   Fluke Corporation   |   Safety Notices  |   Terms and Conditions   |   Privacy Statement   |   Disclaimer© 1995 - 2013 Fluke Corporation