Designed by electricians. Engineered by Fluke.
Compact true-rms meter for electrical troubleshooting. The Fluke 114 is the troubleshooting tool for “go/no-go” testing. It includes a feature to prevent false readings caused by ghost voltage.
Also check out the Fluke 115 Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.
|
|
- AutoVolt: automatic ac/dc voltage selection
- Large white LED backlight to work in poorly lit areas
- Resistance and continuity
- Min/Max/Average to record signal fluctuations
- CAT III 600 V safety rated
|
Safety conformance
All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.
|
|
| Specifications |
| Maximum voltage between any terminal and earth ground | | | Surge protection |
|
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
| | Display |
| Digital: |
6,000 counts, updates 4 per second |
| | Bar graph |
|
33 segments, updates 32 per second |
| | Operating Temperature | | | Storage Temperature | | | Battery type |
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
| | Battery Life |
|
400 hours typical, without backlight |
|
| Accuracy Specifications |
| DC millivolts |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
| | DC volts |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.00 V / 0.1 V |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
| | Auto volts |
| Range: |
600.0 V |
| Resolution: |
0.1 V |
| Accuracy: |
2.0 % + 3 (dc, 45 Hz to 500 Hz)4.0 % + 3 (500 Hz to 1 kHz) |
| | AC millivolts1 true-rms |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
| | AC volts1 true-rms |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.0 V / 0.1 V |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
| | Continuity |
| Range: |
600 Ω |
| Resolution: |
1 Ω |
| Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. |
| | Ohms |
| Range/Resolution: |
600.0 Ω / 0.1 Ω |
| Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
| Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
| Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
| Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
| Accuracy: |
0.9 % + 1 |
| Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
| Accuracy: |
5 % + 2 |
|
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
| Mechanical & General Specifications |
| Size |
|
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
| | Weight | | | Warranty | |
|
| Model Name | Description | Price List | | Fluke 114 |
Electrical Multimeter
Model includes the following:
- Holster
- Installed 9 V battery
- Test leads
- User manual
|
|
| Clips | | AC285 | AC285 SureGrip™ Alligator Clip Set | | AC87 | AC87 Heavy Duty Bus Bar Clip Set |
| Cases and Holsters | | C50 | C50 Soft Meter Case | | C90 | C90 Soft Meter Case | | CXT170 | CXT170 Extreme Case | | TPAK | TPAK ToolPak, Meter Hanging Kit |
| Current clamps | | i400s | i400s AC Current Clamp |
| Lights | | L206 | L206 Deluxe LED Hat Light | | LVD1 | LVD1 Volt Light |
| Options | | Fluke MeterCleaner Wipes | MC6 Fluke MeterCleaner™ Wipes |
| Temperature | | 80PK-9 | 80PK-9 General Purpose Probe (Type K) | | 80TK | 80TK Thermocouple Module (Type K) |
| Test Leads | | TL220 | TL220 SureGrip™ Industrial Test Lead Kit | | TL223 | TL223 SureGrip™ Electrical Test Lead Kit | | TL71 | TL71 Test Lead Set |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|