Heating, ventilation, air conditioning
(HVAC) technicians require a service tool that can consistently keep up
with their demands. The Fluke 902 expands the existing line of quality
Fluke clamp meters by delivering the features necessary to diagnose and
repair HVAC systems. Combined with True RMS technology and a CAT III 600
V rating, the Fluke 902 helps technicians do their jobs safely and
accurately.
|
|
The new Fluke 902 True RMS HVAC Clamp Meter provides the accuracy, reliability and ruggedness that define Fluke test tools. It is designed for HVAC technicians for the systems they service and install daily. With True RMS technology and a CAT III 600V rating, HVAC technicians can troubleshoot and maintain HVAC equipment safely and with confidence in the results.
Use the Fluke 902 to get more done:
- Capture flue gas temperatures
- Conduct flame rod testing
- Measure start and run motor capacitors
- Measure supply side current and voltage as well as load side current and voltage
- Measure current and voltage phase balance on 3 phase systems
- Troubleshoot compressor electrical motor faults
- Measure performance of variable frequency drives
|
Features:
- Designed for HVAC applications with capacitance, DC Current (µA), and temperature measurements
- Small body and jaws fit perfectly in your hand and into tight places
- Handy 'Display Hold' button keeps measurements on the display
- Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch)
- Large, backlit display is easy-to-see in less than ideal conditions
- Auto shut-off maximizes battery life so the meter works when you need it
- Three year warranty
|
|
|
| Specifications |
| Voltage DC |
| Range |
0 – 600.0 V |
| Accuracy |
1% ± 5 counts |
| | Voltage AC (True RMS) |
| Range |
0 – 600.0 V |
| Accuracy |
1% ± 5 counts (50/60 Hz) |
| | Current AC (True RMS) |
| Range |
0 – 600.0 A |
| Accuracy |
2.0% ± 5 counts (50/60 Hz) |
| | Current DC |
| Range |
0 - 200.0 µA |
| Accuracy |
1.0% ± 5 counts |
| | Resistance |
| Range |
0 – 9999 Ω |
| Accuracy |
1.5% ± 5 counts |
| | Continuity | | Temperature* (Type K Thermocouple) |
| Range |
-10 degree C to 400 degree C (-14 degree F to 752 degree F) |
| Accuracy |
+/- 1.0% + 0.8 degree C (+/- 1.0% + 1.5 degree F) typical
|
| Range |
-40 degree C to -10 degree C (-40 degree F to -14 degree F) |
| Accuracy |
+/- 5.0% + 1.5 degree C (+/- 5.0% + 3.3 degree F) typical |
| | Capacitance |
| Range |
1-1000 µF |
| Accuracy |
1.9% ± 2 counts |
|
* Error does not include Type K Thermocouple errors
| Mechanical & General Specifications |
| Weight | | | Dimensions |
|
10.75” x 4.25” x 2.44” (27.3 cm x 10.8 cm x 6.2 cm) |
| | Battery type |
|
(2) AA Alkaline Batteries |
|
|
| Model Name | Description | Price List | | Fluke 902 |
True-rms HVAC Clamp Meter Includes:
- AA Alkaline batteries (2)
- Users manual w/safety information
- Soft carrying case
- TL75 Test Leads (1 pair)
- 80BK Integrated DMM Temperature Probe (1)
|
|
| Clips | | AC220 | AC220 SureGrip™ Alligator Clip Set | | AC285 | AC285 SureGrip™ Alligator Clip Set | | AC87 | AC87 Heavy Duty Bus Bar Clip Set | | AC89 | AC89 Heavy Duty Insulation Piercing Test Clip |
| Test Probes | | TP1 | TP1 Slim Reach Test Probe (flat blade) |
| Cases and Holsters | | C1600 | C1600 Gear Box for Meter and Accessories
| | C33 | C33 Soft Carrying Case | | C550 | C550 Tool Bag | | H3 | H3 Holster (330 Series) |
| Lights | | L206 | L206 Deluxe LED Hat Light | | LVD1 | LVD1 Volt Light |
| Temperature | | 80AK-A | 80AK-A Thermocouple Adapter | | 80PK-8 | 80PK-8 Pipe Clamp Temperature Probe (Type K) |
| Test Leads | | TL223 | TL223 SureGrip™ Electrical Test Lead Kit | | TL224 | TL224 SureGrip™ Silicone Test Lead Set | | TL71 | TL71 Test Lead Set | | TL75 | TL75 Hard Point Test Lead Set |
|
|
|
|
|
|
|
|
|
|
|
|
|
|