The fastest, one-handed tool for loop checks.
The Fluke 707 Loop Calibrator is a high performance solution for calibration, repair and maintenance of current loops. The new "Quick Click" knob making it extremely fast and easy to use. It features:
- One handed user interface with "Quick Click" detented knob
- mA sourcing, simulation and measurement
- 0.015% accuracy and 0.001 mA resolution
- Simultaneous mA and % of span display
- Selectable step or ramp outputs
- 24 V Loop supply with mA measure, including 250Ω HART resistor
- 0-28 VDC measurement to check Loop Voltage
- Easy battery exchange without opening the case
- Compact case with separate protective holster
- Three year warranty
|
|
The fast, one-handed tool for loop checks. Just click to calibrate.
This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:
- Large display and simple, quick-click interface for easy one-handed operation.
- Simultaneous mA and % readout for quick, easy interpretation of readings.
- mA accuracy of 0.015%, superior to other loop calibrators in this price range.
- 1 µA resolution for mA source, simulate and measure.
- Push button 25% steps for fast, easy linearity checks.
- 0-100% “span check” for fast confirmation of zero and span.
- Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
- 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
- Measures V dc to 28 V.
- Single 9V battery that is easily changed without braking calibration seal
- 0 - 20 mA or 4 - 20 mA default start up modes.
- Innovative output adjustment dial with 1 µA and 100 resolution.
- HART ™ mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.
|
Safety conformance
CSA C22.2 No. 1010.1:1992
|
| Specifications |
| Current Measurement |
| Range: |
0 to 24 mA |
| Resolution: |
0.001 mA |
| Accuracy: |
0.015% Rdg + 2 LSD |
| | Current Sourcing |
| Range: |
0 to 20 mA or 4 to 20 mA |
| Accuracy: |
0.015% Rdg + 2 LSD |
| Drive Capability: |
1200 Ω; 950 Ω at 20 mA in HART mode |
| | Current Simulation |
| Range: |
0 to 20 mA or 4 to 20 mA |
| Accuracy: |
0.015% Rdg + 2 LSD |
| Ext. loop voltage requirement: |
12-30 V |
| | Loop Power | | | Voltage measurement |
| Range: |
0 to 28 V DC |
| Resolution: |
1 mV |
| Accuracy: |
0.015% Rdg + 2 LSD |
|
| Environmental Specifications |
| Operating Temperature | | | Storage Temperature | | | Humidity (Without Condensation) |
|
0 to 90% (0ºC to 35ºC); 0 to 70% (35ºC to 55ºC) |
| | Temperature Coefficient |
|
-10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC |
|
| Safety Specifications |
| Safety |
|
CSA C22.2 No. 1010.1:1992 |
| | EMC |
|
EN50082-1:1992 and EN55022:1994 Class B |
| | Maximum voltage | |
| Mechanical & General Specifications |
| Size | | | Weight |
|
224 g (340 g including holster) |
| | Batteries | | | Warranty | | | Shock & Vibration |
|
per MIL-T-28800 for a Class 2 Instrument |
| | Display current and % of span | | | Auto step, auto ramp | | | Span Check | |
|
| Model Name | Description | Price List | | Fluke 707 |
Loop Calibrator including:
- AC70A Alligator Clips
- C10 protective yellow holster with Flex-Stand™
- Instruction sheet
- TL75 safety-designed test lead set
- NIST- traceable calibration report and data
|
|
| Cases and Holsters | | C10 | C10 Meter Holster |
| Clips | | AC220 | AC220 SureGrip™ Alligator Clip Set | | AC280 | AC280 SureGrip™ Hook Clips | | AC283 | AC283 SureGrip™ Pincer Clips | | AC285 | AC285 SureGrip™ Alligator Clip Set | | AC87 | AC87 Heavy Duty Bus Bar Clip Set | | AC89 | AC89 Heavy Duty Insulation Piercing Test Clip | | BP980 | BP980 Double Banana Plug Kit |
| Test Probes | | TL910 | TL910 Electronic Test Probes | | TP1 | TP1 Slim Reach Test Probe (flat blade) | | TP2 | TP2 Slim Reach Test Probe (2 mm) | | TP220 | TP220 SureGrip™ Industrial Test Probes | | TP38 | TP38 Slim Reach Test Probe (insulated) | | TP4 | TP4 Slim Reach Test Probe (4 mm) | | TP74 | TP74 Lantern Tip Test Probes | | TP80 | TP80 Electronic Test Probes | | TP912 | TP912 Replacement Tips for TL910 | | TP920 | TP920 Test Probe Adapter Kit |
| Cases and Holsters | | C100 | C100 Hard Meter and Accessory Case | | C12A | C12A Soft Meter Case | | C195 | C195 Soft Case | | C25 | C25 Soft Meter Case | | C800 | C800 Hard Meter and Accessory Case |
| Test Leads, Probes and Clips | | TL80A | TL80A Basic Electronic Test Lead Set |
| Pressure | | PV350 | PV350 Pressure Vacuum Module |
| Temperature | | 80T-150UA | 80T-150U Universal Temperature Probe (for DMMs) | | 80TK | 80TK Thermocouple Module (Type K) |
| Test Leads | | H900 | H900 Test Lead Holder | | TL27 | TL27 Heavy Duty Test Lead Set | | TL220 | TL220 SureGrip™ Industrial Test Lead Kit | | TL221 | TL221 SureGrip™ Extension Lead Set | | TL222 | TL222 SureGrip™ Silicone Test Lead Set | | TL223 | TL223 SureGrip™ Electrical Test Lead Kit | | TL224 | TL224 SureGrip™ Silicone Test Lead Set | | TL238 | TL238 SureGrip™ Test Lead Set for High Energy Environments | | TL40 | TL40 Retractable Tip Test Lead Set | | TL71 | TL71 Test Lead Set | | TL75 | TL75 Hard Point Test Lead Set | | TL76 | TL76 All-in-one Test Lead Set | | TL81A | TL81A Deluxe Electronic Test Lead Set | | TL930 | TL930 Patch Cord Set (60 cm) | | TL932 | TL932 Patch Cord Set (90 cm) | | TL935 | TL935 Patch Cord Kit (60, 90, 120 cm) | | TL940 | TL940 Mini-Hook Test Lead Set | | TL950 | TL950 Mini-Pincer Test Lead Set | | TL960 | TL960 Micro-Hook Test Lead Set | | TL970 | TL970 Hook and Pincer Kit |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |