 Fluke 125 Industrial Network Test


ScopeMeter® 125: All the power of the 120-Series plus Industrial Bus Health Test capabilities and advanced power measurements on top

The compact ScopeMeter 120 Series is the rugged solution for industrial troubleshooting and installation applications. Based on the Fluke 120 series, the 125 has all the capabilities of the 124 ScopeMeter extended with the capability to measure and analyze the signal quality on the common industrial buses.

For more details on the Industrial Bus Test capabilities of the 125, scroll through this section. For the more generic ScopeMeter capabilities, see the ScopeMeter 120 Series section – click here.

Additional features of the Fluke 125

bushealth

The Fluke 125 is based on the Fluke 124 and includes all the functions and capabilities of that instrument. On top, a Bus Health Test mode allows for an analysis of the signal quality on industrial buses and networks, comparing measured signals to the standards’ signal requirements.

This section presents the Bus Health Test capabilities of the 125 specifically. For the general test capabilities, see the Fluke 124 pages – click here.

Fluke 125 is the ScopeMeter of choice for the maintenance engineer who deals with industrial machinery and the industrial network connecting his machinery the like. The Fluke 125 has all the functionality of the 124 plus it comes with the following extensions:

 

125 Bus

  • Bus Health mode gives a clear “Good” / “Weak” / “Bad” indication for the electrical signals on industrial buses and networks, such as CAN-bus, Profi-bus, RS-232 and many more. The Fluke 125 validates the quality of the electrical signals as soon as any electrical signals are passed along the network. It checks the signal levels and speed, transition times and distortion, and compares these to the appropriate standards to help you find errors like improper cable connections and terminators. It helps you find the source of error in case communication comes to a halt. All the commonly found industrial network types are supported!

The 125 also offers advanced power measurements for single phase and balanced 3-phase systems, a Harmonics Mode and more. For further details on these electrical tests, see the description of the Fluke 125 as it is given with the 120-series here.

For Fluke 125, the full specifications of the Fluke 124 applies. On top, the Bus Health Test capability is included, as specified below. For further details on the general specification of the 125, refer to the 123/124 section – click here.

Specifications
Bandwidth
 40 MHz
Sample Rate:
 2.5 GS/s repetitive sampling
 25 MS/s single shot sampling

Bus Health Test functions
Bus Health test:
 Verifies the electrical parameters of industrial bus systems using automatic measurement and analysis functions. Next to that, an Eyepattern mode is provided for visual inspection of signal quality.
Parameter classification:
 Default values:
 well within limits = ‘good’
 within certain percentage of the limit values = ‘weak’
 beyond limit values = ‘bad’
 Limits values, as a default, are based on industry standard for the selected bus type or may be set by the user.
Bus systems supported:
 AS-i (EN50295, 166 kb/s);
 CAN-bus (ISO-11898, up to 1 Mb/s);
 Interbus S (EIA-485, 500 kb/s);
 ControlNet (61158 type 2, 5Mb/s);
 Modbus (EIA-232 up to 115 kb/s and EIA-485 up to 10 Mb/s);
 Foundation Fieldbus H1 (61158 type 1, 31.25 kb/s);
 Profibus DP (EIA-485 up to 10 Mb/s);
 Profibus PA (61158 type 1, 31.25 kb/s);
 Ethernet 10Base2 (coaxial);
 Ethernet 10BaseT (UTP, 10 Mb/s);
 RS-232 (EIA-232, up to 115 kb/s);
 RS-485 (EIA-485, up to 10 Mb/s);
 user defined single wire or balanced system.
Modes:
 Waveform Parameter analysis with automatic read-out and parameter validation (good / weak / bad); test limits are based on industry standards or may be set by the user.
 Eyepattern display mode.
Measured parameters (where applicable):
 baud rate,
 risetime,
 fall time,
 high level,
 low level,
 bias voltage level,
 signal amplitude,
 distortion,
 jitter.
Eyepattern display mode:
 Gives waveform display of bus signals with display persistence. Timebase and attenuator settings may be altered by the user.

Additional Power measurement capabilities (Fluke 125 only)
Measurement types:
 Watt,
 VA,
 VAR,
 Power Factor (PF)
Power configuration:
 Single phase or balanced three-phase (delta-configuration) mains supply
Voltage measurement
 Channel A; using STL120, voltage probe or direct input
Current measurement
 Channel B, using i400s (included) or other compatible current clamp
Current Clamp or Shunt sensitivity:
 0.1 / 1 / 10 / 100 / 1000 mV/A, 10 mV/mA and 400 mV/A.

Harmonics Mode (Fluke 125 only)
 
 Converts waveform information into a harmonics display (using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic
Analyzed waveform:
 Voltage waveform(Ch.A), Current wavefrom (Ch.B) or Power (Ch.A x Ch.B), automatically generated.
Harmonics Frequency range:
 DC up to 33rd harmonic (for fundamental up to 60 Hz);
 DC up to 24th harmonic (for fundamental up to 400 Hz).
Display
 Bargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental
Measurements:
 Relative amplitude of individual harmonics;
 THD in %r or %f.
Model NameDescription
Fluke 125 Industrial ScopeMeter (40 MHz) with Bus Health Test

All models include:
  • STL120 Shielded Test Lead Set
  • HC120 Hook Clips
  • BB120 Shielded BNC adapter
  • AC120 Alligator clips
  • PM8907 Battery Charger/Line Voltage Adapter
  • BP120MH – NiMH Battery Pack (installed)
  • Getting started booklet
  • User manual (CD-ROM), multi-lingual
Fluke 125/124 models also include:
  • VPS40 Voltage Probe, 40 MHz, 10:1
Fluke 125 models also include:
  • I400s AC Current Clamp

Fluke 125/S Industrial ScopeMeter (40 MHz) with Bus Health Test, with SCC120 kit

SCC120 kit consists of :
  • C120 Hard Case
  • OC4USB Interface Cable
  • SW90W FlukeView ScopeMeter Software

For an overview of all models of the Fluke 120 Series, click here.


Clips
AC120AC120 Alligator Clip Set for 120-series (1 red, 1 grey, 1 black)
HC120HC120 Hook Clips (Set of 2: Red, Gray)

Test Probes
DP120DP120 Differential Voltage probe
ITP120ITP120 Optically Isolated External Trigger Probe
PM8918/301PM8918/301 ScopeMeter Low Pass Filter Probe

Automotive Accessories
SCC128SCC128 Automotive Troubleshooting kit (120 Series)

Batteries, Chargers & Adapters
BHT190BHT190 – Break-out adapters for Industrial Bus connections
BP120MHBP120MH NiMH Battery Pack for Fluke 120 series, Fluke 43 and 43B
PM8907PM8907 Line Voltage Adapter/Battery Charger

Cables & Hardware
OC4USBOC4USB USB interface cable
PAC91PAC91 Printer Adapter Cable
PM9091PM9091/001 Coaxial BNC cable set, color coded, 3 pcs, 1.5m each

Cases and Holsters
C120C120 Hard Case
C125C125 Soft Meter Case
C75C75 Accessory Case

Current clamps
80i-110s80i-110s AC/DC Current Probe (100 A)
CS20MACS20MA Current Shunt, 4~20 mA, 30V CAT III
i30sFluke i30s AC/DC Current Clamp
i1000si1000s AC Current Clamp (1000 A)
i1010i1010 AC/DC Current Clamp
i200si200s AC Current Clamp
i3000si3000s AC Current Clamp
i3000s Flex-24i3000s Flex-24 AC Current Clamp, 610 mm (24 in.)
i3000s Flex-36i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)
i310si310s Current Probe
i400si400s AC Current Clamp
i410i410 AC/DC Current Clamp
i5Si5S AC Current Clamp

Fiber Optics
FOM Fiber Optic Meter FOM Fiber Optic Meter

Options
BB120BB120 Shielded Banana to Female BNC Adapter
SCC120SCC120 Special Value Kit consisting of FlukeView Software, Carrying Case and Optically Isolated USB Interface Cable

Software
SW90WSW90W FlukeView ScopeMeter Software

Pressure
PV350PV350 Pressure Vacuum Module

Temperature
80PK-2280PK-22 Immersion Probe
80PK-2480PK-24 Air Probe
80PK-2680PK-26 General Purpose Probe
80PK-3A80PK-3A Surface Probe (Type K)
80PK-880PK-8 Pipe Clamp Temperature Probe (Type K)
80T-150UA80T-150U Universal Temperature Probe (for DMMs)
80TK80TK Thermocouple Module (Type K)
Related Products
 