Need more hours in your day?Save time by NOT breaking the loop on 4-20 mA signal measurements. Are you spending time: - Taking mA measurements by removing a wire and breaking the loop
- Calling the control room to isolate a loop
- Testing analog input/output on a console
- Troubleshooting devices with mA inputs and outputs
- Repairing intermittent or erratic 4-20 mA loops
- Going back to the shop to get extra tools
If you need more time in your busy day take a good look at the Fluke 771 mA Clamp Meters. It’s designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system. Here are some specific ways the Fluke 771 Clamp Meters will help you:
Milliamp Clamp Features |
Application |
How it saves time and money |
Measure mA signals for PLC and control system analog I/O without breaking the loop. |
Measures low level dc current |
Correlate process indication with real physical value |
Measure output signals from transmitters without breaking the loop |
Maintain and troubleshoot process and automation equipment without breaking the loop |
No disruption to the process |
Detachable clamp with extension cable |
Measurements in tight locations |
Enables measurements in difficult situations |
Measurement Spotlight |
Illuminates hard to see wires in dark enclosures |
Measurement process is easier and quicker |
Measure up to 99.9 mA range non-contact |
Wide range of measurements |
Measures 10 to 50 mA signals in older control systems |
Automatic power off |
After 15 minutes and 2 minute automatic off for backlight and spotlight |
Saves battery life |
|
The 771 mA Clamp Meter features: - Best in class 0.2 % accuracy
- 0.01 mA resolution and sensitivity
- Measure 4 to 20 mA signals without ”breaking the loop”
- Measure mA signals for PLC and control system analog I/O
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight illuminates hard to see wires in dark enclosures
- Detachable clamp with extension cable for measurements in tight locations
- Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically change the 4 to 20 mA output for remote testing
- Power saving features, auto-off, backlight timeout extend battery life
- Hold function captures and displays changing measurements
What’s the difference between the 77X models?
| . |
Fluke-771 |
Fluke-772 |
Fluke-773 |
| . |
Non-contact mA loop measurement |
Integrated mA loop troubleshooting |
Advanced process troubleshooting |
| mA measure, jaw |
 |
 |
 |
| mA measure, in circuit |
. |

|
 |
| Loop power |
. |

|

|
| mA source |
. |

|

|
| DCV measure |
. |
. |

|
| DCV source |
. |
. |

|
| mA scaled output |
. |
. |

|
| mA in / out |
. |
. |

|
|
Specifications |
| Diameter of measurable conductor |
0.177” or 4.5 mm max |
| Operating temperature |
-10 to 50 ºC |
| Storage Temperature |
-25 to 60ºC |
| Operating Humidity |
< 90% @ <30 ºC, < 75% @ 30 to 55ºC |
| Operating Altitude |
0 to 2000 m |
| IP Rating |
IP 40 |
| Size |
59 x 38 x 212 mm, (2.32 x 1.5 x 8.35 in.) |
| Weight |
260G, (9.1 oz.) |
| Vibration |
Random 2 g, 5 to 500 Hz |
| Shock |
1 meter drop test (except the jaw) |
| EMI/RFI |
Meets EN61326-1 Note: For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m. |
| Temperature Coefficient |
0.01% ºC (<18? or > 28?) |
| Power, battery life |
(2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical |
| Warranty |
Three years for electronics one year for cable and clamp assembly |
| mA measurement (Measured by clamp) |
Resolution and Range: 0 to 20.99 mA Accuracy: 0.2% +2 counts Resolution and Range: 21.0 mA to 100.0 mA Accuracy: 1% + 5 counts |
|
| Nome do modelo | Descrição | Preço | | Fluke 771 |
Pinça Amperimétrica de Processos de Miliamperes
Acessórios incluídos:
- Mala de transporte flexível
- Manual do utilizador
|
| A pedido |
|
|
|
|