The first four- and two-channel scopes built for CAT IV industrial environments
  • Extend your arsenal of troubleshooting capabilities by visually inspecting signals amplitude, time, shape and disturbance or distortion characteristics.
  • The Fluke 190 series combines the power of a high performance oscilloscope, multimeter and paperless recorder in an easy to use test tool you will come to rely on in the field.
Contact Me
Fluke 190 Series II ScopeMeter® Test Tool
Fluke 190 Series II ScopeMeter® Test Tool
Fluke 190 Series II ScopeMeter® Test Tool
Fluke 190 Series II ScopeMeter® Test Tool
Fluke 190 Series II ScopeMeter® Test Tool

Fluke 190 Series II - 20 years of ScopeMeter® Test Tool Innovation.

As the first two and four-channel portable scopes safety rated CAT III 1000V / CAT IV 600V, the Fluke ScopeMeter® 190 Series II combines an unprecedented level of performance, ruggedness, and portability. You can choose from 60MHz, 100MHz, 200MHz or 500MHz bandwidth models, with real-time sampling rates up to 5 GS/s and 200 ps resolution to capture noise and other disturbances. All models feature deep memory—up to 10,000 samples per channel— so you can examine very small parts of the waveform in detail. And all models are IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter test tools are hand-held battery operated, designed to meet the demands of field service professionals.

See More, Fix More with the Two and Four-Channel CAT IV Rated Fluke ScopeMeter 190 Series II

The Fluke ScopeMeter 190 Series II combines the highest safety ratings and rugged portability with the high performance of a bench oscilloscope. Designed for plant maintenance engineers and technicians, these tough ScopeMeter test tools go into harsh, dirty, and hazardous industrial conditions to test everything from microelectronics to power electronics applications.

The 190 Series II is the one test tool you will reach for to tackle just about any troubleshooting task. They include a multimeter, TrendPlot™ and ScopeRecord™ roll paperless recorder modes and hands free operation with Connect-and-View™ triggering, and much more:

  • Two or four electrically isolated inputs
  • CAT III 1000V / CAT IV 600V safety rated
  • Choose from 60 MHz, 100MHz, 200MHz or 500MHz bandwidth models
  • Fast sampling rate, up to 5GS/s with up to 200 ps resolution (Depending on model and channels used)
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 5000 Count digital multimeter in two-channel models
  • Four meter measurements via scope BNC inputs in four-channel models
  • Connect-and-View™ continuous auto-trigger, single shot, pulse width, and video triggering
  • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP-51 rated for dust and drip proof to withstand harsh environments
  • Isolated USB ports for memory devices and PC connectivity
  • Li-Ion battery for extended operating timespan:
    • 190-X04, four-channel models up to 7 hour (BP291 included standard)
    • 190-X02, two-channel models up to 4 hours (BP290 included standard) or up to 8 hour with optional BP291
    • Charge spare battery using optional external battery charger EBC290
  • Easy-access battery door to make it easy to swap batteries
  • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock

Gain Four Times the Diagnostic Power Plus CAT IV Safety Rating

The Fluke ScopeMeter 190 Series II portable scopes are double-insulated two and four-channel floating oscilloscopes, safety rated for measurements in CAT III 1000V/CAT IV 600V environments.

Three-dimensional Testing for Industrial Systems

Three-dimensional Testing for Industrial Systems »

Inspect input signals, output feedback loops or safety interlocks simultaneously to find a range of problems including:
  • Circuit voltage/current overloading
  • Signal timing measurements and synchronization issues
  • Attenuation/input impedance mismatch
  • Signal fluctuation/drift
Three-phase Testing for Diagnosing Vsd, Power Inverters, and Converters

Three-phase Testing for Diagnosing Vsd, Power Inverters, and Converters »

  • Test for harmonics, transients and loads at the three-phase power input
  • Troubleshoot dc to ac converters for faulty IGBT gates or filter circuits
  • Test PWM output for reflections and transients or voltage unbalance
Safely Measure from mV to kV

Safely Measure from mV to kV

Standard probes that cover a wide application range from mV to kV prepare you for anything from micro-electronics to heavy duty medium voltage electrical applications. Independent isolated inputs eliminate the risk of accidental ground short circuits by allowing you to make measurements in mixed circuits with separate ground references.

Take on the Harshest Conditions with the Only IP-51-rated According to IEC60529 Scope on the Market

Rugged and shock-proof, all ScopeMeter portable oscilloscopes are built for harsh environments. Their sealed cases protect them from dust, water vapor, drips, humidity and airborne pollutants, ensuring reliable and accurate performance every time you need them.
Built in Digital Multimeter to Quickly and Conveniently Perform Precise Measurements

Built in Digital Multimeter to Quickly and Conveniently Perform Precise Measurements

Built-in digital multimeter 190 Series II two-channel models with isolated dual input scope and dedicated digital multimeter. Conveniently switch from waveform analysis to precise multimeter measurements using the built in 5000 count digital multimeter. Measurement functions include Vdc, Vac, Vac+dc, resistance, continuity and diode test. Measure current and temperature using a suitable shunt, probe or adapter with wide range of scaling factors. The Fluke-190-X04, four-channel models incorporate four meter measurements via the four-channel scope BNC inputs.
Work a Full Shift on a Single Charge

Work a Full Shift on a Single Charge

New high-performance batteries take advantage of Li-Ion technology to keep you going strong for up to seven hours in four-channel models or up to four hours in two-channel models (up to 8 hours using the optional BP291 battery pack). And with the easy-access battery door you can make battery swaps fast.
Capture and Share Waveforms Easily with New USB Connectivity

Capture and Share Waveforms Easily with New USB Connectivity

Two USB ports, electrically isolated from measurement input circuits offer you easy USB connectivity to a PC or USB memory devices. Store unlimited waveforms, screen captures or instrument setups to a USB memory device. Connect to a PC USB interface to transfer and archive critical measurement data using FlukeView software for windows.
See a Stable Display Instantly with Connect-and-View™ Triggering

See a Stable Display Instantly with Connect-and-View™ Triggering

Connect-and-View™ automatically sets up correct triggering by recognizing signal patterns. Without touching a button, you get a stable, reliable, and repeatable display of virtually any signal including motor drive and control signals. Expedites measuring several test-points in rapid succession.
Record Up to 48 Hours of High-Resolution Waveforms with ScopeRecord™

Record Up to 48 Hours of High-Resolution Waveforms with ScopeRecord™

ScopeRecord memory stores up to 30,000 data points per channel, capturing intermittents and fast glitches.
  • Stores events like motion profiles, UPS power up signals, power supply AC and DC signals, and motor start-ups
  • With the Stop-on-Trigger mode, the ScopeMeter 190 series II automatically recognizes a power failure and stores the waveform data preceding it
  • With the waveform zoom you can look at the smallest details like individual power cycles
Record up to 22 Days with Trendplot™ Paperless Recorder to Find Intermittent Faults

Record up to 22 Days with Trendplot™ Paperless Recorder to Find Intermittent Faults

Intermittent faults can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Line outages, sags, or starting and stopping a motor can also cause a machine to stop. The TrendPlot function in the Fluke ScopeMeter test tool helps find those faults by:
  • Plotting minimum and maximum peak values and average over time up to 22 days
  • Plotting any combination of voltages, amps, temperature, frequency and phase for all four inputs, all with time and date stamp to pinpoint faults

Specifications

Bandwidth Fluke 190-504: 500 MHz
Fluke 190-204: 200 MHz
Fluke 190-202: 200 MHz
Fluke 190-104: 100 MHz
Fluke 190-102: 100 MHz
Fluke 190-062: 60 MHz
Number of channels Fluke 190-504: 500 MHz: 4 channels
Fluke 190-204: 200 MHz: 4 channels
Fluke 190-202: 200 MHz: 2 channels
Fluke 190-104: 100 MHz: 4 channels
Fluke 190-102: 100 MHz: 2 channels
Fluke 190-062: 60 MHz: 2 channels
Real-time sample rate Fluke 190-504: 5 GS/s
Fluke 190-204: 2.5 GS/s
Fluke 190-202: 2.5 GS/s
Fluke 190-104: 1.25 GS/s
Fluke 190-102: 1.25 GS/s
Fluke 190-062: 625 MS/s
Inputs Fluke 190-X04: 4x BNC input for scope and meter measurements
Fluke 190-X02: 2x BNC input plus 1x DMM input
Independently floating isolated inputs Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground
Timebase range 1 ns/div to 4s/div (190-504, 500 MHz model)
2 ns/div to 4s/div (190-20X, 200 MHz models)
5 ns/div to 4s/div (190-10X, 100 MHz models)
10 ns/div to 4s/div (190-062, 60 MHz model)
Input sensitivity 2 mV-100 V/div plus variable attentuation
Trigger types Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
Trigger source Fluke 190-X02: 2x BNC input or external via DMM input
Fluke 190-X04: 4x BNC input
Glitch capture 8 ns
Scope measurements Cursor: 7
Automatic: 30
Maximum record length ScopeRecord mode: 30,000 pts per input
Scope mode: 10,000 pts per input
Persistence Digital persistence giving analog oscilloscope-like waveform decay
Waveform compare Waveform reference with automatic Pass/Fail testing

DMM Specifications (Two-Channel Models)

Meter inputs
(also used as External Trigger Input for the Oscilloscope Mode)
4 mm banana inputs, fully isolated from scope inputs and from scope ground
Maximum resolution 5000 counts
Measurements Vdc, Vac rms, Vac+dc rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature ºC or ºF (using optional converter)
Memory locations Screen + Setup: 30 Waveform memories plus 10 recording memories plus 9 screencopy memories.
Display 153 mm full color LCD with fast update rate

Environmental Specifications

Operating temperature 0ºC to 40ºC Including Batteries
0ºC to 50ºC Excluding Batteries
Storage temperature -20°C to +60°C
Operating altitude Up to 2,000 m (6666 ft) for CAT IV 600 V/ CAT III 1,000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V/ CAT II 1,000 V

Safety Specifications

Electrical safety 1,000V CAT III/600V CAT IV (EN61010-1)

Mechanical and General Specifications

Size 270 x 190 x 70 mm
Weight 2.2 kg
Warranty Three-years on main instrument
Li-Ion battery Fluke 190-XX2: BP290 (2400mAh)
Fluke 190-XX4: BP291 (4800mAh)
Model NameDescription
Fluke-190-504/SColor ScopeMeter, 500 MHz, 4 channels plus DMM/Ext.input, with SCC-290 Kit
Fluke-190-504Color ScopeMeter, 500 MHz, 4 channels plus DMM/Ext.input
Fluke-190-502Color ScopeMeter, 500 MHz, 2 channels plus DMM/Ext.input
Fluke-190-502/SColor ScopeMeter, 500 MHz, 2 channels plus DMM/Ext.input, with SCC-290 Kit
Fluke-190-062

Color ScopeMeter, 60 MHz, 2 channels plus DMM/Ext.input

Fluke-190-062/S

Color ScopeMeter, 60 MHz, 2 channels plus DMM/Ext.input, with SCC-290 Kit

Fluke-190-102

Color ScopeMeter, 100 MHz, 2 channels plus DMM/Ext.input

Fluke-190-102/S

Color ScopeMeter, 100 MHz, 2 channels plus DMM/Ext.input with SCC-290 Kit

Fluke-190-104Color ScopeMeter, 100 MHz, 4 channels plus DMM/Ext.input
Fluke-190-104/SColor ScopeMeter, 100 MHz, 4 channels plus DMM/Ext.input with SCC-290 Kit
Fluke-190-202

Color ScopeMeter, 200 MHz, 2 channels plus DMM/Ext.input

Fluke-190-202/S

Color ScopeMeter, 200 MHz, 2 channels plus DMM/Ext.input, with SCC-290 Kit

Fluke-190-204Color ScopeMeter, 200 MHz, 4 channels plus DMM/Ext.input
Fluke-190-204/SColor ScopeMeter, 200 MHz, 4 channels plus DMM/Ext.input, with SCC-290 Kit

 

Included Accessories

Two-channel models VPS410 Voltage Probe Sets (one red, one blue)
TL175 TwistGuard™ Safety Designed Test Lead Set (red and black)
BC190 Battery Charger/Mains Adapter
BP290 2400 mAh Li-Ion Battery
Handstrap (affixed to instrument)
Hangstrap
Multi-Language User Manuals on CD-Rom
FlukeView ScopeMeterDdemo Package (restricted functionality)
USB Interface Cable
Four-channel models VPS410 Voltage Probe Sets (one red, one blue, one grey, one green)
BC190 Battery Charger/Mains Adapter
BP291 4800 mAh High Capacity Li-Ion Battery
Handstrap (affixed to instrument)
Hangstrap
Multi-Language User Manuals on CD-Rom
FlukeView ScopeMeter Demo Package (restricted functionality)
USB Interface Cable
Warranty One year on accessories

Options
CS20MACS20MA Current Shunt

Accessory Kits
MA190MA190 Accessory kit for medical and video applications.

Batteries, Chargers and Adapters
BP2902400 mAh Li-ion battery for Fluke 190 Series II
BP2914800 mAh High capacity Li-ion battery ) for Fluke 190-seriesII
BC190BC190 Line Voltage Adapter / Battery Charger
EBC290External Battery Charger for charging BP290 or BP291 outside the instrument

Cases and Holsters
C195C195 Case
SCC290FlukeView Software for ScopeMeter (SW90W) and Carrying Case (C290) Kit
C290Hard Shell Protective Carrying Case for Fluke 190-series II

Current Clamps
80i-110s80i-110s AC/DC Current Clamp
i1010i1010 AC/DC Current Clamp
i30sFluke i30s AC/DC Current Clamp
i400si400s AC Current Clamp
Fluke i410AC/DC Current Clamp
i1000si1000s AC Current Probe
i2000 flexi2000 flex AC Current Clamp
i200si200s AC Current Clamp
i3000si3000s AC Current Clamp
i5Si5S AC Current Clamp
i6000sFlexi6000sFlex AC Current Probe

Options
HH290Hanging Hook for ScopeMeter 190-Series II

Software
SW90WSW90W FlukeView ScopeMeter Software (full version)

Test Leads, Probes and Clips
AS400AS400 Probe accessory extension set
PM9093PM9093 Male BNC to Dual Female BNC Adapter
PM9096/201PM9096/201 Secondary Ignition Pickup, 1000:1
RS400RS400 Probe Accessory Replacement Set
RS500Probe Accessories Replacement Set
VPS410-BScopeMeter Voltage Probe-set, blue, 10:1, 300 MHz, 1000V CAT III, 600V CAT IV
VPS410-VScopeMeter Voltage Probe-set, green, 10:1, 300 MHz, 1000V CAT III, 600V CAT IV
VPS410-GScopeMeter Voltage Probe-set, grey, 10:1, 300 MHz, 1000V CAT III, 600V CAT IV
VPS410-RScopeMeter Voltage Probe-set, red, 10:1, 300 MHz, 1000V CAT III, 600V CAT IV
TRM50Coaxial Feed-through BNC Male to BNC Female Cable Terminator. Consists of Set of 2, 50Ohm, 1000V CAT III, Max Power 1W
VPS101VPS101 – Voltage Probe Set, 1:1, one black
VPS410-II-BScopeMeter Industrial Voltage Probe-set, blue, 10:1, 500 MHz
VPS410-II-GScopeMeter Industrial Voltage Probe-set, grey, 10:1, 500 MHz
VPS410-II-RScopeMeter Industrial Voltage Probe-set, red, 10:1, 500 MHz
VPS410-II-VScopeMeter Industrial Voltage Probe-set, green, 10:1, 500 MHz
VPS420-BRuggedized High-Working ScopeMeter Voltage Probe-set, blue/black, 100:1, 150 MHz, 1000V CAT III / 600V CAT IV, working voltage (voltage between probe tip and reference lead): 2000V CAT III / 1200V CAT IV.
VPS420-GRuggedized High-Working ScopeMeter Voltage Probe-set, grey/black, 100:1, 150 MHz, 1000V CAT III / 600V CAT IV, working voltage (voltage between probe tip and reference lead): 2000V CAT III / 1200V CAT IV.
VPS420-RRuggedized High-Working ScopeMeter Voltage Probe-set, red/black, 100:1, 150 MHz, 1000V CAT III / 600V CAT IV, working voltage (voltage between probe tip and reference lead): 2000V CAT III / 1200V CAT IV.
VPS420-VRuggedized High-Working ScopeMeter Voltage Probe-set, green/black, 100:1, 150 MHz, 1000V CAT III / 600V CAT IV, working voltage (voltage between probe tip and reference lead): 2000V CAT III / 1200V CAT IV.
VPS510-BScopeMeter® Compact Probe for electronic applications, blue, 10:1, 500 MHz, 300 V CAT III
VPS510-GScopeMeter® Compact Probe for electronic applications, grey, 10:1, 500 MHz, 300 V CAT III
VPS510-RScopeMeter® Compact Probe for electronic applications, red, 10:1, 500 MHz, 300 V CAT III

Pressure
PV350PV350 Pressure Vacuum Module

Test Leads
TL175TL175 TwistGuard™ Test Leads
TL220

SureGrip™ Industrial Test Lead Set includes:

  • AC220 SureGrip™ Alligator Clip Set
  • TP220 SureGrip™ Industrial Test Probe Set
  • TL224 SureGrip™ Silicone Test Lead Set (straight to right)
  • One year warranty
TL224TL224 SureGrip™ Insulated Test Leads
STL120-IIISTL120-III Shielded Test Leads Set
TL910TL910 Electronic Test Probe Set
SA Certification   UL Certification
        
Related Products
 
 Hard Shell Protective Carrying Case for Fluke 190-series II »
 
 PM9082 Dual Banana Jack (female) to male BNC Adapter »
 
 VPS420-B ScopeMeter Voltage Probe Set  »
Home   |   Site Map   |   Fluke Corporation   |   Safety Notices
Privacy Statement   |   Terms of Use   |   Terms and Conditions of Sale   |  Terms and Conditions of Service
© 1995 - 2017 Fluke Corporation