Middle East [Change]  |  Fluke [Change Company]
fluke
Home  |  Products  |  Process Calibration Tools  |  Loop Calibrators  |  
Contact usRefer this page

Fluke 707Ex Intrinsically Safe Loop Calibrator

Contact Me
Request A Demo
 Fluke 707EX
The fast one-handed tool for mA loop checks in Ex zones

The 707Ex is an intrinsically safe loop calibrator for use in explosion endangered areas. The Fluke 707Ex is certified in accordance with the ATEX directive (Ex II 2 G Ex ia IIC T4) in Zones 1 and 2.

  • Large display and simple, quick-click push rotary button for easy one-handed operation
  • Simultaneous mA and % readout for quick, easy, interpretation of readings.
  • mA accuracy of 0.015%, superior to other loop calibrators
  • 1 µA resolution for mA source, simulate and measure
  • Push button with 25% steps for fast, easy linearity checks
  • 0-100% "span check" for fast confirmation of zero and span
  • Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests
  • Internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
  • Measures Vdc to 28 V
  • Single 9 V battery that is easily changed
  • 0-20 mA or 4-20 mA default start up modes
  • Innovative output adjustment dial with 1 µA and 100 µA resolution
  • HART® compatible resistance is connected in series with the loop supply for compatibility with HART communicators
Specifications
Current Measurement
Range:  0 to 24 mA
Resolution:  0.001 mA
Accuracy:  0.015% Rdg + 2 LSD
Current Sourcing
Range:  0 to 20 mA or 4 to 20 mA
Accuracy:  0.015% Rdg + 2 LSD
Drive Capability:  700 Ω at 20 mA
Current Simulation
Range:  0 to 20 mA or 4 to 20 mA
Accuracy:  0.015% Rdg + 2 LSD
Loop Power
 While measuring mA, 24 V
Voltage measurement
Range:  0 to 28 V DC
Resolution:  1 mV
Accuracy:  0.015% Rdg + 2 LSD

Environmental Specifications
Operating Temperature
 -10ºC to 55ºC
Storage Temperature
 -40ºC to 60ºC
Humidity (Without Condensation)
 0 to 95% (0ºC to 30ºC);
 0 to 75% (30ºC to 40ºC)
 0 to 45% (40ºC to 50ºC)
Temperature Coefficient
 -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC

Safety Specifications
Safety
 CSA C22.2 No. 1010.1:1992
EMC
 EN50082-1:1992 and EN55022:1994 Class B
Maximum voltage
 30 V
ATEX certification
 Ex II G Ex ia IIC T4 Zones 1 and 2, ZELM 02 ATEX 0120 X
CE certification
 EN61010-1 and EN61326

Mechanical & General Specifications
Size
 152 x 70 x 41 mm
Weight
 224 g (350 g including holster)
Batteries
 One 9V battery Alkaline
Warranty
 3 year
Shock & Vibration
 per MIL-T-28800 for a Class 2 Instrument
Display current and % of span
 Yes
Auto step, auto ramp
 Yes
Span Check
 Yes

Model NameDescriptionPrice List
Fluke 707Ex Intrinsically safe loop calibrator
  • Alligator test clips
  • Instruction manual (on CD-ROM)
  • Protective holster with Flex-Stand™
  • Safety designed test leads
  • NIST- traceable calibration report and data
On Request

Cases and HolstersPrice List
C10C10 Meter HolsterOn Request

ClipsPrice List
AC220AC220 SureGrip™ Alligator Clip SetOn Request
AC280AC280 SureGrip™ Hook ClipsOn Request
AC283AC283 SureGrip™ Pincer ClipsOn Request
AC285AC285 SureGrip™ Alligator Clip SetOn Request
AC87AC87 Heavy Duty Bus Bar Clip SetOn Request
AC89AC89 Heavy Duty Insulation Piercing Test ClipOn Request
BP980BP980 Double Banana Plug KitOn Request

Test ProbesPrice List
TL910TL910 Electronic Test ProbesOn Request
TP1TP1 Slim Reach Test Probe (flat blade)On Request
TP2TP2 Slim Reach Test Probe (2 mm)On Request
TP220TP220 SureGrip™ Industrial Test ProbesOn Request
TP38TP38 Slim Reach Test Probe (insulated)On Request
TP4TP4 Slim Reach Test Probe (4 mm)On Request
TP74TP74 Lantern Tip Test ProbesOn Request
TP80TP80 Electronic Test ProbesOn Request
TP912TP912 Replacement Tips for TL910On Request
TP920TP920 Test Probe Adapter KitOn Request

Cases and HolstersPrice List
C100C100 Hard Meter and Accessory CaseOn Request
C12AC12A Soft Meter CaseOn Request
C195C195 Soft Case On Request
C25C25 Soft Meter CaseOn Request
C800C800 Hard Meter and Accessory CaseOn Request

Test Leads, Probes and ClipsPrice List
TL80ATL80A Basic Electronic Test Lead SetOn Request

PressurePrice List
PV350PV350 Pressure Vacuum ModuleOn Request

TemperaturePrice List
80T-150UA80T-150U Universal Temperature Probe (for DMMs)On Request
80TK80TK Thermocouple Module (Type K)On Request

Test LeadsPrice List
H900H900 Test Lead HolderOn Request
TL27TL27 Heavy Duty Test Lead SetOn Request
TL220TL220 SureGrip™ Industrial Test Lead KitOn Request
TL221TL221 SureGrip™ Extension Lead SetOn Request
TL222TL222 SureGrip™ Silicone Test Lead SetOn Request
TL223TL223 SureGrip™ Electrical Test Lead KitOn Request
TL224TL224 SureGrip™ Silicone Test Lead SetOn Request
TL238TL238 SureGrip™ Test Lead Set for High Energy EnvironmentsOn Request
TL40TL40 Retractable Tip Test Lead SetOn Request
TL71TL71 Test Lead SetOn Request
TL75TL75 Hard Point Test Lead SetOn Request
TL76TL76 All-in-one Test Lead SetOn Request
TL81ATL81A Deluxe Electronic Test Lead SetOn Request
TL930TL930 Patch Cord Set (60 cm)On Request
TL932TL932 Patch Cord Set (90 cm)On Request
TL935TL935 Patch Cord Kit (60, 90, 120 cm)On Request
TL940TL940 Mini-Hook Test Lead SetOn Request
TL950TL950 Mini-Pincer Test Lead SetOn Request
TL960TL960 Micro-Hook Test Lead SetOn Request
TL970TL970 Hook and Pincer KitOn Request
Search Fluke
ResourcesProducts
Find Resources

Home | Site Map | Fluke Corporation  | Terms and Conditions | Privacy Statement | Disclaimer© 1995 - 2013 Fluke Corporation