This clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.
The Fluke 345 is more than an electric power meter. Combining the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device, the Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics.
One of the leading wattage meters of the world, the multi-faceted Fluke 345 is packed with features such as a bright, color display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise and a high EMC immunity design, making the Fluke 345 power analyzer ideal for troubleshooting power quality on switching loads. The internal memory of this electric power meter enables long-term power quality logging for analysis of trends or intermittent problems. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit.
Besides effectively performing basic tasks like measuring wattage, the Fluke 345 power meters offer the ease of use, portability and flexibility needed to resolve most power issues in commercial, industrial and residential settings.
- Setup and troubleshoot variable frequency drives and UPS systems - Verify correct operation by measuring key power quality parameters
- Harmonics measurements - Uncover harmonic issues that can damage or disrupt critical equipment
- Inrush capture - Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
- Load studies - Verify electrical system capacity before adding loads
|
The suggested single phase replacement is the Fluke 43B Power Quality Analyzer with an i3000s Current Clamp. If a 3-phase instrument is a better solution for your application, the 1735, 434 or 435 are suggested replacements.
|
|
- AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
- Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance
- Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter
- Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
- Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
- Troubleshoot harmonics: Analyze and log harmonics digitally or graphically
- Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds
- Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends
- 3-Phase power: Built in capability for balanced loads
- View graphs and generate reports: Use power analyzer with included Power Log software
|
|
| Display |
|
| Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight |
|
|
| Power supply |
|
|
Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6 |
| | Battery life typically |
|
> 10 hours (backlight on full) |
|
> 12 hours (backlight reduced) |
| | Battery Eliminator BE345 |
| Input |
110/230 V 50/60 Hz |
| Output |
15 V dc, 300 mA |
|
| Ambient conditions (For indoor use only) |
| Reference conditions |
|
All accuracies stated at 23˚C ± 1˚C (73.4 °F ± 1.8 °F) |
| | Operating temperature |
|
0 °C to 50 °C (32 °F to 122 °F) |
| | Temperature coefficient of current | | | Temperature coefficient of voltage | | | Maximum relative humidity |
|
80 % for temperatures up to 31 °C (87 °F) decreasing linearly to 50 % relative humidity at
40 °C (104 °F) |
| | Maximum operating altitude | |
| Electrical safety |
| Maximum safe working voltages |
|
Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2 |
| | | | Current measurement |
|
600 V ac rms or dc between uninsulated conductor and ground |
| | Voltage measurement |
|
600 V ac rms or dc between either input terminal and ground, or 825 V between energized phase voltages (delta power config.) |
|
| EMC |
| Emission |
|
IEC/EN 61326-1:1997 class A |
| | Immunity |
|
IEC/EN 61326-1:1997 Annex C Performance Criterion B |
|
| Mechanical |
| Dimensions (length x width x depth) |
|
300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) |
| | Weight including batteries | | | Jaw opening | | | Jaw capacity | | | Cleaning |
|
The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or
other solvents. |
|
| Electrical data |
| All accuracies stated at 23 °C ± 1 °C (73.4 °F ± 1.8 °F). See Ambient conditions specifications for temperature coefficients. | |
| Current measurement (dc, dc rms, ac rms) |
| Measuring range |
|
0 to 2000 A dc or 1400 ac rms |
| | Autorange facility | | | Resolution |
|
10 mA in 40 A range |
|
100 mA in 400 A range |
|
1 A in 2000 A range |
| | Accuracy: DC and dc rms |
| I > 10 A: |
± 1.5 % rdg ± 5 digits |
| I < 10 A: |
± 0.2 A |
| | Accuracy: AVG |
| I > 10 A: |
± 3 % rdg ± 5 digits |
| I < 10 A: |
± 0.5 A |
| | Accuracy: Pk |
| I > 10 A: |
± 5 % rdg ± 5 digits |
| I < 10 A: |
± 0.5 A |
| | Accuracy: AHr |
| I > 10 A: |
± 2 % rdg ± 5 digits |
| I < 10 A: |
± 0.5 AHr |
| | Accuracy: CF (Crest Factor) |
| 1.1 ≤ CF < 3: |
± 3 % rdg ± 5 digits |
| 3 ≤ CF < 5: |
± 5 % rdg ± 5 digits |
| Resolution: |
0.01 |
| | Accuracy: RPL (Ripple) |
| 2 % ≤ RPL < 100 %: |
± 3 % rdg ± 5 digits |
| 100 % ≤ RPL < 600 %: |
± 5 % rdg ± 5 digits |
| Resolution: |
0.1 % |
| Idc > 5 A, Iac > 2 A |
|
| All measurements dc and 15 Hz to 1 kHz
Maximum overload 10,000 A or rms x frequency < 400,000
Amps rms is a true-rms measurement (ac + dc) | |
| Voltage measurement (dc, dc rms, ac rms) |
| Measuring range | | | Autorange facility |
|
4 V / 40 V / 400 V / 750 V |
| | Resolution |
|
1 mV in 4 V range |
|
10 mV in 40 V range |
|
100 mV in 400 V range |
|
1 V in 750 V range |
| | Accuracy: DC and dc rms |
| V > 1 V: |
± 1 % rdg ± 5 digits |
| V < 1 V: |
± 0.02 V |
| | Accuracy: AVG |
| V > 1 V: |
± 3 % rdg ± 5 digits |
| V < 1 V: |
± 0.03 V |
| | Accuracy: Pk |
| V > 1 V: |
± 5 % rdg ± 5 digits |
| V < 1 V: |
± 0.03 V |
| | Accuracy: CF (Crest Factor) |
| 1.1 ≤ CF < 3: |
± 3 % rdg ± 5 digits |
| 3 ≤ CF < 5: |
± 5 % rdg ± 5 digits |
| Resolution: |
0.01 |
| | Accuracy: RPL (Ripple) |
| 2 % ≤ RPL < 100 %: |
± 3 % rdg ± 5 digits |
| 100 % ≤ RPL < 600 %: |
± 5 % rdg ± 5 digits |
| Resolution: |
0.1 % |
| Vdc > 0.5 V, Vac > 0.2 V |
|
| |
|
All measurements dc and 15 Hz to 1 kHz
Maximum overload 1,000 V rms
Volts rms is a true-rms measurement (ac + dc) |
|
| Harmonics |
| THD (Total Harmonic Distortion) |
| 1 % ≤ THD < 100 %: |
± 3 % rdg ± 5 digits |
| 100 % ≤ THD < 600 %: |
± 5 % rdg ± 5 digits |
| Resolution: |
0.1 % |
| | DF (Distortion Factor) |
| 1 % ≤ DF < 100 %: |
± 3 % rdg ± 5 digits |
| Resolution: |
0.1 % |
| H02 ≤ Vharm < H13: |
± 5 % ± 2 digits |
| H13 ≤ Vharm ≤ H30: |
± 10 % ± 2 digits |
| |
|
All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz)
Frequency range of fundamental F0 15 Hz to 22 Hz and 45 Hz to 65 Hz
Vacrms > 1V |
|
| Watts measurement (single- and three-phase) (dc, dc rms, ac rms) |
| Measuring range |
|
0 to 1650 kW dc or 1200 kW ac |
| | Autoranging facility |
|
4 kW, 40 kW, 400 kW, 1650 kW |
| | Resolution |
|
1 W in 4 kW |
|
10 W in 40 kW |
|
100 W in 400 kW |
|
1 kW in 1200 kW |
| | Accuracy |
|
2.5 % rdg ± 5 digits |
|
W1Ø < 2 kW ± 0.08 kW |
|
W3Ø < 4 kW ± 0.25 kW |
|
| VA measurement (single- and three-phase) (dc, dc rms, ac rms) |
| Measuring range |
|
0 to 1650 kVA dc or 1200 kVA ac |
| | Autorange facility |
|
4 kVA, 40 kVA, 400 kVA, 1650 kVA |
| | Resolution |
|
1 VA in 4 kVA |
|
10 VA in 40 kVA |
|
100 VA in 400 kVA |
|
1 kVA in 1200 kVA |
| | Accuracy |
| VA > 2 kVA: |
2.5 % rdg ± 5 digits |
| VA < 2 kVA: |
± 0.08 kVA |
|
| VAR measurement (single- and three-phase) |
| Measuring range | | | Autorange facility |
|
4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR |
| | Resolution |
|
1 VAR in 4 kVAR |
|
10 VAR in 40 kVAR |
|
100 VAR in 400 kVAR |
|
1 kVAR in 1200 kVAR |
| | Accuracy |
| VAR > 4 kVAR: |
± 2.5 % rdg ± 5 digits |
| VAR < 4 kVAR: |
± 0.25 kVAR |
| | Power factor range | |
| Power factor (single- and three-phase) |
| Measuring range |
|
0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5° capacitive to 0° and 0° to 72.5° inductive) |
| | Resolution | | | Accuracy | | | Frequency range | |
| Displacement power factor (single- and three-phase) |
| Measuring range |
|
0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5° capacitive to 0° and 0° to 72.5° inductive) |
| | Resolution | | | Accuracy | | | Frequency range |
|
15 Hz to 22 Hz and 45 Hz to 65 Hz |
|
| Kilowatt hour (kWHr) |
| Measuring range | | | Autorange facility |
|
4 kWHr, 40 kWHr, 400 kWHr, 4,000 kWHr, 40,000 kWHr |
| | Resolution |
|
1 WHr in 4 kWHr Range |
|
10 WHr in 40 kWHr Range |
|
100 WHr in 400 kWHr Range |
|
1 kWHr in 4,000 kWHr Range |
|
10 kWHr in 40,000 kWHr Range |
| | Accuracy |
| kWHr > 2 kWHr: |
± 3 % ± 5 digits |
| kWHr < 2 kWHr: |
± 0.08 kWHr |
| | All Watts /VA /VAR /PF measurements |
| Frequency range: |
DC and 15 Hz to 1 kHz |
| Current range: |
10 A to 1400 A rms |
| Voltage range: |
1 V to 825 V rms |
| Maximum input: |
825 V rms/1400 A rms |
| Maximum overload: |
1000 V rms/10,000 A All measurements dc and 15 Hz to 1 kHz. Maximum overload 10,000 A or rms x frequency < 400,000 |
|
| Frequency measurement (from current or voltage sources) |
| Measuring range | | | Resolution | | | Accuracy |
|
15 to 22 Hz ± 0.5 % rdg |
|
40 Hz to 70 Hz ± 0.5 % rdg |
|
15 Hz to 1000 Hz ± 1% rdg |
| | Current range | | | Voltage range | |
| Scope function |
| Current measurement |
| Ranges: |
10 A / 20 A / 40 A / 100 A / 200 A / 400 A / 1000 A / 2000 A |
| Resolution: |
1 A in 40 A 10 A in 400 A 50 A in 2000 A |
| Accuracy: |
± 3 % rdg ± 1 pixel |
| Maximum overload: |
10,000 A |
| | Voltage measurement |
| Ranges: |
4 V / 10 V / 20 V / 40 V / 100 V / 200 V / 400 V / 1000 V |
| Resolution: |
100 mV in 4 V 1 V in 40 V 10 V in 400 V 31.25 V in 1000 V |
| Accuracy: |
± 2 % rdg ± 1 pixel |
| Maximum overload: |
1000 V rms |
| Frequency range: |
DC and 15 Hz to 600 Hz |
| | Time base |
|
2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div |
| | Refresh rate | | | Maximum sampling rate | |
| Inrush current function |
| Ranges | | | Resolution |
|
10 mA in 40 A range |
|
100 mA in 400 A range |
|
1 A in 2000 A range |
| | Accuracy |
| I > 10 A: |
± 5 % rdg ± 1 pixel |
| I < 10 A: |
± 0.5 A |
|
All measurements dc and 15 Hz to 1 kHz |
| | Maximum overload |
|
Maximum overload 10,000 A or rms x frequency < 400,000 |
|
Amps rms is a true-rms measurement (ac + dc) |
| | Capture time |
|
1 s, 3 s, 10 s, 30 s, 100 s, and 300 s |
| | Maximum sampling rate | |
| Interface |
| | |
|
Power Log software for download, analysis and reporting |
| |
|
345 Upgrade Utility for installing a new firmware version |
|
| Logging Memory |
| Logging areas |
|
Three areas that can be used individually or combined into one large area |
| | Averaging periods |
|
1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom |
|
| Logging Times |
| Volts and current mode |
| Average time |
Logging time (1 area) |
| 1 s |
1 h 49 m |
| 2 s |
3 h 38 m |
| 5 s |
9 h 6 m |
| 10 s |
18 h 12 m |
| 30 s |
2 d 6 h 36 m |
| 1 min |
4 d 13 h 12 m |
| 5 min |
22 d 18 h 0 m |
| 10 min |
45 d 12 h 0 m |
| 15 min |
68 d 6 h 0 m |
|
Logging time (3 areas) |
| 1 s |
5 h 12 m |
| 2 s |
10 h 24 m |
| 5 s |
1 d 2 h 00 m |
| 10 s |
2 d 4 h 00 m |
| 30 s |
6 d 12 h 1 m |
| 1 min |
13 d 0 h 12 m |
| 5 min |
65 d 0 h 15 m |
| 10 min |
130 d 0 h 30 m |
| 15 min |
195 d 0 h 45 m |
| | V & A harmonics mode |
| Average time |
Logging time (1 area) |
| 1 s |
0 h 34 m |
| 2 s |
1 h 8 m |
| 5 s |
2 h 52 m |
| 10 s |
5 h 44 m |
| 30 s |
17 h 13 m |
| 1 m |
1 d 10 h 26 m |
| 5 m |
7 d 4 h 10 m |
| 10 m |
14 d 8 h 20 m |
| 15 m |
21 d 12 h 30 m |
|
Logging time (3 areas) |
| 1 s |
1 h 38 m |
| 2 s |
3 h 16 m |
| 5 s |
8 h 11 m |
| 10 s |
16 h 23 m |
| 30 s |
2 d 1 h 11 m |
| 1 m |
4 d 2 h 23 m |
| 5 m |
20 d 11 h 25 m |
| 10 m |
81 d 0 h 50 m |
| 15 m |
121 d 13 h 15 m |
| | single- and three-phase power mode |
| Average time |
Logging time (1 area) |
| 1 s |
1 h 40 m |
| 2 s |
3 h 21 m |
| 5 s |
8 h 22 m |
| 10 s |
16 h 45 m |
| 30 s |
2 d 2 h 17 m |
| 1 m |
4 d 4 h 35 m |
| 5 m |
20 d 22 h 55 m |
| 10 m |
41 d 21 h 50 m |
| 15 m |
62 d 20 h 45 m |
|
Logging time (3 areas) |
| 1 s |
4 h 47 m |
| 2 s |
9 h 34 m |
| 5 s |
23 h 57 m |
| 10 s |
1 d 23 h 54 m |
| 30 s |
5 d 23 h 25 m |
| 1 m |
11 d 23 h 25 m |
| 5 m |
59 d 21 h 5 m |
| 10 m |
119 d 18 h 10 m |
| 15 m |
179 d 15 h 15 m |
|
|
| Model Name | Description | Price List | | Fluke 345 |
Power Quality Clamp Meter
Includes:
- 345 Power Quality Clamp Meter
- Soft carrying case
- Power Log software
- Test leads
- Alligator clips
- Test probes
- USB cable
- International ac adapter / battery eliminator
- Printed English language user manual
- Multi-language manual CD
|
| On Request |
| Clips | Price List | | AC220 | AC220 SureGrip™ Alligator Clip Set | On Request |
| Test Probes | Price List | | TLK291 | TLK291 Fused test probe set | On Request | | TP1 | TP1 Slim Reach Test Probe (flat blade) | On Request | | TP220 | TP220 SureGrip™ Industrial Test Probes | On Request |
| Cases and Holsters | Price List | | C345 | C345 Soft Carrying Case | On Request | | C550 | C550 Tool Bag | On Request |
| Lights | Price List | | L200 | L200 Probe Light | On Request | | L210 | L210 Probe Light + Probe Extender | On Request |
|
|
|
|
|
|
|
|
|
 | | Search Fluke | | | | | | | | | | | | | | | | | | | | | | | | Find Resources | | | | | | | | |
|
|
|
|
| | |
|