|
|
Laboratory accuracy. Wherever you go.
The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged, handheld test tool.
|
Fluke 50 Series II products features:
- Relative time clock on MIN, MAX, and AVG provides a time reference for major events
- Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
- Measures J, K, T, and E-types of thermocouples
- Readout in ºC, ºF, or Kelvin (K)
- Splash and dust resistant case protected by impact absorbing holster
- User-friendly front panel is easy to set up and operate
- Sleep mode increases battery life; typical 1000-hour battery life
- Battery door allows easy battery replacement without breaking the calibration seal
- Optional ToolPak accessory allows the thermometer to hang from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation.
- 3 year warranty
|
The Fluke 53 II B and 54 II B include all the features listed above plus:
- Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX, or AVG.
- Additional thermocouple types R, S, and N (for a total of 7 different types)
- Recall function allows logged data to be easily reviewed on the meter display
- USB communication port allows data to be exported to optional FlukeView Forms® Temperature PC software for further analysis and graphing
- Data Logging up to 500 points of data with user adjustable recording interval
|
|
| Specifications |
| Temperature accuracy |
| Above -100 °C: |
J, K, T, E, and N-type: ±[0.05% + 0.3°C]*
|
|
R and S-type: ±[0.05% + 0.4°C]* |
|
|
|
| Below -100 °C: |
J, K, E, and N-types: ±[0.20% + 0.3°C]* |
|
T-type: ±[0.50% + 0.3°C] |
|
|
|
| Temperature |
| J-type: |
-210 °C to 1200 °C |
| K-type: |
-200 °C to 1372 °C |
| T-type: |
-250 °C to 400 °C |
| E-type: |
-150 °C to 1000 °C |
| N-type: |
-200 °C to 1300 °C * |
| R and S-type: |
0 °C to 1767 °C * |
|
| Temperature scale |
|
| Applicable standards |
|
| Display Resolution |
|
0.1 °C, 0.1 K < 1000 |
|
1°C, 1 K >=1000 |
|
| Note |
| * |
Only the Fluke Models 53 II B and 54 II B thermometers are capable of measuring N, R, and S-type thermocouples. |
|
| Environmental Specifications |
| Operating Temperature |
|
| Storage Temperature |
|
| Humidity (Without Condensation) |
|
0% to 90%; 0 °C to 35 °C |
|
0% to 70%; 0 °C to 50 °C |
|
| Safety Specifications |
| Overvoltage category |
|
CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 |
|
| Agency Approvals |
|
| Mechanical & General Specifications |
| Size |
|
173 mm L x 86 mm W x 38 mm |
|
| Weight |
|
| Batteries |
|
3 AA batteries; typical 1000-hour life |
|
|
| Model Name | Description | Price List | | Fluke 51 II |
Single Input Digital Thermometer including:
- Impact absorbing holster
- One 80PK-1 bead probe thermocouple
|
| On Request | | Fluke 52 II |
Dual Input Digital Thermometer including:
- Impact absorbing holster
- Two 80PK-1 beaded probe thermocouples
|
| On Request | | Fluke 53 II |
Single Input Digital Thermometer with data logging including:
- Impact absorbing holster
- One 80-PK-1 bead probe thermocouple
|
| On Request | | Fluke 54 II |
Dual Input Digital Thermometer including:
- Impact absorbing holster
- Two 80PK-1 bead probe thermocouples
|
| On Request |
| Cases and Holsters | Price List | | C101 | C101 Hard Case | On Request | | C50 | C50 Soft Meter Case | On Request | | C510 | C510 Leather Meter Case | On Request | | C550 | C550 Tool Bag | On Request | | CXT170 | CXT170 Extreme Case | On Request | | TPAK | TPAK ToolPak, Meter Hanging Kit | On Request |
| Software | Price List | | FlukeView Forms | FlukeView Forms Software with cable | On Request |
| Temperature | Price List | | 700TC2 | 700TC2 Thermocouple Plug Kits (5 types) | On Request | | 80CJ-M | 80CJ-M Male Mini Connectors (Type J) | On Request | | 80CK-M | 80CK-M Male Mini Connectors (Type K) | On Request | | 80PJ-EXT | 80PJ-EXT Extension Wire Kit (Type J) | On Request | | 80PK-1 | 80PK-1 Bead Probe (Type K) | On Request | | 80PK-22 | 80PK-22 Immersion Probe | On Request | | 80PK-24 | 80PK-24 Air Probe | On Request | | 80PK-25 | 80PK-25 Piercing Probe | On Request | | 80PK-26 | 80PK-26 General Purpose Probe | On Request | | 80PK-27 | 80PK-27 Industrial Surface Probe | On Request | | 80PK-3A | 80PK-3A Surface Probe (Type K) | On Request | | 80PK-8 | 80PK-8 Pipe Clamp Temperature Probe (Type K) | On Request | | 80PK-EXT | 80PK-EXT Extension Wire Kit (Type K) | On Request | | 80PT-EXT | 80PT-EXT Extension Wire Kit (Type T) | On Request |
|
|
|
|
|
|
|
|