The market’s best multimeters just got better
The 280 Series: designed for those who need the best
The Fluke 287/289 true-RMS digital multimeters were designed for those of you at the top of your field. The instruments replace our popular 180 Series, with all the same features, plus more.
The two multimeters perform advanced unattended data logging, and show trend data on screen without having to download to a PC. TrendCapture helps engineers and technicians track down problems faster during (for example) preventive and predictive maintenance.
An extra-large screen shows results graphically, backed by an enhanced user interface with on-board help (i-info key) available in seven languages, and soft-key interface. Both meters can log multiple sessions unattended in the field, with logged readings being reviewed without a PC. Both come with a lifetime warranty.
Key features of the Fluke 287/289:
- 0.025% DC accuracy, 100 kHz
- AC bandwidth
- Large 50,000 count, 1/4 VGA dot matrix display
- Data logging function with expanded memory
- TrendCapture allows you to graphically review logged readings right on the meter, without needing a PC. Store, up to 15,000 readings over time
- Advanced Min/Max/Average – all the data on one screen, with start and elapsed time
- "i" button – provides on-board function help
- Lifetime warranty
|
In addition, the Fluke 289 features:
- Two terminal 50 Ω range with 1 mΩ resolution, 10 mA
- Low Pass filter for accurate voltage and frequency measurements on adjustable speed motor drives
- LoZ Volts. Low impedance voltage function for eliminating ghost voltages
|
Click here for more detailed features of both the Fluke 287 and Fluke 289
The two Fluke instruments feature a large 50,000-count, 3-1/2 inch quarter-VGA dot matrix display that can show multiple measurement sets. The screen also features a white backlight with 2 positions, and displays context-sensitive on-board help screens. The instrument setup is customizable to save time and increase productivity. Multiple save options and automatic time stamping allow convenient recall of field measurements, while a PC interface ensures easy data transfer. Optional FlukeView® Forms PC software enables users to document, store and analyze readings, and then convert them into professional-looking reports.
Measure true-rms voltage and current
Fluke’s meters store up to 15,000 readings. For accurate measurement on non-linear signals, they can measure true-rms voltage and current. They have a 50 mF capacitance range, and measure up to 10 A (or 20 A for 30 seconds). Peak capture can record transients as fast as 250 microseconds. A relative mode removes test lead resistance from low ohms or capacitance measurements. Both meters have a battery life of 200 hours.
The Fluke 287/289 has an ac bandwidth of 100 kHz, and a 0.025% basic dc accuracy. It includes a temperature function.
Fluke multimeters are known for their ruggedness, life time warranty, safety ratings, product life time and low total cost of ownership.
The Fluke 287/289 meters withstand hazardous 8,000 V spikes caused by load switching and faults on industrial circuits, and complies with second edition IEC and ANSI electrical safety standards. It diagnoses problems in electronics, plant automation, power distribution and electromechanical equipment.
FlukeView® Forms Combo Kits
Both Fluke 287 and Fluke 289 come in a special FlukeView® Forms Combo Kit. These kits contain software with cable and several accessories.
Fluke 287/FVF Kit Fluke 289/FVF Kit
|
|
Key Features Include:
- Large 50,000 count, ¼ VGA display with white backlight. Multiple sets of measurement information can simultaneously be displayed at the same time.
- Logging function with TrendCapture is an essential tool for documenting the performance of your designs, processes or systems, or unattended monitoring while you work on other projects. It plots measurements as a single line to help detect signal anomalies over time, storing up to 10,000 readings. Using on-board TrendCapture, you can graphically view logged readings without a PC. (Software and interface cable optional).
- Log multiple sessions or log data continuously for over 200 hours.
- i-info button. On board help screens for measurement functions. Unsure about a function? Go to that function and Press the “i” button.
- Now, name your saved measurements and also recall measurements made in the field
- Real Time Clock – for automatic time stamping of saved readings
- Field upgradeable and expandable meter lets you stay current as new capabilities are added
- Multi-lingual interface
- Min/Max/Average with Time Stamp to record signal fluctuations
- Soft keys, scroll buttons and easy navigation control access to secondary functions.
- 0.025% Basic DC accuracy
- 100 kHz ac bandwidth
- True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads.
- Measure up to 10A (20 A for 30 seconds; 10A continuous)
- 100 mF capacitance range
- Temperature function
- Relative mode to remove test lead resistance from low ohms or capacitance measurements
- Peak capture to record transients as fast as 250 μs
- Premium test leads and alligator clips included
- Optional FlukeView forms enables you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents
- Optional magnetic hanger allows you to hang the meter for easy viewing while freeing your hands to focus on the job.
- Limited lifetime warranty
- CAT III 1000 V / CAT IV 600 V safety rated
|
In addition, the Fluke 289 features:
- LoZ Volts. Low impedance voltage function prevents false readings due to “ghost voltage.” It is also the recommended mode when testing for absence or presence of live power.
- Low Pass Filter for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment.
- 50 ohm range – useful for measuring and comparing differences in motor winding resistance, low ohm measurements, or other contact resistance. Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current.
- Saved measurements allow you to name and recall measurements made in the field
- Optical USB PC communication interface allows for easy PC download to document logged data with FVF software (not included).
|
|
|
| Specifications |
| Voltage DC |
| Accuracy |
0.025 % |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
| | Voltage AC |
| Accuracy |
0.4 %(true-rms) |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
| | Current DC |
| Accuracy |
0.06 % |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| | Current AC |
| Accuracy |
0.61 %(true-rms) |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| | Temperature (excluding probe) |
| Accuracy |
1.0 % |
| Range and Resolution |
-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) |
| | Resistance |
| Accuracy |
0.05 % |
| Range and Resolution |
500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
| | Resistance 10 50 Ω (2 wire connection) |
| Accuracy |
0.15 % + 20 |
| Range and resolution |
50.000 Ω |
| | Capacitance |
| Accuracy |
1.0 % |
| Range and Resolution |
1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF,
100.00 mF Ω |
| | Frequency |
| Accuracy |
0.005% + 5 |
| Range and Resolution |
99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
| | Additional functions/features |
| Multiple on-screen displays |
Yes |
| True-rms AC bandwidth |
100 kHz |
| DBV/dBm |
Yes |
| DC mV resolution |
1 μV |
| Megohm range |
Up to 500 M |
| Conductance |
50.00nS |
| Continuity beeper |
Yes |
| Battery/Fuse access |
Battery / Fuse |
| Peak |
250 μS |
| Elapse time clock |
Yes |
| Time of day clock |
Yes |
| Min-Max-Avg |
Yes |
| Frequency |
Yes |
| Duty Cycle |
0.01 % to 99.99 % |
| Pulse Width |
0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms |
| Hold |
Yes |
| Isolated Optical Interface |
Yes |
| Auto/Touch Hold |
Yes |
| Reading memory |
Yes |
| Log to PC |
Yes |
| Interval/Event Logging |
Yes |
| Logging Memory |
Up to 10,000 readings |
| Resistance Low Ohm |
0.001 Ω to 50.000 Ω 10 mA source |
| LoZ |
Yes |
| Low Pass Filter |
Yes |
|
| Environmental Specifications |
| Operating Temperature | | | Storage Temperature | | | Relative Humidity |
|
0% to 90% (0 °C - 37 °C) |
|
0% to 65% (37 °C - 45 °C), |
|
0 to 45 % (45 °C - 55 °C |
| | Electromagnetic Compatability | | | Vibration |
|
Random vibration per MIL-PRF-28800f Class 2 |
| | Shock |
|
1 meter drop per IEC/EN 61010-1 2nd edition |
|
| Safety Specifications |
| Overvoltage category |
|
CAT III 1000 V / CAT IV 600 V safety rated |
| | Agency Approvals | |
| Mechanical & General Specifications |
| Maximum voltage between any terminal and earth ground | | | Size |
|
(HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in) |
| | Weight | | | Battery Life |
|
100 minimum, 200 hours in logging mode |
| | Battery type |
|
6 AA alkaline batteries, NEDA 15A IEC LR6 |
|
|
| Model Name | Description | Price List | | Fluke 287 | True-rms Electronics Logging Multimeter with TrendCapture
All models include:
- Manual
- 6 AA Batteries, installed
- TL71 Silicone Test Leads
- Probe Holder
- Two AC175 Alligator Clips
|
| On Request | | Fluke 289 | True-rms Electronics Logging Multimeter with TrendCapture
| On Request |
| Clips | Price List | | AC220 | AC220 SureGrip™ Alligator Clip Set | On Request | | AC280 | AC280 SureGrip™ Hook Clips | On Request | | AC283 | AC283 SureGrip™ Pincer Clips | On Request | | AC285 | AC285 SureGrip™ Alligator Clip Set | On Request | | AC89 | AC89 Heavy Duty Insulation Piercing Test Clip | On Request | | TLK225 | TLK225 SureGrip™ Master Accessory Kit | On Request |
| Test Probes | Price List | | TL910 | TL910 Electronic Test Probes | On Request | | TP2 | TP2 Slim Reach Test Probe (2 mm) | On Request | | TP220 | TP220 SureGrip™ Industrial Test Probes | On Request | | TP38 | TP38 Slim Reach Test Probe (insulated) | On Request | | TP4 | TP4 Slim Reach Test Probe (4 mm) | On Request | | TP74 | TP74 Lantern Tip Test Probes | On Request | | TP80 | TP80 Electronic Test Probes | On Request | | TP912 | TP912 Replacement Tips for TL910 | On Request | | TP920 | TP920 Test Probe Adapter Kit | On Request |
| Batteries, Chargers and Adapters | Price List | | IR189USB | IR189USB USB Cable adapter | On Request |
| Cases and Holsters | Price List | | C101 | C101 Hard Case | On Request | | C116 | C116 Soft Carrying Case | On Request | | C1600 | C1600 Gear Box for Meter and Accessories
| On Request | | C280 | C280 Soft Case | On Request | | C550 | C550 Tool Bag | On Request | | C781 | C781 Meter Case | On Request | | CXT280 | CXT280 Extreme Case | On Request | | CXT80 | CXT80 Extreme Case | On Request | | TPAK | TPAK ToolPak, Meter Hanging Kit | On Request |
| Current clamps | Price List | | i1010 | i1010 AC/DC Current Clamp | On Request | | i200 | i200 AC Current Clamp | On Request | | i2000 flex | i2000 flex AC Current Clamp | On Request | | i400 | i400 AC Current Clamp | On Request | | i410 | i410 AC/DC Current Clamp | On Request |
| Fiber Optics | Price List | | FOM Fiber Optic Meter
| FOM Fiber Optic Meter | On Request |
| High Voltage Probes | Price List | | 80K-40 | 80K-40 High Voltage Probe | On Request | | 80K-6 | 80K-6 High Voltage Probe | On Request |
| Lights | Price List | | L200 | L200 Probe Light | On Request | | L210 | L210 Probe Light + Probe Extender | On Request | | L215 | L215 SureGrip™ Kit with Probe Light and Probe Extender | On Request | | LVD1 | LVD1 Volt Light | On Request |
| Test Leads, Probes and Clips | Price List | | TL80A | TL80A Basic Electronic Test Lead Set | On Request |
| Pressure | Price List | | PV350 | PV350 Pressure Vacuum Module | On Request |
| Temperature | Price List | | 80AK-A | 80AK-A Thermocouple Adapter | On Request | | 80BK-A | 80BK-A Integrated DMM Temperature Probe | On Request | | 80PK-1 | 80PK-1 Bead Probe (Type K) | On Request | | 80PK-26 | 80PK-26 General Purpose Probe | On Request | | 80PK-EXT | 80PK-EXT Extension Wire Kit (Type K) | On Request | | 80T-150UA | 80T-150U Universal Temperature Probe (for DMMs) | On Request | | 80TK | 80TK Thermocouple Module (Type K) | On Request |
| Test Leads | Price List | | H900 | H900 Test Lead Holder | On Request | | TL220 | TL220 SureGrip™ Industrial Test Lead Kit | On Request | | TL221 | TL221 SureGrip™ Extension Lead Set | On Request | | TL223 | TL223 SureGrip™ Electrical Test Lead Kit | On Request | | TL224 | TL224 SureGrip™ Silicone Test Lead Set | On Request | | TL225 | TL225 SureGrip™ Stray Voltage Adapter Test Lead Kit | On Request | | TL238 | TL238 SureGrip™ Test Lead Set for High Energy Environments | On Request | | TL28A | TL28A Automotive Test Lead Set | On Request | | TL40 | TL40 Retractable Tip Test Lead Set | On Request | | TL71 | TL71 Test Lead Set | On Request | | TL75 | TL75 Hard Point Test Lead Set | On Request | | TL76 | TL76 All-in-one Test Lead Set | On Request | | TL80A | TL80A Basic Electronic DMM Test Set | On Request | | TL81A | TL81A Deluxe Electronic Test Lead Set | On Request | | TL930 | TL930 Patch Cord Set (60 cm) | On Request | | TL932 | TL932 Patch Cord Set (90 cm) | On Request | | TL935 | TL935 Patch Cord Kit (60, 90, 120 cm) | On Request | | TL940 | TL940 Mini-Hook Test Lead Set | On Request | | TL950 | TL950 Mini-Pincer Test Lead Set | On Request | | TL960 | TL960 Micro-Hook Test Lead Set | On Request | | TL970 | TL970 Hook and Pincer Kit | On Request | | TLK287 | TLK287 Electronics Master Test Lead Set | On Request | | TLK289 | TLK289 - Industrial Master Test Lead Set | On Request |
|
|
|
|
|
|
 | | Search Fluke | | | | | | | | | | | | | | | | | | | | | | | | Find Resources | | | | | | | | |
|
|
|
|
|
|
|
|
|
|
|
| | |