i50S, AC Scope Current Probe, 50 MHz

 i50S
Designed for use with bench oscilloscopes, the i50s Current Probe offers an ergonomic, robust and high performing solution for the measurement of DC and AC currents up to 50 MHz. With a permanent nominal current of 30 A RMS and a measuring capacity of 50 A for 10 s, as well as exceptional immunity to high common mode voltages (dv/dt = 5 kV/_s,) amplitude = 1,5 kV, error < 0,05 % of IPN), the i50s considerably widens the possibilities of accurate measurement of commutation currents.
  • Bandwidth DC up to 50 MHz
  • Nominal current 30 A
  • Max. current 50 A, < 10 s
  • Automatic zero adjustment and degauss functions
  • Overheating and Head Unlocked warning
  • Rise time < 7 ns
  • External magnetic field rejection rate AC and DC 60 dB
  • Rejection rate of fast dv/dt (5kV/_s) < 15 mA t
Electrical Characteristics
Nominal current (In)
 ± 30 A dc or A rms
Measuring range (duration <10 sec)
 I max ±50 A pk
Output Sensitivity
 low range 1 V/A (1 MΩ)
 High range 100 mV/A (1 MΩ)
Overall accuracy (dc to 100 Hz at 25 °C)
 ± 0.5 % at In typical
 ± 1.5 % at I max
Gain variation (max)
 ± 0.04 % of rdg/ °C
Step response
 in Data Sheet
Frequency response
 in Data Sheet
Insertion impedance (ZI)
 in Data Sheet
 < 0.1 Ω up to 10 MHz
 < 0.4 Ω 10 MHz to 50 MHz
External magnetic field rejection rate
 60 dB (ac and dc)
Rejection rate of fast dV/dt at 5 kV/ μs
 < 15 m At (during dV/dt)
Output noise level (measured with a filter at 25 MHz)
 1 m At rms typical
Output noise level (measured with a filter at 25 MHz)
 9 mA tpp

Dynamic Characteristics
Bandwidth
 DC to 50MHz(-3dB)
Frequency derating (see Figure 4)
 10 A at 10MHz
Rise time, (10 % to 90 %)
 tr < 7ns
Delay time
 td < 25 ns
Overshoot
 < 5 % of reading

General Characteristics
Aperture dimensions
 5 x 5 mm (0.2 in x 0.2 in)
Max primary conductor temp
 60 ° C (140 °F)
Dielectric withstand
 1350 Vrms / 50 Hz / 1 min
Working Voltage
 300 Vrms or DC (CAT I)
 150 Vrms or DC (CAT II)
Operating temperature
 °C to + 40 °C (32 °F to 104 °F)
Storage temperature
 -10 °C to + 60 °C (14 °F to 140 °F)
Maximum Altitude
 2000 m (6600 ft)
Maximum relative humidity
 80 % , 31 °C (87 °F)
Environment
 indoor use only
Power supply
 ± 12 V ± 0.5 V
Current consumption at nominal
 30 A 550 mA
Current consumption during demagnetization
 1.3 A (for 6 sec) Probe
Output cable length
 2 m (6.6 ft)
Model NameDescriptionPrice List
i50s AC/DC SCOPE CURRENT PROBE,50MHZ
Included:

  • Carrying case
  • Power supply cable
  • Calibration certificate
  • Power supply adapter
  • Earthing lead
  • Operators manual