Specified current range
 30 mA to 30A dc, 30 mA to 20 A ac rms
Usable current range
 5 mA to 30 A dc, 30 mA to 20 A ac rms
Crest Factor
 1.4"
Output sensitivity
 100 mV/A
Accuracy (at +25 °C)
 ± 1 % of reading ± 2 mA
Resolution
 ± 1 mA
Load impedance
 > 100 kΩ
Conductor position sensitivity
 ± 1 % relative to center reading
Frequency range
 DC to 100 kHz (- 0.5 dB)
Phase shift below 1 kHz
 < 2 degrees
Temperature coefficient
 ± 0.01 % of reading/°C
Power supply
 9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Working voltage (see Safety Standards section)
 300 V ac rms or dc

General specifications
Maximum conductor size
 19 mm diameter
Output connection
 Safety BNC connector, supplied with safety 4 mm adapter
Output zero
 Manual adjust via thumbwheel
Cable length
 2 meters
Operating temperature range
 0 °C to +50 °C
Storage temperature range (with battery removed)
 -20 °C to +85 °C
Operating humidity
 15 % to 85 % (non-condensing)
Weight
 250 g
Safety standards
 BS EN 61010-1: 2001
 BS EN 61010-2-032: 2002
 BS EN 61010-031: 2002
 300 Vrms, Category III, Pollution Degree 2
 Use of the probe on uninsulated conductors is limited to 300 V acrms or dc and frequencies below 1 kHz.