A Fluke thermal imager can save you time and money by finding potential problems before they become costly failures. With the innovative features and functionality in the Fluke Ti125 Thermal Imager and its 160 x 120 resolution, you can perform infrared inspections faster and more efficiently while thoroughly documenting problem areas for additional follow-up.
|
- Exclusive IR-OptiFlex™ focus system—ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger.
- Always have references handy—IR-PhotoNotes™ annotation system—Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas.
- Find problems faster and easier—IR-Fusion® with AutoBlend™ mode—Accurately identify potential issues by combining digital and IR images with AutoBlend. It blends digital and partially transparent IR images into a single information-filled image.
- Multi-mode video recording—focus-free video in visible light and infrared with full IR-Fusion.
- Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal).
Spend less time finding problems and more time solving them with the innovative, rugged and easy to use Ti125 Industrial-Commercial Thermal Imager.
|
| Detailed Specifications |
| IR resolution (FPA size) |
160 x 120 FPA Uncooled Microbolometer |
| Spectral band |
7.5 μm to 14 μm (long wave) |
| Capture or refresh rate |
9 Hz or 30 Hz versions |
| NETD (Thermal sensitivity) |
≤ 0.10 °C at 30 °C target temp (100 mK)
0.10 °C at 30 °C target temp (100 mK) |
| FOV (Field of view) |
22.5 °H x 31 °V |
| IFOV (Spatial resolution) |
3.39 mRad |
| Temperature measurement range (not calibrated below -10 °C) |
-20 °C to +350 °C (-4 °F to +662 °F) |
| Temperature measurement accuracy |
± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
| Focus mechanism |
IR-OptiFlex™ focus system |
| IR-Fusion® technology |
PIP, FULL IR, FULL VISIBLE, AutoBlend™ |
| Color alarms |
High temperature, low temperature, isotherm |
| Standard palettes |
Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber |
| Ultra Contrast™ palettes |
Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber |
| Hot/cold markers |
Yes |
| User definable spot markers |
Three on camera and in SmartView® |
| Centerbox (MIN/AVG/MAX) |
Yes |
| Level and span control |
Manual and auto |
| Minimum span in auto mode |
5 °C |
| Minimum span in manual mode |
2.5 °C |
| Minimum IR focus distance |
15.25 cm (6 in) |
| Weight |
0.726 kg (1.6 lb) |
| Size |
28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) |
| LCD display |
3.5 inch diagonal (portrait format) |
| Visible camera |
2 megapixel industrial-grade |
| Minimum automatic parallax correction |
~18-22 inches |
| IR-PhotoNotes™ annotation system |
Yes (3 images) |
| Laser pointer |
Yes |
| Torch |
Yes |
| Electronic (cardinal) compass |
Yes |
| Emissivity correction |
Yes |
| Transmission correction |
Yes |
| Background (reflected) compensation |
Yes |
| Voice annotation (audio) |
Yes (60 seconds) per image |
| Multi-mode video output |
Streaming USB video output (infrared, visible and IR-Fusion modes) |
| Multi-mode video recording (standard avi w/ mpeg encoding) |
Yes (AVI with MPEG encoding, up to 5 minutes) |
| Multi-mode video recording (radiometric .Is3) |
Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene |
| Memory review |
thumbnail review |
| Battery (field-replaceable, rechargeable) |
Two |
| Battery life |
4+ hours (each)* |
| External battery charging base |
Yes |
| Charging power supply |
Yes |
| Drop test |
2 meter (6.5 feet) |
| Ingress protection (IP) rating (IEC 60529) |
IP 54 |
| Recommended Calibration cycle |
Two-years |
| Multifunction card reader |
Included |
| Memory storage |
2 GB SD memory card |
| Direct download capability |
mini USB download direct to PC |
| Operating temperature range |
-10 °C to +50 °C (14 °F to 122 °F) |
| Storage temperature range |
-20 °C to +50 °C (-4 °F to 122 °F) |
| Operating humidity |
Operating and storage 10 % to 95 %, Non-condensing |
| Vibration and shock |
2G, IEC 68-2-26 and 25G, IEC 68-2-29 |
| Safety standards |
CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 |
| C Tick |
IEC/EN 61326-1 |
| EMI, RFI, EMC |
EN61326-1; FCC Part 5 |
| User manuals |
Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian |
| Standard warranty period |
Two-years |
| Extended warranty and service plans |
Yes |
*Assumes 50% brightness of LCD
|
| Model Name | Description | Price List | | FLK-Ti125 9 Hz | Industrial-Commercial Thermal Imager (9 Hz)
Includes:
- Thermal imager
- AC power adapter
- Lithium ion smart battery (2)
- USB cable
- SD memory card
- Hard carrying case
- Soft transport bag
- Adjustable hand strap (left- or right-handed use)
- Printed users’ manual in English, Spanish, French, German and Simplified Chinese, all other manuals on CD—total of 18
- SmartView® software and warranty registration card
- Two-bay charging base
- Multi-format USB memory card reader
| On Request |
| Thermal Imaging Accessories | Price List | | Tripod Mounting Accessory for Ti125, Ti110, Ti100, TiR125 and TiR110 Thermal Imagers. | On Request | | Sun Visor for Ti125, Ti110, Ti100, TiR125 and TiR110 Thermal Imagers. | On Request | | Introduction to Thermography Principles | On Request |
| Batteries, Chargers and Adapters | Price List | | Extra battery pack for Ti32, Ti29, Ti27, Ti125, Ti110, Ti100, TiR32, TiR29, TiR27, TiR125 and TiR110 Thermal Imagers. | On Request | | TI-CAR CHARGER | On Request |
|
|
|
|
|
|
|
|