“A complete documenting calibrator”

The 741B does the work of several tools – sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. For documentation, the 741B automates calibration procedures and captures your data.
And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.
The 741B is the choice for plants that use standard company worksheets and that make reports in the shop. It has storage capacity for a day's calibration and measurement data. When you're back at the shop recall the data on screen to fill out calibration forms.


The 741B is easy to use with flexible test strategies. And like all Fluke tools, it's rugged, reliable and tough as nails. It's like having several powerful tools in one - so you can work faster than ever:
  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Measure and source simultaneously with one compact, rugged, reliable tool
  • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
  • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
  • Easy to use
  • Three year warranty
  • Bright white display. Read both sourced and measured parameters.
  • Multi lingual interface
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1msec.
Measurement Accuracy
Voltage DC
110.000 mV  0.025%+0.015% *
1.10000 V  0.025%+0.005% *
11.0000 V  0.025%+0.005% *
110.000 V  0.05%+0.005% *
300.00 V  0.05%+0.005% *
Voltage AC
20 to 40 Hz  2% + 10
40 to 500 Hz  0.5% + 5
500 to 1 kHz  2% + 10
1 kHz to 5 kHz  10% + 20
Ranges:  1.1000, 11.000, 110.00, 300V
Current DC
30.000 mA  0.01% + 0.015% *
110.00 mA  0.01% + 0.015% *
Resistance
11.000 Ω  0.05% + 50 mΩ
110.00 Ω  0.05% + 50 mΩ
1.1000 kΩ  0.05% + 500 mΩ
11.000 kΩ  0.1% + 10 Ω
Frequency
1.00 to 109.99 Hz  0.05 Hz
110.0 to 1099.9 Hz  0.5 Hz
1.100 to 10.999 kHz  5 Hz
11.00 to 50.00 kHz  50 Hz
Pressure
Accuracy  from 0.025% of range using any of 29 pressure modules.
 (for detailed specifications refer to pressure modules in options and accessories)
 Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Note
*  (% of reading + % of full scale)

Source Accuracy
Voltage DC
110.000 mV  0.01%+0.005% *
1.10000 V  0.01%+0.005% *
15.0000 V  0.01%+0.005% *
Current DC
22.000 mA (Source)  0.01%+ 0.015% *
22.000 mA (Simulate)  0.02% + 0.03% *
Resistance
11.000 Ω  0.01% + 20 mΩ
110.00 Ω  0.01% + 40 mΩ
1.1000 kΩ  0.02% + 500 mΩ
11.000 kΩ  0.03% + 5Ω
Frequency
0.00 to 10.99 Hz  0.01 Hz
11.00 to 109.99 Hz  0.1 Hz
110.0 to 1099.9 Hz  0.1 Hz
1100 to 21999 Hz  2 Hz
22.000 to 50.000 kHz  5 Hz
Note
*  (% of reading + % of full scale)

RTDs and Thermocouples
Measure Accuracy:
10 Ω Cu (427):  2 °C
100 Ω Pt (3916):  0.3 °C
100 Ω Pt (3926):  0.3 °C
100 Ω Pt (385):  0.3 °C
200 Ω Pt (385):  0.3 °C
500 Ω Pt (385):  0.3 °C
1000 Ω Pt (385):  0.3 °C
120 Ω Ni (672):  0.3 °C
note:  For 2-and 3-wire measurement, add 0.4 °C
E:  0.3 °C
N:  0.5 °C
J:  0.3 °C
L:  0.3 °C
K:  0.3 °C
T:  0.3 °C
U:  0.3 °C
B:  0.9 °C
R:  1.0 °C
S:  0.9 °C
C:  0.6 °C
note:  Accuracy with external cold junction, for internal junction add 0.2°C
Source Accuracy:
10 Ω Cu (427):  1 °C
100 Ω Pt (3916):  0.1 °C
100 Ω Pt (3926):  0.1 °C
100 Ω Pt (385):  0.1 °C
200 Ω Pt (385):  0.1 °C
500 Ω Pt (385):  0.1 °C
1000 Ω Pt (385):  0.1 °C
120 Ω Ni (672):  0.1 °C
note:  For 2-and 3-wire simulation, add 0.4 °C
E:  0.2 °C
N:  0.3 °C
J:  0.2 °C
L:  0.2 °C
K:  0.3 °C
T:  0.3 °C
U:  0.3 °C
B:  0.8 °C
R:  0.9 °C
S:  0.9 °C
C:  0.6 °C
note:  Accuracy with external cold junction, for internal junction add 0.2 °C

Specifications
Ramp Functions
Source functions:  Voltage, current, resistance, frequency, temperature
Rate:  4 steps/second
Trip detect:  Continuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
Voltage:  Selectable, 24 V or 28 V
Accuracy:  5%
Maximum current:  22 mA, short circuit protected
Maximum input voltage:  30 V DC
Step Functions
Source Functions  Voltage, current, resistance, frequency, temperature
Manual Step  Selectable step, change with arrow buttons
Autostep  Fully programmable for function, start delay, stepvalue, time per step, repeat

Environmental Specifications
Operating Temperature
 -10 °C to +50 °C
 -20 °C to +50 °C *
Storage Temperature
 -20 °C to +60 °C
Dust/water resistance
 Meets IP52, IEC 529
Operating Altitude
 2800 m
Note
*  Except frequency and AC

Safety Specifications
Agency Approvals
 CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993

Mechanical & General Specifications
Size
 130 x 236 x 61 mm
Weight
 1.4 kg
Batteries
NiCd:  7.2V, 1.7 Ah
Battery Life
 ~8 hours typical
Battery Replacement
 Via snap-shut door without opening calibrator; no tools required
Side port connections
 Pressure module connector
 Connection for optional battery eliminator
Data storage capacity
 1 day of calibration results
90 day specifications
 The standard specification intervals for the 741B is 1 and 2 years.
 Typical 90 day measurement and source accuracy can be estimated by
  dividing the one year "% of reading" or "%of output" specifications by 2.
 Floor specifications, expressed as "% of full scale" or
  "counts" or "ohms" remain constant.
Model NameDescriptionPrice List
Fluke 741B Documenting Process Calibrator
  • BC7217 battery charger
  • BP7217 battery pack
  • Instruction manual
  • NIST-traceable calibration report and data
  • One set of TP220 test probes
  • Two sets of AC220 test clips
  • Two sets of TL224 industrial test leads
On Request

ClipsPrice List
AC220AC220 SureGrip™ Alligator Clip SetOn Request
AC280AC280 SureGrip™ Hook ClipsOn Request
AC283AC283 SureGrip™ Pincer ClipsOn Request
AC285AC285 SureGrip™ Alligator Clip SetOn Request

Test ProbesPrice List
TP920TP920 Test Probe Adapter KitOn Request

Differential Pressure ModulesPrice List
700P00700P00 Differential Pressure Module (2.5 mbar)On Request
700P01700P01 Differential Pressure ModuleOn Request
700P02700P02 Differential Pressure Module (70 mbar)On Request
700P03700P03 Differential Pressure Module (340 mbar)On Request
700P04700P04 Differential Pressure Module (1000 mbar)On Request

Differential Pressure Module WetPrice List
700P22700P22 Differential Pressure Module Wet (70 mbar)On Request
700P23700P23 Differential Pressure Module Wet (340 mbar)On Request
700P24700P24 Differential Pressure Module WetOn Request

Absolute Pressure ModulesPrice List
700PA3700PA3 Absolute Pressure Module (340 mbar)On Request
700PA4700PA4 Absolute Pressure ModuleOn Request
700PA5700PA5 Absolute Pressure Module (2 bar)On Request
700PA6700PA6 Absolute Pressure Module (7 bar)On Request
700PRV-1700PRV Pressure Relief Valve KitOn Request

Batteries, Chargers and AdaptersPrice List
BC7217BC7217 Battery ChargerOn Request
BP7235BP7235 NiMH Battery PackOn Request

Cases and HolstersPrice List
C125C125 Soft Meter Case On Request
C550C550 Tool BagOn Request
C700C700 Hard Case (700 Series)On Request
C75C75 Accessory CaseOn Request
C781C781 Meter CaseOn Request
C789C789 Soft Meter CaseOn Request

ConnectorsPrice List
700BCA700BCA Bar Code AdapterOn Request
700BCW700BCW Bar Code WandOn Request

Current clampsPrice List
i200i200 AC Current ClampOn Request
i200si200s AC Current ClampOn Request

Dual Pressure ModulesPrice List
700PD2700PD2 Dual Pressure Module (± 70 mbar)On Request
700PD3700PD3 Dual Pressure Module (± 340 mbar)On Request
700PD4700PD4 Dual Pressure Module (±1000 mbar)On Request
700PD5700PD5 Dual Pressure Module (-1000/+2000 mbar)On Request
700PD6700PD6 Dual Pressure Module (-1000 mbar/+6.9 bar)On Request
700PD7700PD7 Dual Pressure Module ( -1000 mbar/+13.8 bar) On Request

SoftwarePrice List
750SWFluke 750 SW DPC/TRACK2 SoftwareOn Request

Vacuum Pressure ModulesPrice List
700PV3700PV3 Vacuum Pressure Module (-340 mbar)On Request
700PV4700PV4 Vacuum Pressure Module( -1000 mbar)On Request

TemperaturePrice List
700TC2700TC2 Thermocouple Plug Kits (5 types)On Request
80CJ-M80CJ-M Male Mini Connectors (Type J)On Request
80CK-M80CK-M Male Mini Connectors (Type K)On Request
80PJ-EXT80PJ-EXT Extension Wire Kit (Type J)On Request
80PK-180PK-1 Bead Probe (Type K) On Request
80PK-2280PK-22 Immersion Probe On Request
80PK-2480PK-24 Air Probe On Request
80PK-2580PK-25 Piercing Probe On Request
80PK-2680PK-26 General Purpose ProbeOn Request
80PK-2780PK-27 Industrial Surface ProbeOn Request
80PK-880PK-8 Pipe Clamp Temperature Probe (Type K)On Request
80PK-980PK-9 General Purpose Probe (Type K)On Request
80PK-EXT80PK-EXT Extension Wire Kit (Type K)On Request
80PT-2580PT-25 SureGrip Piercing Temperature ProbeOn Request

Test LeadsPrice List
TL940TL940 Mini-Hook Test Lead SetOn Request
TL950TL950 Mini-Pincer Test Lead SetOn Request
Search Fluke
ResourcesProducts
Find Resources

Home | Site Map | Fluke Corporation  | Terms and Conditions | Privacy Statement | Disclaimer© 1995 - 2013 Fluke Corporation