Middle East [Change]  |  Fluke [Change Company]
fluke
Home  |  Products  |  Process Calibration Tools  |  Loop Calibrators  |  
Contact usRefer this page

Fluke 707 Loop Calibrator

Contact Me
Request A Demo
 Fluke 707
The fastest, one-handed tool for loop checks.

The Fluke 707 Loop Calibrator is a high performance solution for calibration, repair and maintenance of current loops. The new "Quick Click" knob making it extremely fast and easy to use. It features:

  • One handed user interface with "Quick Click" detented knob
  • mA sourcing, simulation and measurement
  • 0.015% accuracy and 0.001 mA resolution
  • Simultaneous mA and % of span display
  • Selectable step or ramp outputs
  • 24 V Loop supply with mA measure, including 250Ω HART resistor
  • 0-28 VDC measurement to check Loop Voltage
  • Easy battery exchange without opening the case
  • Compact case with separate protective holster
  • Three year warranty
The fast, one-handed tool for loop checks. Just click to calibrate.
This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:
  • Large display and simple, quick-click interface for easy one-handed operation.
  • Simultaneous mA and % readout for quick, easy interpretation of readings.
  • mA accuracy of 0.015%, superior to other loop calibrators in this price range.
  • 1 µA resolution for mA source, simulate and measure.
  • Push button 25% steps for fast, easy linearity checks.
  • 0-100% “span check” for fast confirmation of zero and span.
  • Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
  • 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
  • Measures V dc to 28 V.
  • Single 9V battery that is easily changed without braking calibration seal
  • 0 - 20 mA or 4 - 20 mA default start up modes.
  • Innovative output adjustment dial with 1 µA and 100 resolution.
  • HART ™ mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.

Safety conformance

CSA C22.2 No. 1010.1:1992

Specifications
Current Measurement
Range:  0 to 24 mA
Resolution:  0.001 mA
Accuracy:  0.015% Rdg + 2 LSD
Current Sourcing
Range:  0 to 20 mA or 4 to 20 mA
Accuracy:  0.015% Rdg + 2 LSD
Drive Capability:  1200 Ω; 950 Ω at 20 mA in HART mode
Current Simulation
Range:  0 to 20 mA or 4 to 20 mA
Accuracy:  0.015% Rdg + 2 LSD
Ext. loop voltage requirement:  12-30 V
Loop Power
 While measuring mA, 24 V
Voltage measurement
Range:  0 to 28 V DC
Resolution:  1 mV
Accuracy:  0.015% Rdg + 2 LSD

Environmental Specifications
Operating Temperature
 -10ºC to 55ºC
Storage Temperature
 -30ºC to 60ºC
Humidity (Without Condensation)
 0 to 90% (0ºC to 35ºC); 0 to 70% (35ºC to 55ºC)
Temperature Coefficient
 -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC

Safety Specifications
Safety
 CSA C22.2 No. 1010.1:1992
EMC
 EN50082-1:1992 and EN55022:1994 Class B
Maximum voltage
 30V

Mechanical & General Specifications
Size
 152 x 70 x 41 mm
Weight
 224 g (340 g including holster)
Batteries
 One 9V battery Alkaline
Warranty
 Three years
Shock & Vibration
 per MIL-T-28800 for a Class 2 Instrument
Display current and % of span
 Yes
Auto step, auto ramp
 Yes
Span Check
 Yes
Model NameDescriptionPrice List
Fluke 707 Loop Calibrator including:
  • AC70A Alligator Clips
  • C10 protective yellow holster with Flex-Stand™
  • Instruction sheet
  • TL75 safety-designed test lead set
  • NIST- traceable calibration report and data
On Request

Cases and HolstersPrice List
C10C10 Meter HolsterOn Request

ClipsPrice List
AC220AC220 SureGrip™ Alligator Clip SetOn Request
AC280AC280 SureGrip™ Hook ClipsOn Request
AC283AC283 SureGrip™ Pincer ClipsOn Request
AC285AC285 SureGrip™ Alligator Clip SetOn Request
AC87AC87 Heavy Duty Bus Bar Clip SetOn Request
AC89AC89 Heavy Duty Insulation Piercing Test ClipOn Request
BP980BP980 Double Banana Plug KitOn Request

Test ProbesPrice List
TL910TL910 Electronic Test ProbesOn Request
TP1TP1 Slim Reach Test Probe (flat blade)On Request
TP2TP2 Slim Reach Test Probe (2 mm)On Request
TP220TP220 SureGrip™ Industrial Test ProbesOn Request
TP38TP38 Slim Reach Test Probe (insulated)On Request
TP4TP4 Slim Reach Test Probe (4 mm)On Request
TP74TP74 Lantern Tip Test ProbesOn Request
TP80TP80 Electronic Test ProbesOn Request
TP912TP912 Replacement Tips for TL910On Request
TP920TP920 Test Probe Adapter KitOn Request

Cases and HolstersPrice List
C100C100 Hard Meter and Accessory CaseOn Request
C12AC12A Soft Meter CaseOn Request
C195C195 Soft Case On Request
C25C25 Soft Meter CaseOn Request
C800C800 Hard Meter and Accessory CaseOn Request

Test Leads, Probes and ClipsPrice List
TL80ATL80A Basic Electronic Test Lead SetOn Request

PressurePrice List
PV350PV350 Pressure Vacuum ModuleOn Request

TemperaturePrice List
80T-150UA80T-150U Universal Temperature Probe (for DMMs)On Request
80TK80TK Thermocouple Module (Type K)On Request

Test LeadsPrice List
H900H900 Test Lead HolderOn Request
TL27TL27 Heavy Duty Test Lead SetOn Request
TL220TL220 SureGrip™ Industrial Test Lead KitOn Request
TL221TL221 SureGrip™ Extension Lead SetOn Request
TL222TL222 SureGrip™ Silicone Test Lead SetOn Request
TL223TL223 SureGrip™ Electrical Test Lead KitOn Request
TL224TL224 SureGrip™ Silicone Test Lead SetOn Request
TL238TL238 SureGrip™ Test Lead Set for High Energy EnvironmentsOn Request
TL40TL40 Retractable Tip Test Lead SetOn Request
TL71TL71 Test Lead SetOn Request
TL75TL75 Hard Point Test Lead SetOn Request
TL76TL76 All-in-one Test Lead SetOn Request
TL81ATL81A Deluxe Electronic Test Lead SetOn Request
TL930TL930 Patch Cord Set (60 cm)On Request
TL932TL932 Patch Cord Set (90 cm)On Request
TL935TL935 Patch Cord Kit (60, 90, 120 cm)On Request
TL940TL940 Mini-Hook Test Lead SetOn Request
TL950TL950 Mini-Pincer Test Lead SetOn Request
TL960TL960 Micro-Hook Test Lead SetOn Request
TL970TL970 Hook and Pincer KitOn Request
Search Fluke
ResourcesProducts
Find Resources

Home | Site Map | Fluke Corporation  | Terms and Conditions | Privacy Statement | Disclaimer© 1995 - 2013 Fluke Corporation