Middle East [Change]  |  Fluke [Change Company]
fluke
Home  |  Products  |  Industrial Calibrators  |  
Contact usRefer this page

Fluke Calibration 9102 Handheld Dry-Well

9102 Handheld Dry-Well

World’s smallest, lightest and most portable dry-wells

  • Smallest dry-wells in the world
  • Ranges from –10°C to 375°C
  • Accuracy to ±0.25°C, stability of ±0.05°C at 0°C
  • RS-232 interface with 9930 Interface-it v3.81 software
  • Hart’s line of portable dry-wells is incredible. They’re the smallest, lightest, and most portable dry-wells in the world. And now they're better than ever!

    9100S Dry-Well
    Since we introduced the world’s first truly handheld dry-well, many have tried to duplicate it—in vain. Despite its small size (2¼ inches high and 5 inches wide) and light weight, the 9100S outperforms every dry-well in its class in the world.

    It’s simple and convenient, too. Anyone can learn to use one in less than 15 minutes. It has a range to 375°C (707°F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field.

    Plug it in, switch it on, set the temperature with the front-panel buttons, and insert your probe into the properly sized well. Compare the reading of your device to the display temperature or to an external reference, and the difference is the error in your device. With a proprietary Hart Scientific temperature controller, the 9100S has a display resolution of 0.1 degrees, an accuracy of ±0.5°C, a stability of ±0.1°C, and a stabilization time of just five minutes.

    9102S Dry-Well
    For work in the temperature range of –10°C to 122°C, Hart’s Model 9102S dry-well is another first in the industry, featuring stability to ±0.05°C.

    This dry-well is only four inches high and six inches wide, achieves temperatures as low as –10°C, includes a NIST-traceable calibration, and is stable to ±0.05°C. The Model 9102S is excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient.

    The 9102S has two wells so you can use one for a reference thermometer to increase accuracy. Both wells are 1/2 inch in diameter, and each has inserts available for almost any sensor size. The 9102S also has a battery pack option that gives you approximately four hours of field use when AC power is unavailable.

    Specifications

    9100S 9102S
    Range
     
    35 °C to 375 °C (95 °F to 707 °F)
     
    –10 °C to 122 °C (14 °F to 252 °F) at23 °C ambient
    Accuracy
     
    ± 0.25 °C at 50 °C; ± 0.25 °C at 100 °C; ± 0.5 °C at 375 °C ± 0.25 °C
     
    Stability
     
    ± 0.07 °C at 50 °C; ± 0.1 °C at 100 °C; ± 0.3 °C at 375 °C ± 0.05 °C
     
    Well-to-Well Uniformity ± 0.2 °C with sensors of similar size at equal depths within wells
    Heating Times 35 °C to 375 °C: 9.5 minutes ambient to 100 °C: 10 minutes
    Stabilization 5 minutes 7 minutes
    Cooling Times 375 °C to 100 °C: 14 minutes ambient to 0 °C: 10 minutes
    Well Depth
     
    102 mm (4 in);1.6 mm (1/16 in) hole is 89 mm (3.5 in) deep 102 mm (4 in)
     
    Removable Inserts
     
     
     
    N/A
     
     
     
    Available in sizes from 1.6 mm (1/16 in) to 11.1 mm (7/16 in) [6.4 mm (1/4 in) and 4.8 mm (3/16 in) included]
    Power
     
    115 V ac (± 10 %), 55–65 Hz, 1.5 A or 230 V ac (± 10 %), 0.8 A, 45–55 Hz, 175 W 94-234 V ac (± 10 %), 50/60 Hz, 60 W;or 12 VDC
     
    Size (HxWxD)
     
    57 x 125 x 150 mm(2.25 x 4.9 x 6.1 in) 99 x 140 x 175 mm(3.9 x 5.5 x 6.9 in)
    Weight 1 kg (2 lb 3 oz) 1.8 kg (4 lb)
    Computer Interface RS-232 included with free Interface-it software
    NIST-TraceableCalibration
     
     
    Data at 50 °C, 100 °C, 150 °C, 200 °C,250 °C, 300 °C, and 375 °C Data at –10 °C, 0 °C, 25 °C, 50 °C, 75 °C,100 °C, and 122 °C
     
    Model NameDescriptionPrice List
    9100S-A

    HDRC Handheld Dry-Well A

    On Request
    9100S-B

    HDRC Handheld Dry-Well B

    On Request
    9100S-C

    HDRC Handheld Dry-Well C

    On Request
    9100S-D

    HDRC Handheld Dry-Well D

    On Request
    9102S

    HDRC Handheld Dry-Well

    On Request

    Batteries, Chargers and AdaptersPrice List
    9320A9320AOn Request

    Cases and HolstersPrice List
    93009300On Request
    93089308On Request

    OptionsPrice List
    3102-03102-0On Request
    3102-13102-1On Request
    3102-23102-2On Request
    3102-33102-3On Request
    3102-43102-4On Request
    3102-53102-5On Request
    3102-63102-6On Request
    3102-73102-7On Request
    3102-83102-8On Request
    Search Fluke
    ResourcesProducts
    Find Resources

    Home | Site Map | Fluke Corporation  | Terms and Conditions | Privacy Statement | Disclaimer© 1995 - 2013 Fluke Corporation