Keeping your world up and running.
Home  |  Products  |  Product Selection Guide - Portable Oscilloscopes
Product Selection Guide - Portable Oscilloscopes

Product Selection Guide - Portable Oscilloscopes (Scopemeters)

Portable Oscilloscopes >

Select the product attributes needed for your application. The products that match those attributes will appear on the left.

Application
Application
Automotive
Building Control & HVAC Systems
Electrical
Electro-Mechanical
Electronic Audio/Video Security Systems Field Service
Electronic Avionics Systems Field Service
Electronic Medical Imaging Field Service
Industrial Automation Controls
Industrial Process Control
Acquisition
Bandwidth
20 MHz
40 MHz
60 MHz
100 MHz
200 MHz
Sample Rate
25 Msa/s real time / 1.25 Gsa/s equivelent time
25 Msa/s real time / 2.5 Gsa/s equivelent time
625 Msa/s
1.25 Gsa/s
2.5 Gsa/s
Inputs
Input Channels
2 Scope & 2 DMM
2 Scope & DMM
4 Scope
Independantly Isolated Inputs
Common reference
1000 V CAT II I/ 600 V CAT IV
1000 V CAT III / 600 V CAT IV
Rated Input Voltage
600 V CAT III
1000 V CAT III / 600 V CAT IV
Floating Voltage (Maximum voltage between earth ground and any terminal either signal input or shielding)
600 V CAT III
1000 V CAT III / 600 V CAT IV
Triggering
Connect & View
Continious Autoset
Advanced Trigger Capabilites
Single, Free, Edge, Video, External
Single, Free, Edge, Pulse Width, Dual Slope, N-Cycle, Video, External
Measurement & Analysis Functions
Cursors
Yes
Advanced Automatic Measurements
Vpwm AC & Vpwm AC+DC. Special amplitude measurment on pulse width modulated frquency motor drive
1) Vpwm AC & Vpwm AC+DC. Special amplitude measurment for pulse width modulated frequency motor drive.
2) mAs current over time between cursors, V*s Voltage over time between cursors
Power Application Measurements
Power (W), VA, VAR and Power Factor (PF)
FFT/ Harmonic Display
Harmoncs, up to 33rd
FFT, frequency spectrum
TrendPlot™
Dual trend plot up to 16 days
Dual trend plot up to 22 days
Quad trend plot greater than 22 days
ScopeRecord™
Dual input up to 48 Hrs
Any 4 inputs up to 48 Hrs
Auto capture last 100 Screens
Replay last 100 screens
Pass/Fail waveform reference
Compare reference store on pass or fail
Digital Persistance
Short, Med, Long & infinite
BusHealth industrial network physical layer test
BusHealth Test
Interface
PC Interface
Optically Isolated RS-232 Intreface
Isolated USB
External Memory
USB memory device port
PC Interface cable accessory
Optical RS-232 to USB optional
close
Info
Comparison is limited to 4 or fewer products. Please continue selecting attributes.
close
Info
Please check 4 or fewer products for Compare
Home   |   Site Map   |   Fluke Corporation   |   Safety Notices
Privacy Statement   |   Terms of Use  |   Terms and Conditions of Sale
© 1995 - 2018 Fluke Corporation