The most trusted tools in the world
Home  |  Products  |  Clamp Meters  |  

Fluke 325 True-rms Clamp Meter

Work with the best.
The Fluke 325 True-rm Clamp Meter offers big features in a small form factor.
Fluke 325
Fluke 325
Fluke 325 Clamp Meter
Fluke 325 Clamp Meter Kit
Fluke 325 Clamp Meter in Action
Fluke rugged. Fluke reliable. Fluke precise.

True-rms measurements and optimized ergonomics make the 320 Series Clamp Meters the best general troubleshooting tools for commercial and residential electricians. The 323, 324 and 325 are designed to verify the presence of load current, AC voltage and continuity of circuits, switches, fuses and contacts. These small and rugged clamp meters are ideally suited for current measurements up to 400 A in tight cable compartments. The Fluke 325 also offers DC current and frequency measurements.
Measurement capability
  • 400 A ac and dc current measurement
  • 600 V ac and dc voltage measurement
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Resistance measurement up to 40 kΩ with continuity detection
  • Temperature and capacitance measurement
  • Frequency measurement

Features
  • Slim, ergonomic design
  • Large, easy to read backlight display
  • CAT IV 300V/CAT III 600 V safety rating
  • Hold button
  • Two-year warranty
  • Soft carrying case
Specifications
  323 324 325
AC current Range 400.0 A 40.00 A/400.0 A 40.00 A/400.0 A
Accuracy 2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)
1.5 % ± 5 digits
(45 Hz to 400 Hz)
Note: Add 2 % for
position sensitivity
2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)
DC current Range - - 40.00 A/400.0 A
Accuracy - - 2 % ± 5 digits
AC voltage Range 600.0 V 600.0 V 600.0 V
Accuracy 1.5 % ± 5 digits 1.5 % ± 5 digits 1.5 % ± 5 digits
DC voltage Range 600.0 V 600.0 V 600.0 V
Accuracy 1.0 % ± 5 digits 1.0 % ± 5 digits 1.0 % ± 5 digits
Resistance Range 400.0 Ω/ 4000 Ω 400.0 Ω/ 4000 Ω 400.0 Ω/ 4000 Ω/ 40.00 kΩ
Accuracy 1.0 % ± 5 digits 1.0 % ± 5 digits 1.0 % ± 5 digits
Continuity ≤ 70 Ω ≤ 30 Ω ≤ 30 Ω
Capacitance - 0 to 100.0 μF / 100 μF to 1000 μF 0 to 100.0 μF / 100 μF to 1000 μF
Frequency - - 5.0 Hz to 500.0 Hz
AC response True-rms True-rms True-rms
Backlight - Yes Yes
Data hold Yes Yes Yes
Contact temperature - -10.0 °C to 400.0 °C
(14.0 °F to 752.0 °F)
-10.0 °C to 400.0 °C
(14.0 °F to 752.0 °F)
Min/Max - - Yes
Size H x W x D (mm) 207 x 75 x 34 207 x 75 x 34 207 x 75 x 34
Max wire diameter 30 mm (600 MCM) 30 mm (600 MCM) 30 mm (600 MCM)
Weight 265 g 208 g 283 g
Category rating CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
Warranty Two-year Two-year Two-year
Model NameDescriptionPrice List
Fluke 325325 True-rms Clamp Meter
Included accessories
  • Test leads
  • Soft case
  • User's manual
On Request

Cases and HolstersPrice List
CAMO-37Camouflage Carrying CaseOn Request
Fluke MeterCleaner WipesFluke MeterCleaner WipesOn Request

Test LeadsPrice List
TL223TL223 Electrical Test Lead SetOn Request
Related Products
 
 Fluke 375 True-rms AC/DC Clamp Meter »
 
 Fluke 376 True-rms AC/DC Clamp Meter with iFlex™ »
 
 Fluke 419D Laser Distance Meter  »
Home   |   Site Map   |   Fluke Corporation   |   Safety Notices  |   Privacy Statement   |   Terms of Use  |   Terms and Conditions of Sale © 1995 - 2014 Fluke Corporation