Electrical tester with OpenJaw™ Current
The Fluke T5 Electrical Testers let you check voltage, continuity and current with one compact tool. With the T5, all you have to do is select volts, ohms, or current and the tester does the rest. OpenJaw™ current lets you check current up to 100A - without breaking the circuit. Its tough test leads stow neatly in the back of the tester, making it easy to tote the T5 in your tool pouch. Detachable SlimReach™ test probes are customized for national electrical standards. The test leads accept optional accessories such as clips and specialty probes. The optional H5 holster lets you clip the T5 onto your belt.
|
- Automatically measures volts ac and volts dc with precise digital resolution
- Displays resistance to 1000Ω
- Easy and accurate OpenJaw™ current measurement
- Continuity beeper
- Compact design with neat probe storage
- Rugged enough to withstand a 10-foot (3m) drop
- Detachable SlimReach™ probe tips are customized for national electrical standards
- Test leads accept Fluke accessory test clips
- 600V model
- Can stay connected much longer than solenoid type tester
- Auto off mode to conserve battery life
- Optional holster attaches to a belt and neatly stows test leads
- AC current
- Display hold
Safety Conformance
All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.
|
|
| Specifications |
| Jaw opening |
12.9 mm (0.5 in) |
| Max wire size |
1/0 THHN Cable |
| Current range ac rms |
0 to 100.0 A |
| Accuracy ac current (50/60 Hz) |
3 % ± 3 counts |
| AC Response |
Averaging |
| Voltage range ac |
0 to 600 V |
| Accuracy ac voltage |
1.5 % ± 2 counts |
| Voltage range dc |
0 to 600 V |
| Accuracy dc voltage |
1 % ± 1 count |
| Resistance range |
0 to 1000 Ω |
| Continuity beeper threshold |
On at <25 Ω, off at >400 Ω |
| Volts indicator LED threshold |
Guaranteed on by 30 V ac |
| Environmental Specifications |
| Operating Temperature |
-10 °C to 50 °C |
| Storage Temperature |
-30 °C to 60 °C |
| Humidity (Without Condensation) |
0 % to 95 % (5 °C to 30 °C); 0 % to 75 % (30 °C to 40 °C);
0 % to 45 % (40 °C to 50 °C) |
| Dust/water resistance |
Yes |
| Operating Altitude |
2000 meters max |
| Temperature Coefficient |
0.1 x (specified accuracy)/°C (<18 °C or >28 °C) |
| Safety Specifications |
| Overvoltage category |
CAT III 600 V ac/dc (EN61010-1) |
| Agency Approvals |
UL, CSA, and VDE |
| Maximum voltage |
Between any terminal and earth ground |
| Mechanical and General Specifications |
| Size |
30.5 mm x 51 mm x 203 mm |
| Weight |
300g |
| Warranty |
Two-years |
| Battery Life |
200 hour zinc chloride, 400 hour alkaline |
| Battery type |
2 x AA |
| Low battery indicator |
Yes |
| Current sensor opening |
12.9 mm |
| Calibration cycle |
1 year |
| Test leads |
| Type: |
Heavy duty, flexible leads rated for 1000V use. |
|
Field replaceable leads terminate in male shrouded banana plugs |
| Probes: |
One red, one black. |
|
Detachable Slim-Reach™ probe tips |
| Styles: |
TP1 Slim Reach™ Test Probes |
|
|
| Modèle | Informations pour la commande | Prix courants | | Fluke T5-600 | Voltage Tester
Includes:
- 600V Voltage, continuity and current tester
- 4 mm detachable probes
- Instruction sheet
| Sur Demande |
| Clips | Prix courants | | AC220 | AC220 Jeu de sondes à pince crocodile SureGrip™ | Sur Demande | | AC285 | Pinces crocodile AC285 SureGrip™ | Sur Demande |
| Test Probes | Prix courants | | TLK291 | TLK291 Fused test probe set | Sur Demande | | TP1 | TP1 Pointes de touche Slim Reach (pointe plate) | Sur Demande | | TP2 | TP2 Pointes de touche Slim Reach (2 mm) | Sur Demande | | TP4 | TP4 Pointes de touche Slim Reach (4 mm) | Sur Demande |
| Sacoches, boîtiers, mallettes et étuis | Prix courants | | C101 | C101 Mallette | Sur Demande | | C520A | C520A Sacoche en cuir pour instrument de test | Sur Demande | | H5 | H5 Etui pour testeur électrique (Fluke T3/T5) | Sur Demande | | T5-Kit | Kit d’accessoires ACC-T5-KIT pour testeur T5 | Sur Demande |
|
|
|
|
|
|
|
|