Ready for Anything

As more and more process plants begin to take advantage of smart transmitters, the need for a new generation of calibrators has emerged-calibrators that can communicate via industry standard digital protocols. The 744 combines HART communication capability to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation.

The 744 does the work of several tools - sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device.
For documentation, the 744 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.

The 744 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis. The 744 also features a powerful built in HART® interface capable of performing nearly all the day-to-day tasks you now perform with a separate communicator.

  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
  • Holds up to a full week of downloaded procedures and calibration results.
  • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
  • Easy to use
  • Three year warranty
  • Bright white dual display. Read both sourced and measured parameters simultaneously.
  • Multi lingual interface
  • Rechargeable NiMH battery for 10 hour uninterrupted use. Includes gas gauge.
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.
  • Delivered with DPC/Track Sample software.
  • Compatible with many Asset Management software packages.
HART Capabilities
The 744 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers the communication capabilities of the 275 HART communicator.
  • Requires no external box or second tool for everyday HART calibration and maintenance.
  • Offers fast HART communication.
  • Supports popular models of HART transmitters, with more devise-specific command support than any other HART field calibrator.
  • Works with multiple masters, burst mode, and multi-drop configurations.
  • Is easy to update as additional instruments are added and new HART versions are released.
  • Interrogate to determine device type, manufacturer, model, tag.
  • Reconfigure the sensor mapping of dual sensor temperature transmitters.
  • Read HART PV function and smart transmitter digital output while measuring analog mA output.
  • Read and write HART configuration functions to make field adjustments to PV range points, damping, and other top-level configuration settings.
  • Re-label smart transmitters by reading and writing to the HART tag field.


Versatile HART Protocol support



The 744 supports the commands contained in HART protocol Version 5.7. With 2 MB of memory, the 744 supports a substantial set of HART instructions:

  • Universal commands provide functions that are implemented in all field devices, for example, read manufacturer and device type, read primary variable (PV), or read current output and percent of span.
  • Common practice commands provide functions that are common to many but not all field devices, for example read multiple variables, set damping time, or perform loop test.
  • Device-specific commands provide functions that are unique to a particular field device, for example sensor trim.


HART Operating Modes Supported
  • Point to Point operation , the most commonly used mode, connects the 744 to a single HART device in a 4-20 mA loop.
  • In Multi-Drop mode , several HART instruments can be bussed together. The 744 searches for each, identifies addresses in use, and allows you to select the instrument for calibration and related operations.
  • In Burst Mode, the HART instrument transmits bursts of data without waiting to be interrogated by a master unit. The 744 can take transmitters out of burst mode during test or calibration, then later restore them to burst mode.


Fluke 744 Final Release Firmware Upgrade »

Pressure Modules

Covers virtually any pressure application including gauge, differential, dual (compound), absolute, and vacuum.

  • Display pressure readings in any of 10 different pressure units you specify in the calibrator setup.
  • Rugged urethane molded cases protect the modules from rough handling and harsh conditions.
  • Features internal temperature compensation from 0º to 50º C for full accuracy performance.
  • Includes NIST-traceable calibration certificate.
  • Modules can be calibrated locally, helping to control costs.
A family of 29 optional pressure modules provides pressure calibration and measurement capabilities. Twenty-eight modules are available, with basic accuracy specs to 0.05%. Ranges start at 0 — 1 in H20 (0 — .25kPa) and go to 0 — 10,000 psi (0 — 70,000 kPa). Additional information about pressure modules is available on the Pressure Modules Home Page.

Automated Procedures

Allow you to quickly set up powerful, automated calibration procedures for linear transmitters, DP flow transmitters, and one- and two-point limit switches. Simply select the appropriate measure and/or source functions and fill out the procedure template. The 740 Series does the rest. It quickly performs the test, calculates the errors, and displays the final results, highlighting out of tolerance points.

Custom Units

Enable you to map one unit to another, such as mV to ºC or ºF. Allows you to use the Fluke 740 Series with millivolt output accessories such as the Fluke 80T-IR Temperature Probe, and to document tests using non-supported units such as parts per million or revolutions per minute.

User-entered Values

Enables technicians to record calibration results that were sourced and/or measured by other devices such as panel meters or readout-only devices.

Limit Switch Calibration

Procedures perform fast, automated calibration of one and two-point limit switches for voltage, current, temperature, and pressure.

Differential Pressure Flow Instrument Calibration

Routines use a square root function to directly calibrate DP flow instruments.

Additional Features
Multifunctional

Calibrate temperature, pressure, voltage, current, resistance, and frequency. Since it both measures and sources, you can troubleshoot and calibrate all with one rugged tool.

Powerful, yet easy to use

The easy-to-follow menu-driven display guides you through any task. Get up to speed in minutes, not days. Programmable calibration routines enable you to create and run automated as-found/as-left procedures to ensure fast, consistent, calibrations.

Records and documents results

To support your ISO-9000 or regulatory standards the Fluke 744 captures your calibration results, eliminating the need to juggle a pen and pad in the field. The RS-232 interface lets you transfer the results to a PC, thus saving the time of having to manually transcribe them when you return to the shop.

Truly hand-held

Small enough to fit easily into a tool bag and to use in tight spaces. Runs an entire shift on a rechargeable NiMH battery pack.

Rugged and reliable

Count on Fluke's rugged design to deliver top accuracy and reliability in harsh environments. Overmolded urethane case stands up to rough handling in industrial environments.

Bright white display

Lets you read your results in any kind of light.

Soft keys

Provide one-touch access to enhanced functions such as task lists, automated procedures, scaling, min/max, stepping and ramping, and review memory.

Three operating modes

Measure, Source, or simultaneous Measure/Source, - enable technicians to troubleshoot, calibrate, or maintain instrumentation with just one tool.

Multi-lingual interface

Displays instructions in English, French, German, Spanish, and Italian.

Built-in algebraic calculator

With four functions-plus square root-stores, recalls, and performs calculations required for setting up instruments or evaluating data in the field. Use it to set the source function to a calculated value. There's no need to carry a pencil and paper or a separate calculator.

Programmable measurement delay

Inside automated procedures permits calibrating instruments that respond slowly.

Measurement Accuracy
Voltage DC
110.000 mV  0.025%+0.015% *
1.10000 V  0.025%+0.005% *
11.0000 V  0.025%+0.005% *
110.000 V  0.05%+0.005% *
300.00 V  0.05%+0.005% *
Voltage AC
20 to 40 Hz  2% + 10
40 to 500 Hz  0.5% + 5
500 to 1 kHz  2% + 10
1 kHz to 5 kHz  10% + 20
Ranges:  1.1000, 11.000, 110.00, 300V
Current DC
30.000 mA  0.01% + 0.015% *
110.00 mA  0.01% + 0.015% *
Resistance
11.000 Ω  0.05% + 50 mΩ
110.00 Ω  0.05% + 50 mΩ
1.1000 kΩ  0.05% + 500 mΩ
11.000 kΩ  0.1% + 10 Ω
Frequency
1.00 to 109.99 Hz  0.05 Hz
110.0 to 1099.9 Hz  0.5 Hz
1.100 to 10.999 kHz  5 Hz
11.00 to 50.00 kHz  50 Hz
Pressure
Accuracy  from 0.025% of range using any of 29 pressure modules.
 Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
 (for detailed specifications refer to pressure modules in options and accessories)
Note
*  (% of reading + % of full scale)

Source Accuracy
Voltage DC
110.000 mV  0.01%+0.005% *
1.10000 V  0.01%+0.005% *
15.0000 V  0.01%+0.005% *
Current DC
22.000 mA (Source)  0.01%+ 0.015% *
22.000 mA (Simulate)  0.02% + 0.03% *
Resistance
11.000 Ω  0.01% + 20 mΩ
110.00 Ω  0.01% + 40 mΩ
1.1000 kΩ  0.02% + 500 mΩ
11.000 kΩ  0.03% + 5Ω
Frequency
0.00 to 10.99 Hz  0.01 Hz
11.00 to 109.99 Hz  0.1 Hz
110.0 to 1099.9 Hz  0.1 Hz
1100 to 21999 Hz  2 Hz
22.000 to 50.000 kHz  5 Hz
Note
*  (% of reading + % of full scale)

RTDs and Thermocouples
Measure Accuracy:
10 Ω Cu (427):  2 °C
100 Ω Pt (3916):  0.3 °C
100 Ω Pt (3926):  0.3 °C
100 Ω Pt (385):  0.3 °C
200 Ω Pt (385):  0.3 °C
500 Ω Pt (385):  0.3 °C
1000 Ω Pt (385):  0.3 °C
120 Ω Ni (672):  0.3 °C
note:  For 2-and 3-wire measurement, add 0.4°C
E:  0.3 °C
N:  0.5 °C
J:  0.3 °C
L:  0.3 °C
K:  0.3 °C
T:  0.3 °C
U:  0.3 °C
B:  0.9 °C
R:  1.0 °C
S:  0.9 °C
C:  0.6 °C
BP:  1.2 ºC
XK:  0.4 ºC
note:  Accuracy with external cold junction, for internal junction add 0.2 °C
Source Accuracy:
10 Ω Cu (427):  1 °C
100 Ω Pt (3916):  0.1 °C
100 Ω Pt (3926):  0.1 °C
100 Ω Pt (385):  0.1 °C
200 Ω Pt (385):  0.1 °C
500 Ω Pt (385):  0.1 °C
1000 Ω Pt (385):  0.1 °C
120 Ω Ni (672):  0.1 °C
note:  For 2-and 3-wire simulation, add 0.4 °C
E:  0.2 °C
N:  0.3 °C
J:  0.2 °C
L:  0.2 °C
K:  0.3 °C
T:  0.3 °C
U:  0.3 °C
B:  0.8 °C
R:  0.9 °C
S:  0.9 °C
C:  0.6 °C
BP:  0.5 ºC
XK:  0.4 ºC
note:  Accuracy with external cold junction, for internal junction add 0.2 °C

Technical Data
Data Log Functions
Measure functions:  Voltage, current, resistance, frequency, temperature, pressure
Reading rate:  1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length:  8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions
Source functions:  Voltage, current, resistance, frequency, temperature
Rate:  4 steps/second
Trip detect:  Continuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
Voltage:  Selectable, 24 V or 28 V
Accuracy:  5%
Maximum current:  22 mA, short circuit protected
Maximum input voltage:  30 V DC
Step Functions
Source Functions  Voltage, current, resistance, frequency, temperature
Manual Step  Selectable step, change with arrow buttons
Autostep  Fully programmable for function, start delay, stepvalue, time per step, repeat

Environmental Specifications
Operating Temperature
 -10 °C to +50 °C
 -20 °C to +50 °C *
Storage Temperature
 -20 °C to +60 °C
Dust/water resistance
 Meets IP52, IEC 529
Operating Altitude
 2800 m
Note
*  Except frequency and AC

Safety Specifications
Agency Approvals
 CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993

Mechanical & General Specifications
Size
 130 x 236 x 61 mm (5.1“ x 9.3” x 2.4”)
Weight
 1.4 kg (3 lbs., 1oz.)
Batteries
NiMH:  7.2V, 3.5 Ah
Battery Life
 >10 hours typical
Battery Replacement
 Via snap-shut door without opening calibrator; no tools required
Side port connections
 Pressure module connector
 RS-232 connector for PC interface cable and for HART communication cable
 Connection for optional battery eliminator
Data storage capacity
 1 week of calibration results
90 day specifications
 The standard specification interval for the 744 is 1 and 2 years.
 Typical 90 day measurement and source accuracy can be estimated by
 dividing the one year "% of reading" or "%of output" specifications by 2.
 Floor specifications, expressed as "% of full scale" or
 "counts" or "ohms" remain constant.
Model NameDescription
Fluke 744 Documenting Process Calibrator-HART including:
  • BC7217 battery charger
  • BP7235 battery pack
  • DPC/TRACK Sample Software
  • Instruction manual
  • NIST-traceable calibration report and data
  • One set of TP220 test probes
  • Serial port cable, HART communications cable
  • Two sets of AC220 test clips
  • Two sets of TL224 industrial test leads

Clips
AC220AC220 SureGrip™ Alligator Clip Set
AC280AC280 SureGrip™ Hook Clips
AC285AC285 SureGrip™ Alligator Clip Set

Test Probes
TP74TP74 Lantern Tip Test Probes
TP920TP920 Test Probe Adapter Kit

Differential Pressure Modules
700P00700P00 Differential Pressure Module (2.5 mbar)
700P01700P01 Differential Pressure Module
700P02700P02 Differential Pressure Module (70 mbar)
700P03700P03 Differential Pressure Module (340 mbar)
700P04700P04 Differential Pressure Module (1000 mbar)

Differential Pressure Module Wet
700P22700P22 Differential Pressure Module Wet (70 mbar)
700P23700P23 Differential Pressure Module Wet (340 mbar)
700P24700P24 Differential Pressure Module Wet

Absolute Pressure Modules
700PA3700PA3 Absolute Pressure Module (340 mbar)
700PA4700PA4 Absolute Pressure Module
700PA5700PA5 Absolute Pressure Module (2 bar)
700PA6700PA6 Absolute Pressure Module (7 bar)

Batteries, Chargers and Adapters
BC7217BC7217 Battery Charger
BP7235BP7235 NiMH Battery Pack

Cases and Holsters
C700C700 Hard Case (700 Series)
C75C75 Accessory Case
C781C781 Meter Case
C789C789 Soft Meter Case
Fluke MeterCleaner WipesFluke MeterCleaner Wipes

Connectors
700BCA700BCA Bar Code Adapter
700BCW700BCW Bar Code Wand

Dual Pressure Modules
700PD2700PD2 Dual Pressure Module (± 70 mbar)
700PD3700PD3 Dual Pressure Module (± 340 mbar)
700PD4700PD4 Dual Pressure Module (±1000 mbar)
700PD5700PD5 Dual Pressure Module (-1000/+2000 mbar)
700PD6700PD6 Dual Pressure Module (-1000 mbar/+6.9 bar)
700PD7700PD7 Dual Pressure Module ( -1000 mbar/+13.8 bar)

Software
750SWFluke 750 SW DPC/TRACK2 Software

Vacuum Pressure Modules
700PV3700PV3 Vacuum Pressure Module (-340 mbar)
700PV4700PV4 Vacuum Pressure Module( -1000 mbar)

Temperature
700TC2700TC2 Thermocouple Plug Kits (5 types)
80CJ-M80CJ-M Male Mini Connectors (Type J)
80CK-M80CK-M Male Mini Connectors (Type K)
80PJ-180PJ-1 Bead Probe
80PJ-EXT80PJ-EXT Extension Wire Kit (Type J)
80PK-180PK-1 Bead Probe (Type K)
80PK-2480PK-24 Air Probe
80PK-2580PK-25 Piercing Probe
80PK-2680PK-26 General Purpose Probe
80PK-980PK-9 General Purpose Probe (Type K)
80PK-EXT80PK-EXT Extension Wire Kit (Type K)
80PT-2580PT-25 SureGrip Piercing Temperature Probe
80PK-2280PK-22 SureGrip™ Immersion Temperature Probe
80PK-2780PK-27 SureGrip™ Industrial Surface Temperature Probe
80PK-880PK-8 Pipe Clamp Temperature Probe

Test Leads
TL940TL940 Mini-Hook Test Lead Set
TL950TL950 Mini-Pincer Test Lead Set
Mini Temp | Infrared Thermometer | Infrared Gun | Contact Thermometer
Home  |   Site Map  |   Fluke Corporation  |  Safety Notices
Privacy Statement  |  Terms of Use   |  Terms and Conditions of Sale
© 1995 - 2014 Fluke Corporation