  • Insulation test range:
    • 1507: 0.01 MΩ to 10 GΩ
    • 1503: 0.1 MΩ to 2000 MΩ
  • Insulation test voltages:
    • 1507: 50 V, 100 V, 250 V, 500 V, 1000 V
    • 1503: 500 V, 1000 V
  • Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio (only available on the1507)
  • Make repetitive tests simple and easy with the 1507’s Compare (Pass/Fail) function (only available on the 1507)
  • Repetitive or hard-to-reach testing is easy with the remote test probe
  • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
  • Auto-discharge of capacitive voltage for added user protection
  • AC/DC voltage: 0.1 V to 600 V
  • 200 mA Continuity
  • Resistance: 0.01 Ω to 20.00 kΩ
  • Save battery power with auto power off
  • Read measurements easily with large, backlit display
  • CAT IV 600 V overvoltage category rating for added user protection
  • Remote probe, test leads, probes and alligator clips included with each tester
  • Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
  • Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
  • One year warranty

AC/DC Voltage Measurement
Accuracy
Range  600.0 V
Resolution  0.1 V
50 Hz to 400 Hz ± (% of Rdg + Digits)  ± (2 % + 3)
Input impedance
 3 MΩ (nominal), < 100 pF
Common mode rejection ratio (1 kΩ unbalanced):
 > 60 dB at dc, 50 or 60 Hz
Overload Protection
 600 V rms or dc

Earth bond resistance measurement
Range/Resolution
20.00 Ω  0.01 Ω
200.0 Ω  0.1 Ω
2000 Ω  1.0 Ω
20.00 kΩ  0.01 kΩ
Accuracy
 ± (1.5 % + 3)
Overload Protection
 2 V rms or dc
Open Circuit Test Voltage
 > 4.0 V, < 8 V
Short circuit current
 > 200.0 mA

Insulation specifications
Measurement Range
1507:  0.01 MΩ to 10 GΩ
1503:  0.01 MΩ to 2000 MΩ
Test voltage
1507:  50 V, 100 V, 250 V, 500 V, 1000 V
1503:  500 V, 1000V
Test Voltage Accuracy
 + 20 %, - 0 %
Short circuit current
 1 mA nominal
Auto Discharge
 Discharge time < 0.5 second for C = 1 µF or less
Live circuit indicator
 Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum Capacitive Load
 Operable with up to 1 µF load
Measure Accuracy:
50 V:  ±(3 % + 5)
100 V:  ±(3 % + 5)
250 V:  ±(1.5 % + 5)
500 V:  ±(1.5 % + 5)
1000 V:  ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ

General Specifications
Maximum voltage applied to any terminal:
 600 V ac rms or dc
Storage Temperature
 -40 °C to 60 °C (-40 °F to 140 °F)
Operating Temperature
 -20 °C to 55 °C (-4 °F to 131 °F)
Temperature Coefficient
 0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F)
Relative Humidity
 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)
 0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)
 0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration
 Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Shock
 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)
Electromagnetic compatibility:
 In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)
Safety
 Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
Certifications:
 CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
Batteries
 Four AA batteries (NEDA 15A or IEC LR6)
Battery Life
Insulation test use:  Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements:  Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.
Size
 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)
Weight
 550 g (1.2 lb)
IP Rating
 IP40
Altitude
Operating:  2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage):  12,000 m
Over-range capability:
 110 % of range
Included accessories:
 TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe
Model NameDescription
Fluke 1507Insulation Tester
Includes:
  • Remote probe
  • Test leads
  • Test probes
  • Alligator clips
  • User documentation
Fluke 1503Insulation Tester
Includes:
  • Remote probe
  • Test leads
  • Test probes
  • Alligator clips
  • User documentation

Cases and Holsters
C101C101 Hard Case
CXT170CXT170 Extreme Case
C25C25 Large Soft Case for DMMs
CAMO-37Camouflage Carrying Case
CAMO-C25


CAMO-C25/BD


CAMO-C25/WL


CAMO-C25/WD


CAMO-C25/FO


Camouflage Carrying Case for Fluke Meters
(DESERT DIGITAL)

Camouflage Carrying Case for Fluke Meters
(BLUE DIGITAL CAMO)

Camouflage Carrying Case for Fluke Meters
(WOODLAND CAMO)

Camouflage Carrying Case for Fluke Meters
(WOODLAND DIGITAL)

Camouflage Carrying Case for Fluke Meters
(FOREST CAMO)

TPAK

Fluke TPAK ToolPak™ Magnetic Meter Hanger Kit includes:

  • 9 inch hook and loop strap
  • Universal hanger clip
  • Hook hanger for non magnetic surfaces
  • Strong magnet

Test Leads
TL225TL225 SureGrip™ Stray Voltage Adapter Test Lead Kit
Home  |   Site Map  |   Fluke Corporation  |  Safety Notices
Privacy Statement  |  Terms of Use   |  Terms and Conditions of Sale  |  Terms and Conditions of Service
© 1995 - 2017 Fluke Corporation