 Fluke 719
Forget the Hassle of Hand Pumping

Now you can calibrate and test pressure devices quickly and easily with one hand, saving valuable time. With the innovative, built-in electric pump, the Fluke 719 Electric Pressure Calibrator provides pressure calibration at your fingertips!

Use the programmable pump limit settings to eliminate over-pressurization, and to set ‘pump to’ pressure values. The unique cleanout port design reduces pump failures, and makes the 719 easy to clean without repair. The compact, lightweight form, combined with one-handed calibration, makes this pressure calibrator the ideal tool for busy process professionals.

Pressure calibration made easy, by a name you know and trust for all your process calibration needs.

Fluke 719

Key Features:

  • Electric pump for one handed pressure calibration
  • Best in class pressure measurement uncertainty of 0.025%
  • Measure and source mA with best in class 0.015% accuracy
  • Precision pressure adjust vernier for accurate pressure calibration
  • Variable release rate bleed valve for easy pressure adjustment
  • Ideal performance for high accuracy transmitter calibration
  • 30 PSI and 100 PSI pressure ranges
  • Programmable pressure calibrator pump limit:  
    • eliminates over-pressurization
    • allows the user to program target pressures for pumping
  • Extended pressure measurement range with any of 29 700Pxx Pressure Modules
  • Source mA with simultaneous pressure measurement to test valves and I/Ps
  • Simulate mA signals to troubleshoot 4-20 mA loops
  • Test pressure switches with built in switch test function
  • Power transmitters during test using 24 V loop supply with simultaneous mA measurement
  • Pressure Calibrator includes proven cleanout ports reduce pump failures

General Specifications
Storage temperature
 -30 °C to 60 °C
Operating temperature
 -10 °C to 55 °C
Relative humidity
 95 % (-10 °C to 30 °C)
 75 % (30 °C to 40 °C)
 45 % (40 °C to 50 °C)
 35 % (50 °C to 55 °C)
Shock
 1 meter drop test
Safety
 CSA C22.2 No. 1010.1:1992
EMC
 EN50082-1:1992 and EN55022:1994 Class B
Size (HxWxL)
 60 mm x 87 mm x 210 mm
 (2.19 in x 3.41 in x 8.28 in)
Weight
 912 g (2 lb)
Battery
 Two 9 V alkaline batteries
Battery life
 12 hours with 12 mA into 500 Ω, 200 pump cycles to 100 psi, 500 pump cycles to 30 psi
Warranty
 Three-years, one year for pump

Specification:
Fluke-719 30G
Range  -12 to 36 psi, -850 mbar to 2.4 bar
Resolution  0.001 psi, 0.1 mbar
Accuracy  0.025 % range for 6 months
 0.035 % of range for one (1) year
Fluke-719 100G
Range  -12 to 120 psi, -850 mbar to 8 bar
Resolution  0.01 psi, 1 mbar
Accuracy  0.025 % range for 6 months
 0.035 % of range for one (1) year
mA
Range  0 to 24 mA
Resolution  0.001 mA
Accuracy  .015 % Rdg + 2 counts
Notes  Max load, 1000 Ω, 750 Ω ohm in HART mode
Loop supply
Range  24 V dc
Resolution  N/A
Accuracy  ± 10 %

Pump specifications
Maximum pressure generation
 120 PSI (8 BAR) (100 PSI model)
Pump to
 - 30 PSI in less than 15 seconds*
 - 100 psi in less than 45 seconds*
 *(with 1 meter of 1/8 inch test hose)
Pump cycles between rebuilds
 5000
Total pump life
 20,000 calibration cycle
Model NameDescriptionPrice List
Fluke 719 30G Electric Pressure Calibrator, 30 psi, 2 bar

All Models Include:

  • Protective Yellow Holster
  • Instructions Sheet (15 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • Hose Kit
  • NIST - Traceable calibration report and data
On Request
Fluke 719 100GElectric Pressure Calibrator, 100 psi, 7 bar On Request

Differential Pressure ModulesPrice List
700P00700P00 Differential Pressure Module (2.5 mbar)On Request
700P01700P01 Differential Pressure ModuleOn Request
700P02700P02 Differential Pressure Module (70 mbar)On Request
700P03700P03 Differential Pressure Module (340 mbar)On Request
700P04700P04 Differential Pressure Module (1000 mbar)On Request

Differential Pressure Module WetPrice List
700P22700P22 Differential Pressure Module Wet (70 mbar)On Request
700P23700P23 Differential Pressure Module Wet (340 mbar)On Request
700P24700P24 Differential Pressure Module WetOn Request

Absolute Pressure ModulesPrice List
700PA3700PA3 Absolute Pressure Module (340 mbar)On Request
700PA4700PA4 Absolute Pressure ModuleOn Request
700PA5700PA5 Absolute Pressure Module (2 bar)On Request
700PA6700PA6 Absolute Pressure Module (7 bar)On Request

Dual Pressure ModulesPrice List
700PD2700PD2 Dual Pressure Module (± 70 mbar)On Request
700PD3700PD3 Dual Pressure Module (± 340 mbar)On Request
700PD4700PD4 Dual Pressure Module (±1000 mbar)On Request
700PD5700PD5 Dual Pressure Module (-1000/+2000 mbar)On Request
700PD6700PD6 Dual Pressure Module (-1000 mbar/+6.9 bar)On Request
700PD7700PD7 Dual Pressure Module ( -1000 mbar/+13.8 bar) On Request

Vacuum Pressure ModulesPrice List
700PV3700PV3 Vacuum Pressure Module (-340 mbar)On Request
700PV4700PV4 Vacuum Pressure Module( -1000 mbar)On Request
Home   |   Site Map   |   Fluke Corporation   |   Safety Notices  |   Terms and Conditions   |   Privacy Statement   |   Disclaimer © 1995 - 2013 Fluke Corporation