Ti110 a3001 FC iFlex® Kit
Key features
The Ti110 offers:
- Exclusive IR-OptiFlex™ focus system - ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger
- Always have references handy - IR-PhotoNotes™ annotation system - Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas
- Find problems faster and easier IR-Fusion® technology
- Fluke Connect® App – See It. Save It. Share It. All the facts, right in the field
- Multi-mode video recording - focus-free video in visible light and infrared with IR-Fusion
- Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal)
The 3000 FC Wireless Multimeter offers:
- AC and DC voltage measurements to 1000V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX Recording
- CAT III 1000 V, Cat IV 600 V; IP54
The iFlex™ Wireless Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier. The a3001 FC offers:
- One (1) true-RMS flexible current meter
- One (1) iFlex i2500-10 flexible current probe
- Measure up to 2500 A AC
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
- Inrush function
- Magnetic hanging strap
Product overview: Ti110 a3001 FC iFlex® Kit
Learn more about Fluke Connect
Industrial and commercial professionals can save time and money by identifying problems before they become costly failures with the Ti110 a3001 FC iFlex® Kit. Connect the a3001 FC iFlex® AC Wireless Current Module to your test point and view the results up to 20 meters away on your 3000 FC DMM. The a3001 FC iFlex® module allows you to measure around tight, awkward spaces and/ or sizes and makes wire access easier. The Ti110 thermal camera comes standard with IR Fusion® Technology - the blending of digital and infrared images into a single image making precise documentation quick and easy. Upload all your measurement data to the Cloud via your smart phone and you can analyze and share your inspection results for each piece of equipment from anywhere, with any team member, at any time - only with Fluke Connect.
Simplify and streamline your reporting with our easy to use SmartView® software. Download the SmartView Mobile app and you can use your Apple® iPhone® or iPad® to generate a report and communicate your results directly to your client or colleague from the jobsite.
Specifications: Ti110 a3001 FC iFlex® Kit
Fluke 110 Thermal Camera
Detailed Specifications | |
Key Features | |
IFOV (spatial resolution) | 3.39 mRad |
Detector resolution | 160x120 (19,200 pixels) |
Field of view | 22.5 °H x 31 °V |
Minimum focus distance | 15 cm (6 in) |
Focus system | IR-OptiFlex™ focus system (focus free and manual focus) |
Wireless connectivity | Fluke Connect® app compatible with included wireless SD Card1 |
IR-Fusion® technology | IR-Fusion® AutoBlend™ mode and Picture-in-Picture |
Display | 3.5 inch diagonal (portrait format) |
Design | Rugged, lightweight, ergonomic design for one-handed use |
Thermal sensitivity (NETD) | ≤ 0.10 °C at 30 °C target temp (100 mK) |
Temperature measurement range | -20 °C to +250 °C (-4 °F to +482 °F) |
Built-in digital camera (visible light) | 2 megapixel industrial performance |
Frame rate | 30 Hz or 9 Hz versions |
Data Storage and Image Capture | |
Extensive memory options | Removable 4 Gb SD memory card and 8 Gb wireless SD card (where available); direct download via USB-to-PC connection |
File formats image | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp, .jpg and .avi) files |
SmartView® software | SmartView® software, Fluke Connect®1, and SmartView® Mobile App—full analysis and reporting software |
Voice annotation | 60 seconds maximum recording time per image; reviewable playback on camera |
IR-PhotoNotes™ | Yes (3 images) |
Video recording | Standard |
Battery | |
Batteries (field-replaceable, rechargeable) | One lithium ion smart battery pack with five-segment LED display to show charge level |
AC battery charging system | In-imager charging. Optional two-bay battery charger or optional 12 V automotive charging adapter |
Temperature Measurement | |
Accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
On-screen transmission correction | Yes |
General Specifications | |
Color palettes | 8 standard and 3 Ultra Contrast™: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Color alarms (temperature alarms) | High temperature, low temperature |
User-definable spot markers | 3 user definable spot markers on camera and in SmartView® software |
Center box | Expandable-contractible measurement box with MIN-MAX-AVG temp |
Drop | Engineered to withstand 2 meter (6.5 feet) drop |
Size (H x W x L) | 28.4 cm x 8.6 cm x 13.5 cm (11.2 in x 3.4 in x 5.3 in) |
Weight (battery included) | 0.73 kg (1.6 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Fluke 3000 FC Wireless Digital Multimeter
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications | |||
AC Voltage | |||
Range 1 | Resolution | Accuracy 2 3 4 | |
45 Hz to 500 Hz | 500 Hz to 1 kHz | ||
600.0 mV | 0.1 mV | 1.0 % + 3 | 2.0 % + 3 |
6.000 V | 0.001 V | ||
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V | ||
1 All AC voltage ranges are specified from 1 % of range to 100 % of range. 2 Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3. 4 Do not exceed 107 V-Hz. |
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |||
Function | Range | Resolution | Accuracy |
mV | 600.0 mV | 0.1 mV | 0.09 % + 2 |
V | 6.000 V | 0.001 V | 0.09 % + 2 |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V | 0.15 % + 2 | |
Ω | 600 Ω | 1 Ω | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. |
Ω | 600.0 Ω | 0.1 Ω | 0.5 % + 2 |
6.000 kΩ | 0.001 kΩ | 0.5 % + 1 | |
60.00 kΩ | 0.01 kΩ | ||
60.00 kΩ | 0.1 kΩ | ||
600.0 kΩ | 0.001 MΩ | ||
50.00 MΩ | 0.01 MΩ | 1.5 % + 3 | |
Diode test | 2.000 V | 0.001 V | 1 % + 2 |
µF | 1000 nF | 1 nF | 1.2 % + 2 |
10.00 μF | 0.01 μF | ||
100.0 μF | 0.1 μF | ||
9999 μF1 | 1 μF | 10 % typical | |
1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2. |
AC and DC Current | |||
Function | Range 1 | Resolution | Accuracy |
mA AC (45 Hz to 1 kHz) | 60.00 mA | 0.01 mA | 1.5 % + 3 |
400.0 mA 3 | 0.1 mA | ||
mA DC 2 | 60.00 mA | 0.01 mA | 0.5 % + 3 |
400.0 mA 3 | 0.1 mA | ||
1 All AC current ranges are specified from 5 % of range to 100 % of range. 2 Input burden voltage (typical): 400 mA input 2 mV/mA. 3 400.0 mA accuracy specified up to 600 mA overload. |
Frequency | |||
Range | Resolution | Accuracy 1 | |
99.99 Hz | 0.01 Hz | 0.1 % + 1 | |
999.9 Hz | 0.1 Hz | ||
9.999 kHz | 0.001 kHz | ||
99.99 kHz | 0.01 kHz | ||
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. |
Input Characteristics | ||||||
Function | Overload protection | Input impedance (nominal) | Common mode rejection ratio (1 kΩ unbalance) | Normal mode rejection | ||
1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |||
1100 V RMS | > 10 MΩ < 100 pF | > 60 dB, DC to 60 Hz | ||||
1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |||
Open circuit test voltage | Full scale voltage | Typical short circuit current | ||||
To 6 MΩ | 50 MΩ | |||||
1100 V RMS | < 2.7 V DC | < 0.7 V DC | < 0.9 V DC | < 350 mA | ||
1100 V RMS | < 2.7 V DC | 2.000 V DC | < 1.1 mA |
mA Function | |
Overload Protection | Fused, 44/100 A, 1000 V FAST Fuse |
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum |
MIN/MAX Recording Accuracy | |
DC functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. |
AC functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. |
General Specifications | |
Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS |
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |
Display (LCD) | Update rate: 4/sec Volts, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts |
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 |
Battery life | 250 hours minimum |
RF communications | 2.4 GHZ ISM Band |
RF communication range | Open air, unobstructed: Up to 20m Obstructed, sheetrock wall: Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m |
Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C |
Temperature coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
Relative humidity | 0 % to 90 % (0 °C to 35 °C) 0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C) |
Altitude | Operating: 2,000 m Storage: 12,000 m |
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 |
Certifications | CSA, FCC, CE |
Ingress Protection (IP) rating | IP54 |
Pollution degree | 2 |
Size (H x W x L) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) |
Weight | 340 g (12 oz) |
Warranty | Three years |
Note: Not compatible with Fluke CNX test tools
Fluke a3001 FC Wireless iFlex AC Current Module
Specifications | |
Range | 0.5 A to 2500 A AC |
Resolution | 0.1 A |
Accuracy | 3 % ± 5 digits (5 Hz to 500 Hz) |
Crest factor (50 Hz/60 Hz) | 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 |
LCD w/backlight | 3½ digits |
Log rate/interval | 1 sec minimum/adjustable by PC or front panel |
Battery type | 2 AA, NEDA 15 A, IEC LR6 |
Battery life | 400 hours |
Memory | Record up to 65,000 readings |
RF communications | 2.4 GHZ ISM Band |
RF communication range | Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m |
Operating temperature | -10 °C to +50 °C |
Storage temperature | -40 °C to +60 °C |
Temperature coefficient | Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C) |
Operating humidity | 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C |
Altitude | Operating: 2,000 m Storage: 12,000 m |
EMC | EN 61326-1:2006 |
Safety compliance | IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition |
Safety rating | CAT IV 600 V, CAT III 1000 V |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
Ingress Protection (IP) rating | IP42 |
Pollution degree | 2 |
Jaw opening | 25.4 cm (10 in) coil |
Size (HxWxD) | 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) |
Weight | .22 kg (8 oz) |
Warranty | Three years |
Note: Not compatible with Fluke CNX test tools