Fluke 225C Color ScopeMeter with Industrial Bus Health Test capability
The 225C offers the full functionality of a standard 200 MHz portable oscilloscope yet with the addition of powerful test capabilities for a wide variety of Industrial Bus systems. When in Bus health Test mode, the 225C ScopeMeter will automatically make an analysis of the electrical signals passing through the bus, and compare the parameters to standard values as described in the industry standards for that bus type. Alternatively, the user may select an ‘Eyepattern’ display to visually check the overall signal quality.
Parameters are automatically qualified as ‘good’, ‘weak’ or ‘bad’ based on a comparison to the appropriate industrial standards or to user set reference values. Each of the measured parameters is presented with momentary value and with statistical minimum and maximum values measured over time. The reference values used are also displayed, to give the user an easier grip on the systems behavior. Tested parameters include signal amplitudes, bias voltage, rise- and fall-times, jitter, distortion and noise levels (in-band noise as well as out-of-band noise) depending on the requirements of the associated industry standard.
|
|
The Fluke 225C is the instruments of choice for maintenance specialists who deal with industrial buses and networks as well as with general electronics. You can verify the electrical integrity of your bus and network, performing ‘physical layer tests’ and getting answers quickly and easily.
Based on the 200 MHz or 100 MHz 190C Series Color ScopeMeter test tools, these instruments offer all functions found in the 190C Series, with Bus Health Test capabilities added on top.
Bus Health Test
Bus Health Test analyses the electrical signals on the industrial bus or network and gives a clear “Good, “Weak or “Bad validation mark for each of the relevant parameters, presented next to the actual measurement value. Measured values are compared to standard values based on the selected bus type, or you may set your personal reference values if you need different tolerances.
Automatic analysis and validation of electrical signal parameters
All common bus types are supported
The 225C ScopeMeter test tool supports not just one or two bus systems but all commonly seen industrial buses. From the lower speed AS-i and CAN to the higher speed Ethernet 100Base-T based systems are covered by a single instrument. A simple menu structure allows for selecting the main bus type and, where applicable, sub-types listed in a sub-menu for easy selection. Tested parameters and reference values are then set according the selection made.
All common bus types are supported and accessible through a simple menu structure
Large color screen
The large color screen of the 225C shows the individual parameters with validation, the actual measured value, the minimum and maximum values recorded over time, and the reference values used for the validation. The choice of parameters differs with the bus type and may include bias voltage, signal high- and low-levels, rise- and fall-times, in-band and out-of-band noise levels, jitter, pulse width, baud rate, and more. The activity indicators tell you the data is ongoing and they stop the moment communications come to a halt.
Making test connections
The large screen also gives wiring information for each of the supported bus types, giving the user guidance in making the test connections. A set of break-out adapters is included with the 225C to give access to each of the wires and pins of the commonly used connection systems M12, DB-9 and RJ-45.
On screen ‘help’ information includes visual guidance on making the test connections. The independently isolated input channels of the 225C support truly differential measurements on bus systems.
BHT190 Break-out adapter with DB-9 connectors gives access to all individual wires and pins of the connection system.
Eye-pattern Mode
The Fluke 225C can make the signal quality validation as soon as electrical signals are passed along the network, without looking at the data content. They find errors like improper cable connections, bad contacts, incorrect grounding and missing or superfluous terminators. In the eye-pattern mode, a waveform display is built over successive signal passes to give you a visual indication of overall signal quality, noise levels and signal jitter, using the scope’s user selectable persistence mode.
Eye-pattern mode allows for a visual check of signal quality
Floating independently isolated input channels
Thanks to the independently isolated input channels and the floating inputs, the ScopeMeter test tool can take truly floating differential measurements from balanced 2-wire systems such as RS-485 and CAN, giving a high level of suppression for common mode disturbances and noise. One input channel can be connected to measure the voltage between the two signal wires, and the other can be connected to measure the common mode voltage over ground at the same time, independently. This way, you may also measure the signals passing through the twisted wires of the 100Base-T Ethernet.
Isolated, floating channels give a high immunity to common mode noise and allow for direct measurements on balanced, two-wire systems including Ethernet 100Base-T.
Fluke 225C compared with other ScopeMeter test tools
All ScopeMeter test tools allow you to perform the basic electrical tests (such as copper resistance and isolation tests) on an electrical system or a cable. The Fluke 125 offers a cost-effective solution for making tests on industrial buses and networks, using a common reference (‘ground’) connection. The Fluke 125 also includes a fully featured 40 MHz Industrial ScopeMeter. The 225C gives more extensive industrial bus signal analysis capabilities. Thanks to the isolated channel structure, the 225C gives a far better immunity to common mode noise and disturbances and can measure common mode voltages separately. On top, the 225C comes with higher measurement speeds and give you all the measurement capabilities associated with the 190C Series.
Apart from the Bus Health Test functionality, the 225C incorporates the full functionality of the 199C and 196C Color ScopeMeters.
|
|
For the Fluke 225C, the full specifications of the 199C (196C) applies.
| Specifications |
| Bandwith |
|
| Sample rate: |
|
| Bus health test: |
|
Verifies the electrical parameters of industrial bus systems using automatic measurement and analysis functions. Next to that, an Eyepattern mode is provided for visual inspection of signal quality. |
|
| Parameter classification: |
|
Default values: |
| • |
well within limits = ‘good’, gives green tick mark |
| • |
within specified percentage of the limit values = ‘weak’, gives orange tickmark |
| • |
beyond limit values = ‘bad’, gives red tickmark |
|
Limits values, as a default, are based on industry standard for the selected bus type or may be set by the user. The tolerance band (percentage) taken into account for the classification ‘weak’ may be altered by the user. |
|
| Bus systems supported: |
| • |
AS-i (EN50295, 166 kb/s); |
| • |
CAN-bus (ISO-11898, up to 1 Mb/s); |
| • |
Modbus 232 (EIA-232 up to 115 kb/s); |
| • |
Modbus 485 (EIA-485 up to 10 Mb/s); |
| • |
Foundation Fieldbus H1 (61158 type 1, 31.25 kb/s); |
| • |
Profibus DP (EIA-485 up to 12 Mb/s); |
| • |
Profibus PA (61158 type 1, 31.25 kb/s); |
| • |
Ethernet 10Base2 (coaxial, 10 Mb/s); |
| • |
Ethernet 10BaseT (UTP, 10 Mb/s); |
| • |
Ethernet 100BaseT (100 Mb/s); |
| • |
RS-232 (EIA-232, up to 115 kb/s); |
| • |
RS-485 (EIA-485, up to 10 Mb/s). |
|
| Modes: |
| • |
Waveform Parameter analysis with automatic read-out and parameter validation (good / weak / bad); test limits are based on industry standards or may be set by the user. |
| • |
Eyepattern display mode. |
|
| Measured parameters (where applicable): |
| • |
bias voltage level, |
| • |
signal amplitude, |
| • |
pulse width or baud rate, |
| • |
risetime, |
| • |
fall time, |
| • |
jitter, |
| • |
signal distortion, |
| • |
noise HF, |
| • |
noise LF, |
| • |
in-band noise. |
|
| Eyepattern display mode: |
|
Gives waveform display of bus signals with user selectable persistence of the display. Timebase, attenuator and persistence settings may be altered by the user. |
|
| Persistence modes: |
|
off – short – medium – long – infinite |
|
|
| Cases and Holsters | Price List | | SCC190 | SCC190 Carrying Case, FlukeView Software & Optically Isolated USB Interface Cable | On Request |
| Clips | Price List | | HC200 | HC200 Hook Clip set 2 red, 2 gray | On Request |
| Test Probes | Price List | | RS200 | RS200 Probe-accessories Replacement Set | On Request | | VPS101 | VPS101 – Voltage Probe Set, 1:1, one black | On Request | | VPS210-G | VPS210-G Voltage Probe Set, 200 MHz, Grey (one, grey) | On Request | | VPS210-R | VPS210-R Voltage Probe Set, 200 MHz, Red (one, red) | On Request | | VPS212-G | VPS212-G - Voltage Probe Set, 10:1, one grey | On Request | | VPS212-R | VPS212-R - Voltage Probe Set, 10:1, one red | On Request | | VPS220-G | VPS220-G - Voltage Probe Set, 100:1, one grey | On Request | | VPS220-R | VPS220-R – Voltage Probe Set, 100:1, one red | On Request |
| Accessory Kits | Price List | | MA190 | MA190 Accessory kit for medical and video applications. | On Request |
| Automotive Accessories | Price List | | SCC198 | SCC198 Automotive Troubleshooting kit for 190 Series ScopeMeter | On Request |
| Batteries, Chargers and Adapters | Price List | | BC190 | BC190 Line Voltage Adapter / Battery Charger | On Request | | BHT190 | BHT190 – Break-out adapters for Industrial Bus connections | On Request | | BP190 | BP190 Rechargeable NiMH Battery Pack | On Request | | PM9082 | PM9082 Dual Banana Jack (female) to male BNC Adapter | On Request | | PM9093 | PM9093 Male BNC to Dual Female BNC Adapter | On Request |
| Cables and Hardware | Price List | | OC4USB | OC4USB USB interface cable | On Request | | PAC91 | PAC91 Printer Adapter Cable | On Request | | PM9091 | PM9091/001 Coaxial BNC cable set, color coded, 3 pcs, 1.5m each | On Request |
| Cases and Holsters | Price List | | C190 | C190 Hard Case (190 Series) | On Request | | C195 | C195 Soft Case | On Request | | C550 | C550 Tool Bag | On Request | | C75 | C75 Accessory Case | On Request | | Fluke MeterCleaner Wipes | Fluke MeterCleaner Wipes | On Request |
| Current clamps | Price List | | 80i-110s | 80i-110s AC/DC Current Probe (100 A) | On Request | | CS20MA | CS20MA Current Shunt, 4~20 mA, 30V CAT III | On Request | | i30s | Fluke i30s AC/DC Current Clamp | On Request | | i1000s | i1000s AC Current Clamp (1000 A) | On Request | | i1010 | i1010 AC/DC Current Clamp | On Request | | i200s | i200s AC Current Clamp | On Request | | i3000s | i3000s AC Current Clamp | On Request | | i3000s Flex-24 | i3000s Flex-24 AC Current Clamp, 610 mm (24 in.) | On Request | | i3000s Flex-36 | i3000s Flex-36 AC Current Clamp, 915 mm (36 in.) | On Request | | i310s | i310s Current Probe | On Request | | i400 | i400 AC Current Clamp | On Request | | i400s | i400s AC Current Clamp | On Request | | i410 | i410 AC/DC Current Clamp | On Request | | i5S | i5S AC Current Clamp | On Request |
| Options | Price List | | PM9081 | PM9081 Dual Banana Plug (male) to Female BNC Adapter | On Request |
| Software | Price List | | SW90W | SW90W FlukeView ScopeMeter Software | On Request |
| Pressure | Price List | | PV350 | PV350 Pressure Vacuum Module | On Request |
|
|
|
|
|
|
|
|
|
|
|
|
| | |