|
|
|
Two powerful tools in one
The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
Whether you work on motors, generators, cables, or switch gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to help you with your tasks and at a cost that is far less than buying the two products.
|
 |
Consult the features included on the two new insulation multimeters in the comparison chart below to help select the best tool for your application: |
| Feature |
1587 |
1577 |
| Insulation test voltages 50V, 100V, 250V, 500V, 1000V |
• |
|
| Insulation test voltages 500V, 1000V |
|
• |
| Insulation test: 0.01 MΩ to 2.0 GΩ |
• |
|
| Insulation test: 0.1 MΩ to 600 MΩ |
|
• |
| Auto discharge of capacitive voltage |
• |
• |
| Insulation test smoothing reading |
• |
|
| Frequency |
• |
|
| Capacitance |
• |
|
| Diode test |
• |
|
| Temperature |
• |
|
| Min/Max |
• |
|
| Low pass filter (for work on VSD's) |
• |
|
| AC/DC Voltage |
• |
• |
| DC millivolts |
• |
• |
| AC/DC milliamps |
• |
• |
| Resistance (0.1 Ω to 50 MΩ) |
• |
• |
| Continuity |
• |
• |
| Three-year warranty |
• |
• |
| Remote probe, test leads, alligator clips |
• |
• |
| K-type thermocouple |
• |
|
| Rugged, utility hard case |
• |
• |
| Auto power off to save battery power |
• |
• |
| True-rms |
• |
• |
| Large display with backlight |
• |
• |
| Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection |
• |
• |
| CAT III 1000V, CAT IV 600V measurement category |
• |
• |
| Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work |
• |
• |
|
|
|
| Specifications |
| Voltage DC |
| Maximum Voltage: |
1000 V |
| Accuracy: |
1577: ±(0.2%+2) |
|
1587: ±(0.09%+2) |
| Maximum Resolution: |
0.001V |
| | Voltage AC |
| Maximum Voltage: |
1000 V |
| Accuracy: |
1577: ±(2%+3) |
|
1587: ±(2%+3) |
| AC Bandwidth: |
1587: 5kHz* |
|
*with low pass filter; 3db @ 800 Hz |
| Maximum Resolution: |
0.1 mV |
| | Current DC |
| Maximum Amps: |
400mA |
| Amps Accuracy: |
1577: ±(1.0%+2) |
|
1587: ±(0.2%+2) |
| Maximum Resolution: |
0.01 mA |
| | Current AC |
| Maximum Amps: |
400mA |
| Amps Accuracy: |
1577: ±(2.0%+2)* |
|
1587: ±(1.5%+2)* |
|
* 1kHz bandwidth |
| Maximum Resolution: |
0.01 mA |
| | Resistance |
| Maximum Resistance: |
50 MΩ |
| Accuracy: |
1577: ±(1.2%+2) |
|
1587: ±(0.9%+2) |
| Maximum Resolution: |
0.1Ω |
| | Capacitance(1587 only) |
| Maximum Capacitance: |
9,999 µF |
| Accuracy: |
±(1.2%+2) |
| Maximum Resolution: |
1 nF |
| | Frequency (1587 only) |
| Maximum Frequency: |
100 kHz |
| Accuracy: |
±(0.1%+1) |
| Maximum Resolution: |
0.01 Hz |
| | Temperature Measurement (1587 only) |
|
-40.0 °C to 537 °C |
|
-40.0 °F to 998 °F |
|
excluding probe |
| | Diode Test (1587 only) |
| Range: |
6 V |
| Resolution: |
1 mV |
| Accuracy: |
±(2 % + 1) |
|
| Insulation Test |
| Minimum Test Current @ 1kΩ/V: | | | Test Voltages: |
| 1577: |
500, 1000 V |
| 1587: |
50, 100, 250, 500, 1000 V |
| | Maximum Resistance per Test Voltage: |
| 50V: |
|
| 100V: |
|
| 250V: |
|
| 500V: |
|
| 1000V: |
1577: 600 MΩ |
|
1587: 2 GΩ |
| | Maximum Resolution per Test Voltage: |
| 50V: |
0.01 MΩ |
| 100V: |
0.01 MΩ |
| 250V: |
0.1 MΩ |
| 500V: |
0.1 MΩ |
| 1000V: |
0.1 MΩ |
| | Accuracy per Test Voltage: |
| 50V: |
±(3 % + 5) |
| 100V: |
±(3 % + 5) |
| 250V: |
±(1.5 % + 5) |
| 500V: |
1577: ±(2.0 % + 5) |
|
1587: ±(1.5 % + 5) |
| 1000V: |
1577: ±(2.0 % + 5) |
|
1587: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ |
|
| Environmental Specifications |
| Operating temperature | | | Storage temperature | | | Humidity (Without Condensation) |
|
0% - 95% (10 °C – 30 °C) |
|
0% - 75% (30 °C – 40 °C) |
|
0% - 40% (40 °C – 55 °C) |
| | Operating Altitude | |
| Safety Specifications |
| Overvoltage category |
|
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
| | Agency Approvals |
|
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
|
| Mechanical & General Specifications |
| Size |
|
203 x 100 x 50 mm (with holster) |
| | Weight | | | Warranty | | | Battery life Alkaline |
| Meter use: |
1000 hours |
| Insulation test use: |
Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
| | IP Rating | |
|
| Model Name | Description | Price List | | Fluke 1587 |
Insulation Multimeter
Includes:
- Remote probe
- Test leads
- Alligator clips
- K-type thermocouple
- Hard case
- Four AA alkaline batteries
- Quick Reference Guide
- CD Rom with Manual
|
| On Request | | Fluke 1577 |
Insulation Multimeter
Includes:
- Remote probe
- Test leads
- Alligator clips
- Hard case
- Four AA alkaline batteries
- Quick Reference Guide
- CD Rom with Manual
|
| On Request |
| Clips | Price List | | AC285 | AC285 SureGrip™ Alligator Clip Set | On Request |
| Test Probes | Price List | | TP220 | TP220 SureGrip™ Industrial Test Probes | On Request |
| Cases and Holsters | Price List | | C101 | C101 Hard Case | On Request | | C25 | C25 Soft Meter Case | On Request | | C550 | C550 Tool Bag | On Request | | CXT170 | CXT170 Extreme Case | On Request | | Fluke MeterCleaner Wipes | Fluke MeterCleaner Wipes | On Request | | TPAK | TPAK ToolPak, Meter Hanging Kit | On Request |
| Current clamps | Price List | | i1010 Kit | i1010-KIT AC/DC Current Clamp and Carry Case Kit | On Request | | i200 | i200 AC Current Clamp | On Request | | i400 | i400 AC Current Clamp | On Request |
| Lights | Price List | | L200 | L200 Probe Light | On Request | | L210 | L210 Probe Light + Probe Extender | On Request | | LVD1 | LVD1 Volt Light | On Request |
| Temperature | Price List | | 80AK-A | 80AK-A Thermocouple Adapter | On Request | | 80PK-27 | 80PK-27 Industrial Surface Probe | On Request | | 80PK-3A | 80PK-3A Surface Probe (Type K) | On Request | | 80PK-8 | 80PK-8 Pipe Clamp Temperature Probe (Type K) | On Request |
| Test Leads | Price List | | TL27 | TL27 Heavy Duty Test Lead Set | On Request | | TL225 | TL225 SureGrip™ Stray Voltage Adapter Test Lead Kit | On Request |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|