Australia [Change Country]  |  Fluke [Change Company]
fluke
Home  |  Products  |  Digital Multimeters  |  
Contact usRefer this page

Fluke 117 Electrician's Multimeter with Non-Contact voltage

Contact Me
Request A Demo
 Fluke 117

Designed by electricians. Engineered by Fluke.

Compact true-rms meter for commercial applications. The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster.

Also check out the Fluke 114 Electrical Multimeter, the Fluke 115 Multimeter, and the Fluke 116 HVAC Multimeter with Temperature and Microamps.

Fluke 117 Electrical Multimeter in Use

 

  • VoltAlert™ technology for non-contact voltage detection
  • AutoVolt automatic ac/dc voltage selection
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • True-rms for accurate measurements on non-linear loads
  • Measures 10 A (20 A overload for 30-seconds)
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™) for hands free operation
  • CAT III 600 V safety rated

Specifications
Maximum voltage between any terminal and earth ground
 600 V
Surge protection
 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A input
 11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
 33 segments, updates 32 per second
Operating Temperature
 -10 °C to + 50 °C
Storage Temperature
 -40 °C to + 60 °C
Battery type
 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
 400 hours typical, without backlight

Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:  600.0 V
Resolution:  0.1 V
Accuracy:  2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  5 % + 2
Diode Test
Range/Resolution:  2.000 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 μF / 0.01 μF
Range/Resolution:  100.0 μF / 0.1 μF
Range/Resolution:  9999 μF / 1 μF
Range/Resolution:  100 μF to 1000 μF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 μF
Accuracy:  5% + 20%
LoZ capacitance
Range:  1 nF to 500 μF
Accuracy:  10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.5% + 3
 20 A continuous overload for 30 seconds max
DC amps
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.0% + 3
 20 A continuous overload for 30 seconds max
Hz (V or A input)2
Range/Resolution:  99.99 Hz / 0.01 Hz
Range/Resolution:  999.99 Hz / 0.1 Hz
Range/Resolution:  9.999 Hz / 0.001 Hz
Range/Resolution:  50.00 Hz / 0.01 Hz
Accuracy:  0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

Mechanical & General Specifications
Size
 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight
 550 g
Warranty
 3 years
Model NameDescription
Fluke 117 Electrician’s Multimeter with Non-Contact Voltage

Model includes the following:

  • 4 mm silicone test lead set
  • Holster
  • User manual

Clips
AC285AC285 SureGripTM Alligator Clips
AC87AC87 Heavy Duty Bus Bar Clip Set

Cases and Holsters
C50C50 Meter Case
C90C90 soft case for DMMs and visual IR thermometers
CXT170CXT170 Extreme Case
TPAK

Fluke TPAK ToolPakTM Magnetic Meter Hanger Kit includes:

  • 9 inch hook and loop strap
  • Universal hanger clip
  • Hook hanger for non magnetic surfaces
  • Strong magnet

Current Clamps
i400si400s AC Current Clamp

Lights
L206L206 Deluxe LED Hat Light
LVD1LVD1 Volt Light

Temperature
80PK-980PK-9 General Purpose Probe
80TK80TK Thermocouple Module

Test Leads
TL220

SureGrip™ Industrial Test Lead Set includes:

  • AC220 SureGrip™ Alligator Clip Set
  • TP238 SureGrip™ Insulated Test Probe Set
  • TL222 SureGrip™ Silicone Test Lead Set (right to right)
  • One year warranty