 Fluke 724 – Calibrador De Temperatura
Built for the masters of temperature.

The Fluke 724: everything you need to troubleshoot and calibrate temperature.

  • Now you can carry one tool to expertly test all the temperature sensors and transmitters in your plant.
  • The Fluke 724 is the master’s answer to temperature calibration. The Fluke 724 can measure and source 10 thermocouple types and 7 RTD types, plus volts and ohms.
  • The Fluke 724 even handles high-speed pulsed RTD circuits and provides loop power.
  • The dual line measure/source display lets you source temperature and view loop current at the same time.
  • With its simple, “no menus controls, the Fluke 724 is easy to operate, too.
Feel the Heat!
The new Fluke 724 Temperature Calibrator is a powerful yet easy-to-use calibrator. Use the measure and source functions to test and calibrate almost any temperature instrument.
  • Easy to read dual display lets you view input and output simultaneously
  • Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters
  • Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters
  • Perform fast linearity tests with 25% and 100% steps
  • Execute remote tests with auto step and auto ramp
  • Power transmitters during test using loop power supply with simultaneous mA measurement
  • Store frequently-used test setups for later use
  • Compact, streamlined shape makes it easy to carry
  • Rugged, reliable design stands up to field use
  • Backlight lets you work in poor light
  • Large battery capacity of four AA cells
  • Battery door for easy changes
Measurement Accuracy
Voltage DC
30.000 V  0.02%+ 2 counts (upper display)
20.000 V  0.02%+ 2 counts (lower display)
100.00 mV  0.02%+ 2 counts
-10.00 mV to 75.00 mV  0.025 % + 1 count (via TC connector)
Current DC
24.000 mA  0.02%+ 2 counts
Resistance
0.0 to 400.0 Ω  0.1Ω (4-wire), 0.15Ω (2- and 3-wire)
401 to 1500 Ω  0.5Ω (4-wire), 1Ω (2- and 3-wire)
1500 to 3200 Ω  1Ω (4-wire), 1.5Ω (2- and 3-wire)

Source Accuracy
Voltage DC
100.00 mV  0.02%+2 counts
10.000 V  0.02%+2 counts
-10.00 mV to 75.00 mV  0.025 % + 1 count (via TC connector)
Resistance
15.0 to 400.0 Ω  0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
401 to 1500 Ω  0.5 Ω(excitation current 0.05 to 0.8 mA)
1500 to 3200 Ω  1 Ω(excitation current 0.05 to 0.4 mA)

RTDs and Thermocouples
Measure Accuracy:
NI-120  0.2 °C
PT-100 (385)  0.33 °C
PT-100 (393)  0.3 °C
PT-100 (JIS)  0.3 °C
PT-200 (385)  0.2 °C
PT-500 (385)  0.3 °C
PT-1000 (385)  0.2 °C
Resolution:  0.1 °C
J:  0.7 °C
K:  0.8 °C
T:  0.8 °C
E:  0.7 °C
R:  1.8 °C
S:  1.5 °C
B:  1.4 °C
L:  0.7 °C
U:  0.75 °C
N:  0.9°C
Resolution  J, K, T, E, L, N, U: 0.1 °C, 0.1 °F B, R, S: 1 °C, 1 °F
XK  0.6°C
BP  1.2°C
Source Accuracy:
NI-120  0.2 °C
PT-100 (385)  0.33 °C
PT-100 (393)  0.3 °C
PT-100 (JIS)  0.3 °C
PT-200 (385)  0.2 °C
PT-500 (385)  0.3 °C
PT-1000 (385)  0.2 °C
Resolution:  0.1 °C
Note:  Accuracy stated for 4-wire measurement.
J:  0.7 °C
K:  0.8 °C
T:  0.8 °C
E:  0.7 °C
R:  1.4 °C
S:  1.5 °C
B:  1.4 °C
L:  0.7 °C
U:  0.75 °C
N:  0.9 °C
Resolution  J, K, T, E, L, N, U: 0.1 °C, B, R, S: 1 °C
XK  0.6°C
BP  1.2°C

Specifications
Ramp Functions
Source functions:  Voltage, current, resistance, frequency, temperature
Ramps  Slow ramp, Fast ramp, 25% step-ramp
Loop Power Function
Voltage:  24V
Accuracy:  10%
Maximum current:  22 mA, short circuit protected
Step Functions
Source functions:  Voltage, current, resistance, frequency, temperature
Steps  25% of range, 100% of range

Environmental Specifications
Operating Temperature
 -10ºC to 55ºC
Storage Temperature
 -20ºC to 71ºC
Humidity (Without Condensation)
90%  10ºC to 30ºC
75%  30ºC to 40ºC
45%  40ºC to 50ºC
35%  50ºC to 55ºC

Safety Specifications
Safety Rating
 CSA C22.2 No. 1010.1:1992
EMC
 EN50082-1:1992 and EN55022:1994 Class B

Mechanical & General Specifications
Size
 96 x 200 x 47 mm
Weight
 650 g
Batteries
 Four AA alkaline batteries.
Warranty
 Three years
Battery Life
 25 hours typical
Shock & Vibration
 Random, 2G, 5-500 Hz
Nombre del modeloDescripción
Fluke 724 Temperature Calibrator including:
  • AC70A Test Clips
  • One pair of stackable test leads
  • TL75 Test Leads
  • CE and CSA Markings
  • Manuals in English, French, German, Spanish, Italian, Portugese, Korean, Chinese and Japanese
  • Users manuals on CD-ROM
  • NIST- traceable calibration report and data

Clips
AC220AC220 Juego de pinzas de cocodrilo SureGrip™
AC280AC280 Jeugo de pinzas de gancho SureGrip™
AC283AC283 Juego de pinzas SureGrip™
AC87AC87 Pinzas de cocodrilo de ángulo recto
AC285Pinzas de cocodrilo AC285 SureGrip™
AC89Pinzas de prueba penetrante de aislamiento, robustas AC89

Puntas de prueba
TP1TP1 Puntas de prueba extrafina (hoja plana)
TP2TP2 Puntas de prueba extrafina (2 mm)
TP38TP38 Puntas de prueba extrafina (aislada)
TP74TP74 Puntas de prueba de tipo linterna

Estuches y fundas
C100C100 Estuche rígido para multímetro y accesorios
C125C125 Estuche flexible
C510C510 Estuche de cuero para multímetro
C550C550 Bolsa de herramientas
CXT80Maletín de gran resistencia CXT80
TPAKTPAK ToolPak, juego de accesorios para colgar el multímetro

Linternas
L206L206 Luz LED de lujo para casco
LVD1Linterna detector de tensión LVD1

Cables de prueba
TL238Juego de cables de prueba , modelo TL238 SureGrip™ para entornos de alta tensión
TL220TL220 Juego de cables de prueba industriales SureGrip™
TL221TL221 Juego de cables de extensión SureGrip™
TL222TL222 Juego de cables de prueba de silicona SureGrip™
TL223TL223 Juego de cables eléctricos SureGrip™
TL224TL224 Juego de cables de prueba de silicona SureGrip™
TL27TL27 Juego de cables robustos
TL71TL71 Juego de cables de prueba
TL76TL76 Juego de puntas de prueba completo
TL81ATL81A Juego de cables de prueba Deluxe para aplicaciones electrónicas

Temperatura
700TC2700TC2 Juegos de clavijas de termopar (5 tipos)
80CJ-M80CJ-M Miniconectores macho (tipo J)
80CK-M80CK-M Miniconectores macho (tipo K)
80PJ-180PJ-1 Sonda de extremo redondeado (tipo K)
80PJ-EXT80PJ-EXT Juego de cables de extensión (tipo J)
80PK-180PK-1 Sonda de extremo redondeado (tipo K)
80PK-2280PK-22 Sonda de inmersión
80PK-2480PK-24 Sonda de aire
80PK-2580PK-25 Sonda penetrante
80PK-2680PK-26 Sonda de propósito general
80PK-2780PK-27 Sonda industrial de superficie
80PK-3A80PK-3A Sonda de superficie (tipo K)
80PK-880PK-8 Sonda de temperatura para tuberías (tipo K)
80PK-980PK-9 Sonda de propósito general (tipo K)
80PK-EXT80PK-EXT Juego de cables de extensión (tipo K)
80PT-EXT80PT-EXT Juego de cables de extensión (tipo T)
Medidor de Aislamiento | Prueba de resistencia de aislamiento | Detector de tensión
Comprobador de corriente | VoltAlert | Pinza amperimétrica | Pinza de corriente
Termómetros | Termómetros de control de alimentos | Minitermómetros de infrarrojos
Termómetros por infrarrojos | Termómetros por infrarrojos
Home  |   Mapa del Sitio  |   Fluke Corporation  |   Avisos de Seguridad
Declaración de privacidad  |   Términos de Uso   |   Términos y Condiciones
© 1995 - 2014 Fluke Corporation