English

Product selection guide: Clamp meters

Use our product selection guide to find the clamp meter that fits your needs best.
RemoveRemove
Fluke 365 Detachable Jaw True RMS AC/DC Clamp Meter
Fluke 355 True RMS 2000 A Clamp Meter
Fluke 365 Detachable Jaw True RMS AC/DC Clamp MeterFluke 355 True RMS 2000 A Clamp Meter
Category ratingsCAT III 600 VCAT III 1000 V, CAT IV 600 V 
Flashlight / torch  
Inrush current mode  
Low-pass filter  
Jaw opening0.7 in (18 mm)2.3 in 
Max wire size (MCM)3502000+ 
Current range AC (RMS)200.0 A1400 A 
AC responseTrue RMSTrue RMS 
Current range DC200 A2000 A 
Accuracy DC current: ± 5 counts2.00 %1.50 % 
Voltage range AC600 V600 V 
Accuracy AC voltage: ± 5 counts1.50 %1.00 % 
Resistance range6000 Ω400 kΩ 
Accuracy AC current (50/60 Hz): ± 5 counts2.00 %1.50 % 
Voltage range DC600 V1000 V 
Accuracy DC voltage: ± 5 counts1.00 %1.00 % 
Frequency measurement range5 to 1000 Hz 
Auto off   
AC current   
AC voltage   
Resistance   
Continuity   
DC volts   
DC current   
True RMS   
Frequency  
AC + DC voltage  
AC + DC current  
Min-Max-Avg  
Display hold   